Qiong Li

Dr. Qiong Li


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Energy Reports
Verified
Journal Article
Open access
QLQiong Li
Qiong Li
YZYang Zou
Yang Zou
GLGuo Hua Long
Guo Hua Long
WWWenbao Wu
Wenbao Wu

26 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
WWWenbin Wang
Wenbin Wang
HWHuayun Wang
Huayun Wang
QLQiong Li
Qiong Li
JXJun Xu
Jun Xu
TMTianqi Meng
Tianqi Meng
ZZZhen Zhang
Zhen Zhang
This paper proposes a detailed analysis of the incomplete coupling effect in omnidirectional wireless power transfer systems and a compensation method aiming to improve the transmission performance. Recently, omnidirectional wireless charging technologies have been gradually explored and studied. These charging technologies can transmit power to arbitrary directions in three-dimensional space. However, there are still specific regions where the transmitted power capability dramatically drops to an extremely low level due to the incomplete coupling effect. Accordingly, this paper provides a theoretical analysis and compensation of such an effect. The compensation effectiveness is validated by both a simulation and a 7 W experimental prototype. After the compensation, the transmitted power can be improved by 61% to drive the load in a full range of the space.

17 April 2023 in Processes
Verified
Journal Article
Open access
PDF file
YCYaqi Chen
Yaqi Chen
QLQiong Li
Qiong Li
YZYang Zou
Yang Zou
GLGuohua Long
Guohua Long
NYNianping Yan
Nianping Yan
RFRuixiang Fan
Ruixiang Fan
The traditional circuit breaker fault diagnosis method suffers from insufficient feature information extraction and is easily affected by abnormal signal acquisition. To address this, this paper introduces the phase space reconstruction algorithm to reconstruct the current signal for fault diagnosis based on phase trajectory features. The proposed method uses a first-order forward differencing method and mutual information method to process abnormal data and select the parameters of the reconstruction, then extract overall and local inflection point features to construct a fault feature set. The support vector machine algorithm-based model is trained and tested using actual samples, and the results show that the proposed method can adaptively sample anomalous signals, exhibit strong robustness, and significantly improve the accuracy of fault classification.

30 November 2022 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
ZTZhiyi Tu
Zhiyi Tu
LCLiangliang Chen
Liangliang Chen
QLQiong Li
Qiong Li
XJXiaoguang Jin
Xiaoguang Jin
JWJiaju Wu
Jiaju Wu

1 November 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
HWHuayun Wang
Huayun Wang
QLQiong Li
Qiong Li
HHHong Huang
Hong Huang
HQHaoyue Qu
Haoyue Qu
WWWenbing Wang
Wenbing Wang
TMTianqi Meng
Tianqi Meng
The development of smart grid technology has improved the way in which grid companies interact with power users, but there are data breaches when data falls into the hands of malicious attackers. This paper implements a multi-blockchain system based on sovereign blockchain technology for the main body of the power trading market, and designs the data transmission mechanism and system architecture. Through the power data classification index, the effective mining and utilization of intelligent power data is realized. Incorporating national sovereignty constraints into smart contracts ensures that smart grids provide a system of trusted, nationally compliant systems for power users’ electricity transactions. Finally, the advantages of the power data management scheme proposed in this paper are analysed by comparing with the traditional power data management methods.

10 January 2023 in Frontiers in Energy Research
Verified
Journal Article
Open access
YWYihui Wu
Yihui Wu
QLQiong Li
Qiong Li
GLGuohua Long
Guohua Long
LCLiangliang Chen
Liangliang Chen
MCMuliang Cai
Muliang Cai
WWWenbao Wu
Wenbao Wu
The traditional method of detecting fault current based on threshold judgment method is limited by the current size and is easily disturbed by noise, and it is difficult to adapt to the arc ground fault detection of the distribution network. Aiming at this problem, this paper proposes a single-phase arc-optic ground fault identification method based on waveform subsequence splitting fault segmentation, combined with three-phase voltage-zero sequence voltage waveform feature extraction clustering. First of all, the waveform fault segment is segmented and located, secondly, the characteristic indexes of the time domain and frequency domain of the combined three-phase voltage-zero sequence voltage waveform are established, and the multidimensional feature distribution is reduced by the principal component analysis method, and finally, the characteristic distribution after the dimensionality reduction is identified by the K-means clustering algorithm based on the waveform subsequence. Experimental results show that the arc light grounding fault identification method proposed in this paper achieves 97.12% accurate identification of the test sample.