This work analyzes the results of measurements on thermal energy harvesting through a wearable Thermo-electric Generator (TEG) placed on the arms and legs. Four large skin areas were chosen as locations for the placement of the TEGs. In order to place the generator on the body, a special manufactured band guaranteed the proper contact between the skin and TEG. Preliminary measurements were performed to find out the value of the resistor load which maximizes the power output. Then, an experimental investigation was conducted for the measurement of harvested energy while users were performing daily activities, such as sitting, walking, jogging, and riding a bike. The generated power values were in the range from 5 to 50 μW. Moreover, a preliminary hypothesis based on the obtained results indicates the possibility to use TEGs on leg for the recognition of locomotion activities. It is due to the rather high and different biomechanical work, produced by the gastrocnemius muscle, while the user is walking rather than jogging or riding a bike. This result reflects a difference between temperatures associated with the performance of different activities.

1 January 2012 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
PDF file
ZSZdenek Slanina
Zdenek Slanina
VKVladimir Kasik
Vladimir Kasik
KMKarel Musil
Karel Musil

25 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DBDaniele Bibbo
Daniele Bibbo
TKTomas Klinkovsky
Tomas Klinkovsky
MPMarek Penhaker
Marek Penhaker
PKPetr Kudrna
Petr Kudrna
LPLukas Peter
Lukas Peter
DBDaniel Bielcik
Daniel Bielcik
In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother’s heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within ±3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses.

1 January 2009 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
PDF file
MAMartin Augustynek
Martin Augustynek
LĈLukáŝ Ĉajka
Lukáŝ Ĉajka
VKVladimir Kasik
Vladimir Kasik

1 January 2009 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
PDF file
VKVladimir Kasik
Vladimir Kasik