Prosper Obaro Oyibo

Mr. Prosper Obaro Oyibo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
POProsper Obaro Oyibo
Prosper Obaro Oyibo
SJSatyajith Jujjavarapu
Satyajith Jujjavarapu
BMBrice Meulah
Brice Meulah
TATope Ebenzer Agbana
Tope Ebenzer Agbana
IBIngeborg Braakman
Ingeborg Braakman
JDJan Carel Diehl
Jan Carel Diehl
For many parasitic diseases, the microscopic examination of clinical samples such as urine and stool still serves as the diagnostic reference standard, primarily because microscopes are accessible and cost-effective. However, conventional microscopy is laborious, requires highly skilled personnel, and is highly subjective. Requirements for skilled operators, coupled with the cost and maintenance needs of the microscopes, which is hardly done in endemic countries, presents grossly limited access to the diagnosis of parasitic diseases in resource-limited settings. The urgent requirement for the management of tropical diseases such as schistosomiasis, which is now focused on elimination, has underscored the critical need for the creation of access to easy-to-use diagnosis for case detection, community mapping, and surveillance. In this paper, we present a low-cost automated digital microscope—the Schistoscope—which is capable of automatic focusing and scanning regions of interest in prepared microscope slides, and automatic detection of Schistosoma haematobium eggs in captured images. The device was developed using widely accessible distributed manufacturing methods and off-the-shelf components to enable local manufacturability and ease of maintenance. For proof of principle, we created a Schistosoma haematobium egg dataset of over 5000 images captured from spiked and clinical urine samples from field settings and demonstrated the automatic detection of Schistosoma haematobium eggs using a trained deep neural network model. The experiments and results presented in this paper collectively illustrate the robustness, stability, and optical performance of the device, making it suitable for use in the monitoring and evaluation of schistosomiasis control programs in endemic settings.

17 October 2022 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Open access
PDF file
BMBrice Meulah
Brice Meulah
POProsper Obaro Oyibo
Prosper Obaro Oyibo
MBMichel Bengtson
Michel Bengtson
TATope Ebenzer Agbana
Tope Ebenzer Agbana
RLRoméo Aimé Laclong Lontchi
Roméo Aimé Laclong Lontchi
LVLisette Van
Lisette Van
: Conventional microscopy is the standard procedure for the diagnosis of schistosomiasis, despite its limited sensitivity, reliance on skilled personnel, and the fact that it is error prone. Here, we report the performance of the innovative (semi-)automated Schistoscope 5.0 for optical digital detection and quantification of Schistosoma haematobium eggs in urine, using conventional microscopy as the reference standard. At baseline, 487 participants in a rural setting in Nigeria were assessed, of which 166 (34.1%) tested S. haematobium positive by conventional microscopy. Captured images from the Schistoscope 5.0 were analyzed manually (semiautomation) and by an artificial intelligence (AI) algorithm (full automation). Semi- and fully automated digital microscopy showed comparable sensitivities of 80.1% (95% confidence interval [CI]: 73.2–86.0) and 87.3% (95% CI: 81.3–92.0), but a significant difference in specificity of 95.3% (95% CI: 92.4–97.4) and 48.9% (95% CI: 43.3–55.0), respectively. Overall, estimated egg counts of semi- and fully automated digital microscopy correlated significantly with the egg counts of conventional microscopy (r = 0.90 and r = 0.80, respectively, P < 0.001), although the fully automated procedure generally underestimated the higher egg counts. In 38 egg positive cases, an additional urine sample was examined 10 days after praziquantel treatment, showing a similar cure rate and egg reduction rate when comparing conventional microscopy with semiautomated digital microscopy. In this first extensive field evaluation, we found the semiautomated Schistoscope 5.0 to be a promising tool for the detection and monitoring of S. haematobium infection, although further improvement of the AI algorithm for full automation is required.

1 July 2023 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
POProsper Obaro Oyibo
Prosper Obaro Oyibo
BMBrice Meulah
Brice Meulah
MBMichel Bengtson
Michel Bengtson
LVLisette Van
Lisette Van
WOWellington Aghoghovwia Oyibo
Wellington Aghoghovwia Oyibo
TATope Ebenzer Agbana
Tope Ebenzer Agbana
Schistosomiasis is endemic in 76 countries worldwide with ∼252  million people infected and an estimated 779 million people at risk of infection.1 Schistosomiasis is caused by blood flukes of the genus Schistosoma (S); both S. mansoni (intestinal schistosomiasis) and S. haematobium (urogenital schistosomiasis) are endemic in Africa.2 Schistosomiasis presents a substantial public health and economic burden as it is a disease of poverty. In the drive to attain the World Health Organization (WHO) control and elimination targets, diagnosis for adequate monitoring of interventions and surveillance is critical.2,3 Recently, the WHO published the diagnostic target product profiles (TPP) for monitoring, evaluation, and surveillance of schistosomiasis control programs,4 which identifies development of diagnostic tests for S. haematobium detection as a high-risk requirement due to lack of its availability. The TPP suggests a semi-quantitative analysis, capable of providing some degree of information regarding intensity of infection, as ideal for a diagnostic test for schistosomiasis to support monitoring and evaluation.4 Currently, microscopy is the WHO reference standard for the diagnosis of schistosomiasis in resource-limited settings. For the detection of S. haematobium infection, urine samples, after filtration, sedimentation, or centrifugation, are microscopically examined for the presence of eggs.3 This method is operator dependent, costly, laborious, and time-consuming. Furthermore, it requires expertise, which means microscopy skills need to be gained and maintained, which can be an economic challenge, particularly in remote rural communities.3 There is also the risk of visual health complications among microscopists resulting from excessive workload due to the low ratio of trained microscopists to samples for analysis in endemic regions.5 Hence, a field adaptable, rapid, and easy-to-use automated diagnosis is relevant for the prompt detection of cases, which will facilitate mapping and monitoring of interventions.4 Recent advances in opto-mechanics and opto-electronics have rapidly transformed the field of biomedical optics. Optical imaging technologies, such as conventional light microscopes, are being redesigned to integrate and miniaturize portable light microscopes for use at the point of care.6 – 9 Although these technologies are readily available in high-income countries, unfortunately, nearly all schistosomiasis cases are seen in low-resource regions of low-income countries, significantly justifying the need for cost-effective and easy-to-use smart diagnostic technologies. In this work, we address these challenges by first increasing the size of the S. haematobium (SH) dataset in our previous work10 from 5198 to 12,051 images of clinical samples.11 We carry out detection and counting of S. haematobium eggs present in each image by proposing a two-stage framework consisting of a DeepLabv3 with MobilenetV3 backbone deep convolutional neural network12 trained on the SH dataset using a transfer learning approach. The second stage of our proposed framework is a refined segmentation and egg counting procedure, which adapts the region-based fitting of overlapping ellipses13 to efficiently separate the boundaries of overlapping eggs in the image. Finally, the detected isolated eggs are screened for the presence of an egg, which meets the defined boundary condition before the sample can be determined as positive/negative diagnosis. We further demonstrate the robustness and applicability of the proposed framework for field diagnoses of urogenital schistosomiasis by implementing our framework on an Edge AI system (Raspberry Pi + Coral USB accelerator) and testing 65 clinical urine samples obtained in a field settings in Nigeria. The main contributions of this work can be summarized as follows.

30 January 2024 in Journal of Microscopy
Verified
Journal Article
Open access
POProsper Obaro Oyibo
Prosper Obaro Oyibo
TATope Agbana
Tope Agbana
LLLisette van Lieshout
Lisette van Lieshout
WOWellington Oyibo
Wellington Oyibo
JDJan Carel Diehl
Jan Carel Diehl
GVGleb Vdovine
Gleb Vdovine
Traditionally, automated slide scanning involves capturing a rectangular grid of field‐of‐view (FoV) images which can be stitched together to create whole slide images, while the autofocusing algorithm captures a focal stack of images to determine the best in‐focus image. However, these methods can be time‐consuming due to the need for X‐, Y‐ and Z‐axis movements of the digital microscope while capturing multiple FoV images. In this paper, we propose a solution to minimise these redundancies by presenting an optimal procedure for automated slide scanning of circular membrane filters on a glass slide. We achieve this by following an optimal path in the sample plane, ensuring that only FoVs overlapping the filter membrane are captured. To capture the best in‐focus FoV image, we utilise a hill‐climbing approach that tracks the peak of the mean of Gaussian gradient of the captured FoVs images along the Z‐axis. We implemented this procedure to optimise the efficiency of the Schistoscope, an automated digital microscope developed to diagnose urogenital schistosomiasis by imaging Schistosoma haematobium eggs on 13 or 25 mm membrane filters. Our improved method reduces the automated slide scanning time by 63.18% and 72.52% for the respective filter sizes. This advancement greatly supports the practicality of the Schistoscope in large‐scale schistosomiasis monitoring and evaluation programs in endemic regions. This will save time, resources and also accelerate generation of data that is critical in achieving the targets for schistosomiasis elimination.