Pulse wave velocity (PWV) measured at a specific artery location is called local PWV, which provides the elastic characteristics of arteries and indicates the degree of arterial stiffness. However, the large and cumbersome ultrasound probes require an appropriate sensor position and pressure maintenance, introducing usability constraints. In this paper, we developed a light (0.5 g) and thin (400 m) flexible ultrasound array by encapsulating 1–3 composite piezoelectric transducers with a silicone elastomer. It can capture the distension waveforms of four arterial positions with a spacing of 10 mm and calculate the local PWV by multi-point fitting. This is illustrated by in vivo experiments, where the local PWV value of five normal subjects ranged from 3.07 to 4.82 m/s, in agreement with earlier studies. The beat-to-beat coefficient of variation (CV) is 12.0% ± 3.5%, showing high reliability. High reproducibility is shown by the results of two groups of independent measurements of three subjects (the error between the mean values is less than 0.3 m/s). These properties of the developed flexible ultrasound array enable the bandage-like application of local PWV monitoring to skin surfaces.
Accurate and portable Blood Pressure (BP) monitoring is vital for managing cardiovascular diseases. However, existing wearable continuous BP monitoring technologies are often inaccurate and rely on external calibration, limiting their practical application in continuous BP monitoring. To address this challenge, we have developed a Wearable continuous non-invasive BP Monitor (WeBPM) equipped with a finger cuff sensor, capable of monitoring BP continuously and accurately within medical-grade precision. WeBPM integrates advanced finger oscillographic BP measurement technology to provide reliable self-calibration functionality. Moreover, Pulsatile Cycle Volume Adjustment Method (PCVAM) we proposed for the closed-loop phase can continuously track changes in vasomotor tone under a controlled frequency based on pulsatile cycles, thereby enabling continuous BP measurement. In comparative experiments with the Nexfin monitor, WeBPM demonstrates excellent performance in induced dynamic BP experiments, with measurement errors of (-1.4 ± 6.24) mmHg for Systolic BP (SBP) and (-0.82 ± 4.83) mmHg for Diastolic BP (DBP). Additionally, compared to clinical invasive reference measurements, WeBPM's SBP and DBP measurement errors are (-1.74 ± 4.9) mmHg and (0.37 ± 3.28) mmHg, respectively, further proving its outstanding performance. These results highlight WeBPM's potential in personalized health management and remote monitoring, offering a new solution for continuous non-invasive BP monitoring.
Heartbeat inter-beat interval (IBI) extraction is a crucial technology for unobtrusive vital sign monitoring, yet its precision and robustness remain challenging. A promising approach is fusing heartbeat signals from different types of unobtrusive sensors. This paper introduces HSF-IBI, a novel and universal framework for unobtrusive IBI extraction using heterogeneous sensor fusion. Specifically, harmonic summation (HarSum) is employed for calculating the average heart rate, which in turn guides the selection of the optimal band selection (OBS), the basic sequential algorithmic scheme (BSAS)-based template group extraction, and the template matching (TM) procedure. The optimal IBIs are determined by evaluating the signal quality index (SQI) for each heartbeat. The algorithm is morphology-independent and can be adapted to different sensors. The proposed algorithm framework is evaluated on a self-collected dataset including 19 healthy participants and an open-source dataset including 34 healthy participants, both containing heterogeneous sensors. The experimental results demonstrate that (1) the proposed framework successfully integrates data from heterogeneous sensors, leading to detection rate enhancements of 6.25 % and 5.21 % on two datasets, and (2) the proposed framework achieves superior accuracy over existing IBI extraction methods, with mean absolute errors (MAEs) of 5.25 ms and 4.56 ms on two datasets.
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.