Milena Živković

Mr. Milena Živković

University of Kragujevac, Kragujevac, Serbia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2025 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
MŽMilena Živković
Milena Živković
AAAli H D Alshehri
Ali H D Alshehri
abdulhady Abasabdulhady Abas
abdulhady Abas
DKDragana Krstic
Dragana Krstic
FSFatimah A. Salem
Fatimah A. Salem
SBSnezana R. Brankovic
Snezana R. Brankovic

1 January 2021 in Kragujevac Journal of Science
Verified
Journal Article
Open access
PDF file
MŽMilena Živković
Milena Živković
Nenad ZlatićNenad Zlatić
Nenad Zlatić
DKDragana Krstic
Dragana Krstic
Milan StankovicMilan Stankovic
Milan Stankovic
In the present work, we determined activity concentrations of ten Medicinal herbs using gamma spectrometry. The radioactivity concentration of 226 Ra, 232 Th, 40 K and 137 Cs were 2.82, 0.63, 984.32, 0.28 Bq/kg, respectively. These doses are not hazardous to the general public's health. The mean values of radium equivalent activity (Raeq), absorbed dose rates (D), annual effective dose (De) and external hazard index (Hex) are 79.51 Bq/kg, 42.73 nGy-1 , 52.40 µSv and 0.21, respectively. Medicinal plants used to make tea do not contain a concentration of tested radionuclides that would cause negative consequences to one's health.

1 January 2022 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
MŽMilena Živković
Milena Živković
TMTatjana B. Miladinović
Tatjana B. Miladinović
AMAleksandar M. Miladinović
Aleksandar M. Miladinović
UMUna J. Molnar
Una J. Molnar
DKDragana Krstic
Dragana Krstic
This paper illustrates the potential of the FOTELP-VOX code, a modification of the general-purpose FOTELP code, combining Monte Carlo techniques to simulate particle transportation from an external source through the internal organs, resulting in a 3-D absorbed dose distribution. The study shows the comparison of results obtained by FOTELP software and the volumetric modulated arc therapy technique. This planning technique with two full arcs was applied, and the plan was created to destroy the diseased tissue in the eye tumor bed and avoid damage to surrounding healthy tissue, for one patient. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were calculated. Good agreement of the results for absorbed dose in the human eye was obtained using these two techniques.

18 April 2022 in Environments
Verified
Journal Article
Open access
PDF file
PFPaolo Ferrari
Paolo Ferrari
MGMercè Ginjaume
Mercè Ginjaume
OHOliver Hupe
Oliver Hupe
UOUna O’connor
Una O’connor
FVFilip Vanhavere
Filip Vanhavere
MŽMilena Živković
Milena Živković
EURADOS (European Radiation Dosimetry Group) Working Group 12 (WG12) SG1 activities are aimed at occupational radiation protection and individual monitoring in X-ray and nuclear medicine practices. In recent years, many studies have been carried out in these fields, especially for interventional radiology and cardiology workplaces (IC/IR). The complexity of the exposure conditions of the medical staff during interventional practices makes the radiation protection and monitoring of the exposed workers a challenging task. The scope of the present work is to review some of the main results obtained within WG12 activities about scattered field characterization and personal dosimetry that could be very useful in increasing the quality of radiation protection of the personnel, safety, and awareness of radiation risk. Two papers on Monte Carlo modelling of interventional theater and three papers on active personal dosimeters (APDs) for personnel monitoring were considered in the review. More specifically, Monte Carlo simulation was used as the main tool to characterize the levels of exposure of the medical staff, allowing to determine how beam energy and direction can have an impact on the doses received by the operators. Indeed, the simulations provided information about the exposure of the operator’s head, and the study concluded with the determination of an eye-lens protection factor when protection goggles and a ceiling shielding are used. Moreover, the review included the results of studies on active personal dosimeters, their use in IC/IR workplaces, and how they respond to calibration fields, with X-ray standard and pulsed beams. It was shown that APDs are insensitive to backscatter radiation, but some of them could not respond correctly to the very intense pulsed fields (as those next to the patient in interventional practices). The measurements during interventional procedures showed the potential capability of the employment of APDs in hospitals.

10 December 2022 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
DKDragana Krstic
Dragana Krstic
DNDragoslav Nikezic
Dragoslav Nikezic
MJMarija Z Jeremic
Marija Z Jeremic
EDEdin Dolicanin
Edin Dolicanin
TMTatjana B Miladinovic
Tatjana B Miladinovic
MŽMilena Živković
Milena Živković

20 May 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MŽMilena Živković
Milena Živković
FAFilip Andrić
Filip Andrić
MSMarina Svičević
Marina Svičević
DKDragana Krstic
Dragana Krstic
LKLazar Krstic
Lazar Krstic
MAMohamed El Amin Aichouche
Mohamed El Amin Aichouche