Sung Hyun Lee

Dr. Sung Hyun Lee

Yamagata University Hospital, Yamagata, Gifu, Japan
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Anticancer Research
Verified
Journal Article
Closed access
PDF file
SMShinnosuke Matsumoto
Shinnosuke Matsumoto
SLSung Hyun Lee
Sung Hyun Lee
RIReiko Imai
Reiko Imai
TITaku Inaniwa
Taku Inaniwa
NMNaruhiro Matsufuji
Naruhiro Matsufuji
NKNobuyuki Kanematsu
Nobuyuki Kanematsu
Background/Aim: The local control rate of chondrosarcomas treated with carbon-ion radiotherapy (CIRT) worsens as tumour size increases, possibly because of the intra-tumoural linear energy transfer (LET) distribution. This study aimed to evaluate the relationship between local recurrence and intra-tumoural LET distribution in chondrosarcomas treated with CIRT. Patients and Methods: Thirty patients treated with CIRT for grade 2 chondrosarcoma were included. Dose-averaged LET (LETd) distribution was calculated by the treatment planning system, and the relationship between LETd distribution in the planning tumour volume (PTV) and local control was evaluated. Results: The mean LETd value in PTV was similar between cases with and without recurrence. Recurrence was not observed in cases where the effective minimum LETd value exceeded 40 keV/μm. Conclusion: LETd distribution in PTV is associated with local control in chondrosarcomas and patients treated with ion beams of higher LETd may have an improved local control rate for unresectable chondrosarcomas.

1 February 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TITaku Inaniwa
Taku Inaniwa
MSMasao Suzuki
Masao Suzuki
SLSung Hyun Lee
Sung Hyun Lee
KMKota Mizushima
Kota Mizushima
YIYoshiyuki Iwata
Yoshiyuki Iwata
TSToshiyuki Shirai
Toshiyuki Shirai
The National Institute of Radiological Sciences (NIRS) has initiated a development project for hypo-fractionated multi-ion therapy. In the treatment, heavy ions up to neon ions will be used as a primary beam, which is a high linear energy transfer (LET) radiation. The fractionated dose of the treatment will be 10 Gy or more. The microdosimetric kinetic (MK) model overestimates the biological effectiveness of high-LET and high-dose radiations. To address this issue, the stochastic microdosimetric kinetic (SMK) model has been developed as an extension of the MK model. By taking the stochastic nature of domain-specific and cell nucleus-specific energies into account, the SMK model could estimate the biological effectiveness of radiations with wide LET and dose ranges. Previously, the accuracy of the SMK model was examined by comparison of estimated and reported survival fractions of human cells exposed to pristine helium-, carbon-, and neon-ion beams. In this study, we verified the SMK model in treatment planning of scanned helium-, carbon-, oxygen-, and neon-ion beams as well as their combinations through the irradiations of human undifferentiated carcinoma and human pancreatic cancer cells. Treatment plans were made with the ion-species beams to achieve a uniform 10% survival of the cells within a cuboid target. The planned survival fractions were reasonably reproduced by the measured survival fractions in the whole region from the plateau to the fragment tail for all planned irradiations. The SMK model offers the accuracy and simplicity required in hypo-fractionated multi-ion therapy treatment planning.

1 January 2015 in Radiation Oncology Journal
Verified
Journal Article
Open access
PDF file
EPEun Kyung Paik
Eun Kyung Paik
MKMi-Sook Kim
Mi-Sook Kim
CCChul Won Choi
Chul Won Choi
WJWon Il Jang
Won Il Jang
SLSung Hyun Lee
Sung Hyun Lee
DLDong Han Lee
Dong Han Lee
Paik EK, et al. Radiat Oncol J. 2015 Sep;33(3):233-241. http://dx.doi.org/10.3857/roj.2015.33.3.233

30 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LTLinh Tran
Linh Tran
DBDavid Bolst
David Bolst
BJBenjamin James
Benjamin James
VPVladimir Pan
Vladimir Pan
JVJames Vohradsky
James Vohradsky
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. 3D SVs were fabricated in different sizes and configurations with diameters between 18 and 30 µm, thicknesses of 2–50 µm and at a pitch of 50 µm in matrices with volumes of 20 × 20 and 50 × 50. SVs were segmented into sub-arrays to reduce capacitance and avoid pile up in high-dose rate pencil beam scanning applications. Detailed TCAD simulations and charge collection studies in individual SVs have been performed. The microdosimetry probe (MicroPlus) is composed of the silicon microdosimeter and low-noise front–end readout electronics housed in a PMMA waterproof sheath that allows measurements of lineal energies as low as 0.4 keV/µm in water or PMMA. Microdosimetric quantities measured with SOI microdosimeters and the MicroPlus probe were used to evaluate the relative biological effectiveness (RBE) of heavy ions and protons delivered by pencil-beam scanning and passive scattering systems in different particle therapy centres. The 3D detectors and MicroPlus probe developed for microdosimetry have the potential to provide confidence in the delivery of RBE optimized particle therapy when introduced into routine clinical practice.

22 October 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SPStefania Peracchi
Stefania Peracchi
BJBenjamin James
Benjamin James
FPFederico Pagani
Federico Pagani
VPVladimir Pan
Vladimir Pan
JVJames Vohradsky
James Vohradsky
LTLinh Tran
Linh Tran
Despite the low contribution of heavy ions to the total fluence in the space radiation environment, their radiobiological effect on the human body is extremely high. In this article, we investigated the radiation field which resulted from the interaction of galactic cosmic rays (GCRs), specifically some heavy ions and energies, typically encountered in space with a realistic multilayer sample of the International Space Station (ISS) Columbus module's shielding wall. The quality factor, Q, and the normalized dose equivalent, H, derived from microdosimetric measurements for C, Ne, and Si ions behind different spacecraft wall configurations and materials are presented in this article. Particularly, carbon fiber, polyoxymethylene, and perspex with same areal density compared to currently used aluminum were investigated.

8 February 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SLSung Hyun Lee
Sung Hyun Lee
KMKota Mizushima
Kota Mizushima
RKRyosuke Kohno
Ryosuke Kohno
YIYoshiyuki Iwata
Yoshiyuki Iwata
SYShunsuke Yonai
Shunsuke Yonai
TITaku Inaniwa
Taku Inaniwa
In this study, the survival fraction (SF) and relative biological effectiveness (RBE) of pancreatic cancer cells exposed to spread-out Bragg peak helium, carbon, oxygen, and neon ion beams are estimated from the measured microdosimetric spectra using a microdosimeter and the application of the microdosimetric kinetic (MK) model. To measure the microdosimetric spectra, a 3D mushroom silicon-on-insulator microdosimeter connected to low noise readout electronics (MicroPlus probe) was used. The parameters of the MK model were determined for pancreatic cancer cells such that the calculated SFs reproduced previously reported in vitro SF data. For a cuboid target of 10 × 10 × 6 cm 3 , treatment plans of helium, carbon, oxygen, and neon ion beams were designed using in-house treatment planning software (TPS) to achieve a 10% SF of pancreatic cancer cells throughout the target. The physical doses and microdosimetric spectra of the planned fields were measured at different depths in polymethyl methacrylate phantoms. The biological effects, such as SF, RBE, and RBE-weighted dose at different depths along the fields were predicted from the measurements. The predicted SFs at the target region were generally in good agreement with the planned SF from the TPS in most cases.