Shuo Liu

Dr. Shuo Liu

Peking University, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLShuo Liu
Shuo Liu
YWYaxia Wei
Yaxia Wei
YLYuanrong Lu
Yuanrong Lu
ZWZhi Wang
Zhi Wang
MHMeiyun Han
Meiyun Han
PZPengfei ZHENG
Pengfei ZHENG
In order to figure out the migration and deposition of impurities on the first wall of HL-2A/2M tokamak, Peking University and Southwestern Institute of Physics are co-developing a deuteron RFQ as part of the in situ ion-beam diagnostic for the material. The RFQ, which operates at 162.5 MHz, is designed to accelerate a 10-mA deuteron beam from 40 keV up to 1.5 MeV. Key design considerations and the final design parameters are presented. The RFQ has been conditioned at a 1% duty factor for 80 h at RF cavity power of 55 kW. The specific shunt impedance of the cavity is 221 kΩ·m by measuring the bremsstrahlung spectrum. The intrinsic Q-value after the high-power tests measured by the Ring-Down method is 13,780. Beam commissioning has been taken place during the first half of 2021, and the beam measurements include beam current and energy of 2H+ ion. A 10 mA 2H+ beam was successfully accelerated through the RFQ.

2 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMeiyun Han
Meiyun Han
YLYuanrong Lu
Yuanrong Lu
ZWZhi Wang
Zhi Wang
ZPZhaohua Peng
Zhaohua Peng
SLShuo Liu
Shuo Liu
YXYing Xia
Ying Xia
Based on the latest design requirements proposed by the Beijing On-Line Isotope Separation (BISOL) project, a new Sn22+-based, 81.25 MHz CW radio frequency quadrupole (RFQ) with external bunching has been designed. This RFQ can accelerate Sn22+ to 0.5 MeV/u with an output longitudinal-normalized rms emittance of 0.20 keV/u·ns over a length of 5.6 m. The tolerance and error analysis results indicate that this RFQ can handle a wide range of non-ideal beams while maintaining relatively lower longitudinal emittance growth and higher transmission efficiency. To maintain the beam intensity, the RFQ will simultaneously accelerate three kinds of high-charge-state mixed ions (132Sn21+, 132Sn22+ and 132Sn23+), the simulation results given by Impact-T show that the RFQ can achieve high transmission of the mixed beam. Compared with the previous Sn21+-based internal bunching RFQ scheme, this RFQ has a shorter length and smaller output emittance, which is beneficial to the designs of subsequent Medium-energy Beam Transport (MEBT) and Drift Tube Linac (DTL). In electromagnetic design, a four-vane structure with 48 tuners and 16 π-mode stabilizers (PSLs) were chosen. The results of the multi-physics analysis show that the maximum temperature rise and the maximum deformation of the cavity are 13.6 K and 40.3 µm, respectively. The results simulated with CST Microwave Studio (CST) and HFSS software were consistent.

25 March 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SLShuo Liu
Shuo Liu
JSJ. Shi
J. Shi
TWT. H. Wei
T. H. Wei
CWC. P. Wang
C. P. Wang
TRT. H. Rui
T. H. Rui
YLY. R. Lu
Y. R. Lu
This paper presents the design of a compact injector linac for heavy ion medical therapy, based on a 200 MHz radio frequency quadrupole (RFQ) and two 200 MHz interdigit H-mode drift tube linac (IH-DTL) tanks using the KONUS beam dynamics scheme. In this system, the RFQ accelerates a 12C4+ beam from 10 keV/u to 0.6 MeV/u, after which it is further accelerated to 7 MeV/u by two IH-DTL tanks. The design specifically aims to improve transmission efficiency, minimize emittance growth, and reduce the overall system length. A three-bunching-cell structure at the RFQ exit provides longitudinal beam focusing, effectively eliminating the need for a separate re-buncher and significantly shortening the MEBT section. The linac achieves a compact total length of approximately 8.6 m and requires a total peak RF power of 774 kW. The peak surface field in the IH-DTL cavities reaches 2.0 Kp, while the effective shunt impedances are 110 MΩ/m and 126 MΩ/m for the first and second tanks, respectively. End-to-end simulations confirm high transmission and good beam quality at the linac exit, demonstrating the suitability of the design for synchrotron injection in medical applications.