Percutaneous pulmonary valve implantation (PPVI) is used to treat pulmonary stenosis (PS) or pulmonary regurgitation (PR). We described our experience with PPVI, specifically valve-in-valve transcatheter pulmonary valve replacement using the Melody valve and novel self-expandable systems using the Pulsta valve. We reviewed data from 42 patients undergoing PPVI. Twenty-nine patients had Melody valves in mostly bioprosthetic valves, valved conduits, and homografts in the pulmonary position. Following Melody valve implantation, the peak right ventricle-to-pulmonary artery gradient decreased from 51.3 ± 11.5 to 16.7 ± 3.3 mmHg and right ventricular systolic pressure fell from 70.0 ± 16.8 to 41.3 ± 17.8 mmHg. Thirteen patients with native right ventricular outflow tract (RVOT) lesions and homograft underwent PPVI with the new self-expandable Pulsta valve—a nitinol wire stent mounted with a trileaflet porcine pericardial valve. Following Pulsta valve implantation, cardiac magnetic resonance imaging showed a decreased PR fraction and that the right ventricular end-diastolic volume index decreased from 166.1 ± 11.9 to 123.6 ± 12.4 mL/m2. There were no mortality, severe procedural morbidity, or valve-related complications. At the mean 14.2 month (4–57 months) follow-up, no patients had more than mild PR. PPVI using Melody and Pulsta valves was first shown to provide excellent early outcomes without serious adverse event in most patients with RVOT dysfunction in Korea.
Background: Despite the development of several imaging modalities for diagnosing Fontan-associated liver disease (FALD), there is no optimal protocol for the follow-up of FALD. We conducted a systematic review and meta-analysis to identify factors related to liver fibrosis using biopsy reports and to identify alternative noninvasive modalities that could better reflect liver histological changes in FALD. Methods: A systematic review and meta-analysis were conducted following the PRISMA guidelines Table S2. We searched Embase, PubMed, and Cochrane databases for studies on FALD, focusing on those assessing clinical factors associated with liver fibrosis severity through liver biopsy and noninvasive imaging techniques. Results: A total of 42 studies were identified, of which 12 conducted meta-analyses and subgroup analyses of the severity of liver fibrosis using liver biopsies. Liver biopsy results showed a weak positive correlation between Fontan duration and fibrosis severity (R = 0.36). Subgroup analyses revealed significant differences in hemodynamic parameters, such as Fontan pressure, between patients with mild and severe fibrosis. Platelet count, aspartate aminotransferase to platelet ratio index, and fibrosis-4 index were significantly associated with fibrosis severity, with severe fibrosis showing lower platelet counts and higher aspartate aminotransferase to platelet ratio index and fibrosis-4 index levels. Noninvasive imaging modalities, particularly magnetic resonance elastography and shear wave elastography, demonstrated strong correlations with biopsy-confirmed fibrosis severity. Conclusions: This study identifies key clinical factors, and noninvasive modalities accurately reflect liver fibrosis severity in patients with FALD. Clinical factors such as platelet count, aspartate aminotransferase to platelet ratio index, and fibrosis-4 index may aid in identifying patients at risk for severe fibrosis. In addition, magnetic resonance elastography and shear wave elastography are promising tools for noninvasive assessment in our study. Further research is needed to refine these diagnostic approaches and improve patient management.
19 July 2022 in Circulation: Cardiovascular Imaging
Background: Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. Methods: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. Results: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6–79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time ( P <0.001), and a similar pattern was observed in the shunt flow ( P <0.001). The bulkiness of devices also decreased in proportion to the postprocedural period ( P <0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04–1.27]; P <0.001) as the only significant factor of incomplete NE and major adverse events. Conclusions: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE.