Pan Xia

Pan Xia


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
YWYuqi Wang
Yuqi Wang
LZLijun Zhang
Lijun Zhang
PXPan Xia
Pan Xia
PWPeng Wang
Peng Wang
XCXianxiang Chen
Xianxiang Chen
MDMingyan Du
Mingyan Du
Emotion recognition is receiving significant attention in research on health care and Human-Computer Interaction (HCI). Due to the high correlation with emotion and the capability to affect deceptive external expressions such as voices and faces, Electroencephalogram (EEG) based emotion recognition methods have been globally accepted and widely applied. Recently, great improvements have been made in the development of machine learning for EEG-based emotion detection. However, there are still some major disadvantages in previous studies. Firstly, traditional machine learning methods require extracting features manually which is time-consuming and rely heavily on human experts. Secondly, to improve the model accuracies, many researchers used user-dependent models that lack generalization and universality. Moreover, there is still room for improvement in the recognition accuracies in most studies. Therefore, to overcome these shortcomings, an EEG-based novel deep neural network is proposed for emotion classification in this article. The proposed 2D CNN uses two convolutional kernels of different sizes to extract emotion-related features along both the time direction and the spatial direction. To verify the feasibility of the proposed model, the pubic emotion dataset DEAP is used in experiments. The results show accuracies of up to 99.99% and 99.98 for arousal and valence binary classification, respectively, which are encouraging for research and applications in the emotion recognition field.

30 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Lirui XuLirui Xu
Lirui Xu
PWPeng Wang
Peng Wang
PXPan Xia
Pan Xia
PWPang Wu
Pang Wu
XCXianxiang Chen
Xianxiang Chen
ZFZhen Fang
Zhen Fang
Pulse wave velocity (PWV) measured at a specific artery location is called local PWV, which provides the elastic characteristics of arteries and indicates the degree of arterial stiffness. However, the large and cumbersome ultrasound probes require an appropriate sensor position and pressure maintenance, introducing usability constraints. In this paper, we developed a light (0.5 g) and thin (400 μm) flexible ultrasound array by encapsulating 1–3 composite piezoelectric transducers with a silicone elastomer. It can capture the distension waveforms of four arterial positions with a spacing of 10 mm and calculate the local PWV by multi-point fitting. This is illustrated by in vivo experiments, where the local PWV value of five normal subjects ranged from 3.07 to 4.82 m/s, in agreement with earlier studies. The beat-to-beat coefficient of variation (CV) is 12.0% ± 3.5%, showing high reliability. High reproducibility is shown by the results of two groups of independent measurements of three subjects (the error between the mean values is less than 0.3 m/s). These properties of the developed flexible ultrasound array enable the bandage-like application of local PWV monitoring to skin surfaces.

11 May 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
YZyusi Zhu
yusi Zhu
PXPan Xia
Pan Xia
JLJihang Liu
Jihang Liu
ZFZhen Fang
Zhen Fang
LDLi Dong Du
Li Dong Du
ZZZhan Zhao
Zhan Zhao
Respiration monitoring is vital for human health assessment. Humidity sensing is a promising way to establish a relationship between human respiration and electrical signal. This paper presents a polyimide-based film bulk acoustic resonator (PI-FBAR) humidity sensor operating in resonant frequency and reflection coefficient S11 dual-parameter with high sensitivity and stability, and it is applied in real-time human respiration monitoring for the first time. Both these two parameters can be used to sense different breathing conditions, such as normal breathing and deep breathing, and breathing with different rates such as normal breathing, slow breathing, apnea, and fast breathing. Experimental results also indicate that the proposed humidity sensor has potential applications in predicting the fitness of individual and in the medical field for detecting body fluids loss and daily water intake warning. The respiratory rates measured by our proposed PI-FBAR humidity sensor operating in frequency mode and S11 mode have Pearson correlation of up to 0.975 and 0.982 with that measured by the clinical monitor, respectively. Bland–Altman method analysis results further revealed that both S11 and frequency response are in good agreement with clinical monitor. The proposed sensor combines the advantages of non-invasiveness, high sensitivity and high stability, and it has great potential in human health monitoring.

26 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PXPan Xia
Pan Xia
ZHZhang Hao
Zhang Hao
YYYicheng Yao
Yicheng Yao
Lirui XuLirui Xu
Lirui Xu
ZBZhongrui Bai
Zhongrui Bai
ZFZhen Fang
Zhen Fang
Multi-label electrocardiogram (ECG) classification is of great significance for the diagnosis of cardiovascular diseases, and it is also a challenging task because of the various of pathological patterns across different cardiac abnormalities. This paper analyzes the complex spatial-temporal variations information contained in the 12-lead ECG from a new perspective, and proposes an advanced deep neural network framework to accurately identify various multi-label ECG abnormalities. Firstly, the 12-lead ECG was modeled as 3-dimensional (3-D) spatial-temporal variations involving the intra-period, inter-period temporal dimensions, and cross-lead spatial dimension. Then, a 3-D spatial-temporal learning network (3D-STLNet) was carefully designed to extract the complex pathological features from the 3-D spatial-temporal variations. Secondly, the multi-head attention (MHA) mechanism was introduced into the proposed network to extract global temporal dependencies in ECG segments, which further improved the performance of the proposed network. By integrating a residual backbone network, a 3D-STLNet, and the MHA module, our proposed network allows end-to-end learning and prediction in a unified framework. The influence of several classic threshold selection strategies on the performance of multi-label ECG classification algorithm was also analyzed, which provides a reference for subsequent research on optimal threshold selection for multi-label ECG classification. Finally, our proposed network was evaluated on multiple large multi-label ECG public datasets, and the performance of our network outperforms that of current state-of-the-art networks, which demonstrates that our network has great competitiveness in identifying a wider range of multi-label ECG abnormalities.

22 August 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YYYicheng Yao
Yicheng Yao
ZHZhang Hao
Zhang Hao
ZBZhongrui Bai
Zhongrui Bai
PXPan Xia
Pan Xia
CLChangyu Liu
Changyu Liu
ZFZhen Fang
Zhen Fang
It is essential to find and treat the elderly in time after they fall. Millimeter wave radar sensor not only solves the problem of invasion of privacy caused by the camera but also avoids letting patients wear wearable devices, which has received more and more attention in the field of fall detection and motion recognition. Due to the different modulation of radar signals by different users and environments, the performance of the fall detection model is inevitably reduced. In this paper, we propose a highly generalized radar-based fall detection framework to improve the generalization of the fall detection system in the new domain. We use a feature extractor with a ResNet structure constructed from three-dimensional convolution to extract features of the signal, and a multilayer perceptron as a classifier for fall detection. We measure the cross-domain cross entropy of the features by setting subclassifiers for each domain to measure the cross-domain invariance of the features, enabling the feature extractor to extract domain-invariant features. We propose a specific data augmentation technology for radar time series signals, which is combined with the proposed model to achieve more generalized fall detection. We have conducted sufficient experiments to explore the relationship between the number of users and domains and the model’s generalization. The proposed method achieves an F1 score of 0.9747 on the proposed dataset containing 10 scenarios, 21 subjects, 52 non-falling actions and 12 falling actions, and an F1 score of 0.9949 on the public dataset, which shows superior effectiveness.

1 April 2025 in Tsinghua Science and Technology
Verified
Journal Article
Closed access
PWPang Wu
Pang Wu
ZBZhongrui Bai
Zhongrui Bai
PXPan Xia
Pan Xia
Lirui XuLirui Xu
Lirui Xu
PWPeng Wang
Peng Wang
ZFZhen Fang
Zhen Fang
Accurate and portable Blood Pressure (BP) monitoring is vital for managing cardiovascular diseases. However, existing wearable continuous BP monitoring technologies are often inaccurate and rely on external calibration, limiting their practical application in continuous BP monitoring. To address this challenge, we have developed a Wearable continuous non-invasive BP Monitor (WeBPM) equipped with a finger cuff sensor, capable of monitoring BP continuously and accurately within medical-grade precision. WeBPM integrates advanced finger oscillographic BP measurement technology to provide reliable self-calibration functionality. Moreover, Pulsatile Cycle Volume Adjustment Method (PCVAM) we proposed for the closed-loop phase can continuously track changes in vasomotor tone under a controlled frequency based on pulsatile cycles, thereby enabling continuous BP measurement. In comparative experiments with the Nexfin monitor, WeBPM demonstrates excellent performance in induced dynamic BP experiments, with measurement errors of (-1.4 ± 6.24) mmHg for Systolic BP (SBP) and (-0.82 ± 4.83) mmHg for Diastolic BP (DBP). Additionally, compared to clinical invasive reference measurements, WeBPM's SBP and DBP measurement errors are (-1.74 ± 4.9) mmHg and (0.37 ± 3.28) mmHg, respectively, further proving its outstanding performance. These results highlight WeBPM's potential in personalized health management and remote monitoring, offering a new solution for continuous non-invasive BP monitoring.