Anatoly B. Rosenfeld

Prof. Anatoly B. Rosenfeld

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2003 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
JHJohn L. Humm
John L. Humm
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
AGAlberto Del Guerra
Alberto Del Guerra

20 October 2010 in Medical Physics
Verified
Journal Article
Closed access
SPS. N. Penfold
S. N. Penfold
RSReinhard W Schulte
Reinhard W Schulte
YCY. Censor
Y. Censor
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

1 April 2015 in Journal of Archaeological Science
Verified
Journal Article
Closed access
RRRichard G. Roberts
Richard G. Roberts
ZJZenobia Jacobs
Zenobia Jacobs
BLBo Li
Bo Li
NJNathan R. Jankowski
Nathan R. Jankowski
ACAlastair C. Cunningham
Alastair C. Cunningham
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

1 February 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld

1 November 1998 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Tomas KronTomas Kron
Tomas Kron
LDLisa Duggan
Lisa Duggan
TSTony Smith
Tony Smith
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
MBMartin Butson
Martin Butson
KHKazuyuki Hyodo
Kazuyuki Hyodo
Accurate dosimetry is particularly difficult for low- to medium-energy x-rays as various interaction processes with different dependences on material properties determine the dose distribution in tissue and radiation detectors. Monoenergetic x-rays from synchrotron radiation offer the unique opportunity to study the dose response variation with photon energy of radiation detectors without the compounding effect of the spectral distribution of x-rays from conventional sources. The variation of dose response with photon energies between 10 and 99.6 keV was studied for two TLD materials (LiF:Mg,Ti and LiF:Mg,Cu,P), MOSFET semiconductors, radiographic and radiochromic film. The dose response at synchrotron radiation energies was compared with the one for several superficial/orthovoltage radiation qualities (HVL 1.4 mm Al to 4 mm Cu) and megavoltage photons from a medical linear accelerator. A calibrated parallel plate ionization chamber was taken as the reference dosimeter. The variation of response with x-ray energy was modelled using a two-component model that allows determination of the energy for maximum response as well as its magnitude. MOSFET detectors and the radiographic film were found to overrespond to low-energy x-rays by up to a factor of 7 and 12 respectively, while the radiochromic film underestimated the dose by approximately a factor of 2 at 24 keV. The TLDs showed a slight overresponse with LiF:Mg, Cu, P demonstrating better tissue equivalence than LiF:Mg, Ti (maximum deviation from water less than 25%). The results of the present study demonstrate the usefulness of monoenergetic photons for the study of the energy response of radiation detectors. The variations in energy response observed for the MOSFET detectors and GAF chromic film emphasize the need for a correction for individual dosimeters if accurate dosimetry of low- to medium-energy x-rays is attempted.

1 September 2015 in Physica Medica
Verified
Journal Article
Open access
EBElke Bräuer-Krisch
Elke Bräuer-Krisch
JAJean-Francois Adam
Jean-Francois Adam
EAEnver Alagoz
Enver Alagoz
Stefan BartzschStefan Bartzsch
Stefan Bartzsch
JCJeff Crosbie
Jeff Crosbie
BSBjarne Stugu
Bjarne Stugu
Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. Although the techniques differ by their principles, SSRT and MRT share certain common aspects with the possibility of combining their advantages in the future. For MRT, the technique uses highly collimated, quasi-parallel arrays of X-ray microbeams between 50 and 600 keV. Important features of highly brilliant Synchrotron sources are a very small beam divergence and an extremely high dose rate. The minimal beam divergence allows the insertion of so called Multi Slit Collimators (MSC) to produce spatially fractionated beams of typically ∼25-75 micron-wide microplanar beams separated by wider (100-400 microns center-to-center(ctc)) spaces with a very sharp penumbra. Peak entrance doses of several hundreds of Gy are extremely well tolerated by normal tissues and at the same time provide a higher therapeutic index for various tumor models in rodents. The hypothesis of a selective radio-vulnerability of the tumor vasculature versus normal blood vessels by MRT was recently more solidified. SSRT (Synchrotron Stereotactic Radiotherapy) is based on a local drug uptake of high-Z elements in tumors followed by stereotactic irradiation with 80 keV photons to enhance the dose deposition only within the tumor. With SSRT already in its clinical trial stage at the ESRF, most medical physics problems are already solved and the implemented solutions are briefly described, while the medical physics aspects in MRT will be discussed in more detail in this paper.