Paolo Ferrari

Dr. Paolo Ferrari

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2003 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
AMAntonio Marigo
Antonio Marigo
Carla MaregaCarla Marega
Carla Marega
Valerio CausinValerio Causin
Valerio Causin
PFPaolo Ferrari
Paolo Ferrari

18 November 2016 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
PFPaolo Ferrari
Paolo Ferrari
FBFrank Becker
Frank Becker
ECEleftheria Carinou
Eleftheria Carinou
VCVadim Chumak
Vadim Chumak
JFJad Farah
Jad Farah
PTPedro Teles
Pedro Teles
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator’s head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator’s head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.

7 August 2019 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
PFPaolo Ferrari
Paolo Ferrari
FBFrank Becker
Frank Becker
ZJZoran Jovanovic
Zoran Jovanovic
SKShahed Khan
Shahed Khan
EBElena Bakhanova
Elena Bakhanova
MBMarco Bertolini
Marco Bertolini
Interventional radiology and cardiology are widespread employed techniques for diagnosis and treatment of several pathologies because they avoid the majority of the side-effects associated with surgical treatments, but are known to increase the radiation exposure to patient and operators. In recent years many studies treated the exposure of the operators performing cardiological procedures. The aim of this work is to study the exposure condition of the medical staff in some selected interventional radiology procedures. The Monte Carlo simulations have been employed with anthropomorphic mathematical phantoms reproducing the irradiation scenario of the medical staff with two operators and the patient. A personal dosemeter, put on apron, was modelled for comparison with measurements performed in hospitals, done with electronic dosemeters, in a reduced number of interventional radiology practices. Within the limits associated to the use of numerical anthropomorphic models to mimic a complex interventional procedure, the personal dose equivalent, H p (10), was evaluated and normalised to the simulated Kerma-Area Product, KAP, value, indeed the effective dose has been calculated. The H p (10)/KAP value of the first operator is about 10 μ Sv/Gy.cm 2 , when ceiling shielding is not used. This value is calculated on the trunk and it varies of +/−30% moving the dosemeter to the waist or to the neck. The effective dose, normalised to the KAP value, varies between 0.03 and 0.4 μ Sv/Gy.cm 2 . Considering all the unavoidable approximation of this kind of investigations, the comparisons with hospital measurement and literature data showed a good agreement allowing to use of the present results for dosimetric characterisation of interventional radiology procedures.

26 February 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
HRHans Rabus
Hans Rabus
JGJose-Maria Gomez-Ros
Jose-Maria Gomez-Ros
CVCarmen Villagrasa
Carmen Villagrasa
JEJonathan Eakins
Jonathan Eakins
TVTomas Vrba
Tomas Vrba
PFPaolo Ferrari
Paolo Ferrari
Working Group (WG) 6 ‘Computational Dosimetry’ of the European Radiation Dosimetry Group promotes good practice in the application of computational methods for radiation dosimetry in radiation protection and the medical use of ionising radiation. Its cross-sectional activities within the association cover a large range of current topics in radiation dosimetry, including more fundamental studies of radiation effects in complex systems. In addition, WG 6 also performs scientific research and development as well as knowledge transfer activities, such as training courses. Monte Carlo techniques, including the use of anthropomorphic and other numerical phantoms based on voxelised geometrical models, play a strong part in the activities pursued in WG 6. However, other aspects and techniques, such as neutron spectra unfolding, have an important role as well. A number of intercomparison exercises have been carried out in the past to provide information on the accuracy with which computational methods are applied and whether best practice is being followed. Within the exercises that are still ongoing, the focus has changed towards assessing the uncertainty that can be achieved with these computational methods. Furthermore, the future strategy of WG 6 also includes an extension of the scope toward experimental benchmark activities and evaluation of cross-sections and algorithms, with the vision of establishing a gold standard for Monte Carlo methods used in medical and radiobiological applications.

4 January 2019 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
MGMercè Ginjaume
Mercè Ginjaume
ECEleftheria Carinou
Eleftheria Carinou
MBMarcin Brodecki
Marcin Brodecki
ICIsabelle Clairand
Isabelle Clairand
JDJoanna Karolina Domienik-Andrzejewska
Joanna Karolina Domienik-Andrzejewska
FVFilip Vanhavere
Filip Vanhavere
In fluoroscopy guided interventional procedures, workers use protective garments and often two personal dosemeters, the readings of which are used for the estimation of the effective dose; whereas the dosemeter above the protection can be used for the estimation of the equivalent dose of the lens of the eye. When a protective apron is worn the scattered field that reaches the dosemeter is different from the case where no protection is used; this study analyses the changes in the response of seven passive and eight active personal dosemeters (APDs) when they are placed above a lead or lead equivalent garment for S-Cs and x-ray diagnostic qualities. Monte Carlo simulations are used to support the experimental results. It is found that for passive dosemeters, the influence on the dosemeter’s response to the lead or lead equivalent was within the range 15%–38% for the x-ray qualities. This effect is smaller, of the order of 10%, when lead-free garments are used, and much smaller, within 1%–10%, for most of the APDs used in the study. From these results it is concluded that when comparing passive and active dosemeter measurements worn above the protection, a difference of 20%–40% is expected. The effect is small when deriving the effective dose from double dosimetry algorithms, but it can be of major importance when eye lens monitoring is based on the use of the dosemeter worn above the protection.

10 May 2010 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PFPaolo Ferrari
Paolo Ferrari
GVG. Venturi
G. Venturi
GGG. Gualdrini
G. Gualdrini
PRPier Luca Rossi
Pier Luca Rossi
MMM. Mariselli
M. Mariselli
RZR. Zannoli
R. Zannoli
Interventional radiology, among guided X-rays procedures, is a methodology characterised by high level of doses, both for the patient and for the medical staff. The aim of the present study is to estimate the dose associated with coronary angiography procedures by means of numerical models (simplified and anthropomorphic) and MCNPX Monte Carlo code. Numerical estimates were supported by measurement performed with a dose area product meter that is commonly employed in such kind of studies. In the present work the main considerations and the preliminary results are presented.