Rapid antigen detection (RAD) tests are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC), presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One hundred and twenty samples were selected and tested with both RT-qPCR and six commercial RAD tests that are commonly sold in Belgian pharmacies. Of these, direct whole-genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron (BA.1 and BA.1.1 sub-lineages, respectively). The sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) ranged from 70.0% to 92.9% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25, corresponding to <4.9 log10 copies/mL), only the Roche RAD test showed acceptable performances for the Delta strains (80.0%), while poor performances were observed for the other RAD tests (20.0% to 40.0%). All the tested devices had poor performances for the Omicron samples with a low viral load (0.0% to 23.1%). The poor performances observed with low viral loads, particularly for the Omicron strain, is an important limitation of RAD tests, which is not sufficiently highlighted in the instructions for use of these devices.
28 September 2021 in International Journal of Laboratory Hematology
Rapid antigen detection tests (RAD) are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC) presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One-hundred and twenty samples were selected and tested with both RT-qPCR and five commercial RAD commonly sold in Belgian pharmacies. Of these, direct whole genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron. Sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) were comparable and ranged from 70.0% to 77.1% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25), poor performances were observed for the Delta strains (20.0 to 40.0%) and, even more so, for Omicron strains (0.0 to 23.1%). Two devices failed to detect all samples (n = 13) containing Omicron strains with a low viral load. The poor performance observed with low viral loads is an important limitation of RAD, which is not sufficiently highlighted in the instruction for use of these devices.
31 January 2024 in International Journal of Laboratory Hematology
Background: Estrogen receptor (ER)‐positive (ER+) breast cancer accounts for approximately 75% of all breast cancers. Tamoxifen, a selective estrogen receptor modulator, is the standard adjuvant treatment. Although better tolerated than aromatase inhibitors, tamoxifen increases the risk of venous thromboembolism (VTE) 1.4‐fold.Aim: To assess the hemostatic imbalance induced by tamoxifen in adjuvant treatment of ER+ breast cancer.Method: Twenty‐five patients in remission from ER+ breast cancer under tamoxifen were included. One hundred and thirty one age‐ and BMI‐matched healthy controls were included to establish reference ranges of thrombin generation assay (TGA) parameters. TGA was performed in the absence and presence of exogenous activated protein C (APC) to calculate the normalized APC sensitivity ratio (nAPCsr), a marker of APC resistance.Results: All TG parameters except the endogenous thrombin potential (ETP) (−APC) were significantly impacted by tamoxifen (p < 0.001). In absence of APC, regardless of TGA parameters, at least 50% of results were outside the reference ranges except for ETP, which was above the upper reference limit in only two individuals. The most impacted parameter was the Peak Height with 52% (−APC) and 80% (+APC) of results above the upper reference range limit, respectively. The nAPCsr was significantly higher in tamoxifen users (mean ± standard deviation = 3.18 ± 0.91) compared to the control group (2.19 ± 0.92, p < 0.0001).Conclusion: This observational study showed that patients in remission from ER+ breast cancer taking tamoxifen had altered thrombin generation, as well as an acquired APC resistance. Moreover, this is the first study using the validated ETP‐based APC resistance assay in tamoxifen‐treated patients.
11 January 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Article Spike vs. nucleocapsid serum antigens for COVID-19 diagnosis and severity assessment was published on January 11, 2022 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).
15 November 2021 in International Journal of Laboratory Hematology