Zhi Xu

Prof. Zhi Xu

China Southern Power Grid (China), Guangzhou, Guangdong, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZXZhi Xu
Zhi Xu
JTJianxiong Tang
Jianxiong Tang
YJYupeng Jiang
Yupeng Jiang
YWyixuan wang
yixuan wang
HMHongsheng Ma
Hongsheng Ma
CZChengyong Zhao
Chengyong Zhao
With the rapid development of cities and the increasing complexity of distribution network systems, the cableization of transmission lines and the diversification of power users have brought new challenges to the supply reliability of distribution networks. Short-time outages caused by power outages and maintenance are one of the factors that affect the reliability of the power supply in the distribution network. The non-stop load transfer through a phase-shifting transformer (PST) operation can effectively improve the reliability of power supply to complex distribution systems. Considering the operation mode and structure form and fault type of the urban distribution network in China, comparing and analyzing the applicable scenarios of different neutral grounding methods, and based on the structure and zero sequence path characteristics of PST, an improved PST-based phase shifting and grounding transformer loop closing device with low power consumption is proposed. The fault characteristics of the PST-based loop closing device under the small current grounding system are also analyzed by the sequence component method, and, finally, the effectiveness of the phase-shifting and grounding transformer device is verified by simulation under PSCAD/EMTDC for fault routing and protection configuration of the urban distribution network in China.

11 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Jingang WangJingang Wang
Jingang Wang
CSChen Shen
Chen Shen
Pengcheng ZhaoPengcheng Zhao
Pengcheng Zhao
SOShucheng Ou
Shucheng Ou
ZXZhi Xu
Zhi Xu
ZSZhiming Song
Zhiming Song
This paper proposes a coil design method for the magnetically coupled resonant wireless power transfer (MCR-WPT) system. Based on the Biot–Savart law, the magnetic flux density at the observation point was derived, and the magnetic flux of the observation plane generated by the exciting coil was deduced to build the calculation model of power transfer efficiency (PTE) and power delivered to the load (PDL). The PTE and PDL curves via coil parameters could be fitted in minutes using numerical calculation. The coil was designed according to transmission objectives and dimension constraints. In addition, the calculated PTE and PDL were compared with those from finite element analysis to verify the credibility of the method. Finally, the actual curves of PTE and PDL were achieved, which showed a strong positive correlation with the corresponding curves from the calculation model. The relative average deviations of PDL curves were less than 6.11%. Meanwhile, coils designed with the numerical calculation could realize 309.80 W and 88.51%, which achieved the objectives under the constraints. The results demonstrate that the proposed method can realize a rapid and accurate coil design under constraints. It can also be applied to other coil structures or circuit topologies with strong universality.

3 November 2026 in Processes
Verified
Journal Article
Open access
PDF file
ZXZhi Xu
Zhi Xu
RQRisheng Qin
Risheng Qin
MRMin Ren
Min Ren
HJHe Jiang
He Jiang
XXXinze Xi
Xinze Xi
YJYang Jun
Yang Jun
Rural integrated energy systems (RIESs) suffer from volatile renewable generation, surging agricultural peak loads, and unevenly distributed forecast errors, which severely undermine scheduling robustness and economic efficiency. Conventional fixed-scenario robust scheduling cannot dynamically adapt to error variations, leading to either excessive conservatism or insufficient operational safety. This paper proposes a forecast-error-driven multi-time-scale hybrid robust-scenario scheduling framework with a three-layer closed-loop architecture: day-ahead multi-scenario robust baseline scheduling, intraday error-driven rolling correction, and real-time dynamic-simulation calibration. Case studies on a practical Yunnan rural system verify that within ±25% forecast error, the proposed method reduces operating costs by 12.8%, increases the renewable energy accommodation rate by 22.6%, lowers the dynamic constraint-violation rate below 0.05%, and maintains the average solution time within 9 s, achieving a superior balance of resilience and economy for complex rural operations.

21 September 2026 in Processes
Verified
Journal Article
Open access
PDF file
JYJunwen Yang
Junwen Yang
ZXZhi Xu
Zhi Xu
MRMin Ren
Min Ren
HJHe Jiang
He Jiang
XXXinze Xi
Xinze Xi
JSJie Shu
Jie Shu
Against the backdrop of China’s “carbon peaking and carbon neutrality” goals, the abundant renewable resources in rural areas offer natural advantages for developing distributed integrated energy systems. However, the economic feasibility of advanced technologies such as carbon capture and hydrogen energy storage in rural applications requires further evaluation. This paper proposes a rural integrated energy system (RIES) architecture that integrates hydrogen energy storage and carbon cycling, encompassing six types of energy and material carriers—electricity, heat, gas, hydrogen, carbon, and biomass—and establishes a mixed-integer linear programming (MILP) model aimed at minimizing the total annual cost. Taking a typical rural village in northern China as a case study, capacity configuration optimization is conducted for five technical scenarios, and the impacts of the local generation ratio target, photovoltaic (PV) curtailment penalty coefficient, hydrogen storage efficiency, hydrogen energy subsidies, and equipment investment costs are analyzed.The results indicate that the scenario equipped with both carbon cycling and hydrogen storage achieves the lowest total annual cost, approximately 6.8% lower than that of the conventional RIES, with the local generation ratio increasing by about 4.0 percentage points and the PV curtailment rate dropping to 2.2%. Among these, carbon cycling is the primary source of cost reduction, while hydrogen storage further improves local power supply contribution and PV utilization. Sensitivity analysis indicates that increasing the local generation ratio can reduce electricity purchases from the grid, but at the cost of higher equipment investment; the PV curtailment penalty mainly affects PV capacity configuration and the level of PV curtailment, while hydrogen energy efficiency, subsidies, and equipment cost reductions influence the economic attractiveness of hydrogen energy equipment. The findings can provide a reference for the synergistic deployment of carbon cycling and hydrogen storage in RIES.