N-CDs were prepared with a high fluorescence quantum yield of 35.08%. N-CDs have been employed to detect metronidazole in commercial metronidazole tablets. N-CDs exhibited quick response time, high selectivity and sensitivity, and low cytotoxicity.
Mushrooms have limited shelf-life and it can be prolonged if suitable conditions and treatments are effectively applied. In this study, nanocomposite material and antimicrobial agents with a combination of chitosan were used as novel packaging material for mushroom preservation. The microbiological analysis, physicochemical properties, headspace gas analysis, and polyphenol oxidase activity (PPO) during cold storage were investigated. As compared with control, coated mushrooms with chitosan (CHS), and nano-titanium dioxide CHSTiO2 thymol + tween-80 CHSTiO2/TT80 coating treatment showed significantly (p ≤ 0.05) lower respiration rate, microbial contaminations (4.27 log CFU/g), and (5.93 log CFU/g) for total yeast/mold and aerobic plate counts, respectively. The weight loss ratio was the lowest for CHSTiO2/TT80 (10.88% loss) followed by CHSTiO2 (11.76% loss). CHSTiO2/TT80 recorded a higher electrolyte leakage rate (25.84%) and acidity. While the lowest PPO activity was established for CHSTiO2 (17.09 U mg−1 Protein), while the lowest values for total soluble solid concentrations were reported for CHSTiO2/TT80 mushrooms (4.91%). These results indicated that CHSTiO2/TT80 coating treatment might delay the aging degree of white button mushrooms and be investigated as a novel packaging material for other food products in the future.
In our study, a unique ratiometric fluorescent sensor for the rapid detection of arginine (Arg) and acetaminophen (AP) was constructed by the integration of blue fluorescent N-CDs and yellowish-green fluorescent calcein. The N-CD/calcein ratiometric fluorescent sensor exhibited dual emission at 435 and 519 nm under the same excitation wavelength of 370 nm, and caused potential Förster resonance energy transfer (FRET) from N-CDs to calcein. When detecting Arg, the blue fluorescence from the N-CDs of the N-CD/calcein sensor was quenched by the interaction of N-CDs and Arg. Then, the fluorescence of our sensor was recovered with the addition of AP, possibly due to the stronger association between AP and Arg, leading to the dissociation of Arg from N-CDs. Meanwhile, we observed an obvious fluorescence change from blue to green, then back to blue, when Arg and AP were added, exhibiting the “on–off–on” pattern. Next, we determined the detection limits of the N-CD/calcein sensor to Arg and AP, which were as low as 0.08 μM and 0.02 μM, respectively. Furthermore, we discovered that the fluorescence changes of the N-CD/calcein sensor were only responsible for Arg and AP. These results suggested its high sensitivity and specificity for Arg and AP detection. In addition, we have successfully achieved its application in bovine serum samples, indicating its practicality. Lastly, the logic gate was generated by the N-CD/calcein sensor and presented its good reversibility. Overall, we have demonstrated that our N-CD/calcein sensor is a powerful sensor to detect Arg and AP and that it has potential applications in biological analysis and imaging.
Nitrogen-doped carbon dots exhibiting excitation-dependent full-color emissions (F-NCDs) were prepared via the one-step hydrothermal method with citric acid and phenylenediamine. Specifically, the emission wavelength of the F-NCDs tuned from 452 nm to 602 nm due to the introduction of new energy levels by C=O and C=N functional groups. We exploited its stability in illumination, ionic strength, and pH, as well as its specificity, sensitivity, especially in ascorbic acid (AA) detection. F-NCDs could measure the AA concentration in the linear ranges of 0~0.1 and 0.1~1 mmol/L with the detection limit (LOD, S/N = 3) as low as 2.6 nmol/L. Additionally, we successfully detected AA in bovine serum with our F-NCDs and obtained the result within 1 min. Because of full-color emission features, we believe our F-NCDs have a great potential in fluorescent sensor detection.