Liangliang Chen

Dr. Liangliang Chen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2019 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
LCLiangliang Chen
Liangliang Chen
CZChangsheng Zhu
Changsheng Zhu
ZZZhixian Zhong
Zhixian Zhong
CWChangkun Wang
Changkun Wang
ZLZhinong Li
Zhinong Li
To achieve high‐precision position control for the active magnetic bearing high‐speed flywheel rotor system (AMB‐HFRS), a novel control strategy based on inverse system method and extended two‐degree‐of‐freedom (2‐DOF) proportional–integral–derivative (PID) controller is proposed in this study. First, the inverse system method is employed to decouple the AMB flywheel rotor system with strong non‐linear and coupling, into four independent subsystems. Subsequently, extended 2‐DOF PID controllers are used to regulate the decoupled subsystems, to obtain good performances of disturbance rejection and tracking simultaneously. In the extended 2‐DOF PID controller, a differential signal is produced by a velocity observer to improve the ability of against noise. Finally, the characteristics of stability, tracking, disturbance rejection and robustness of the control strategy proposed are analysed in theory, and its ability and effectiveness to control the radial position of the AMB‐HFRS are further studied by simulations and experiments. It is shown that the control strategy proposed can keep the AMB‐HFRS suspending stably from static state to the speed of 24,000 rpm, has the advantages of good tracking, high disturbance rejection, strong robustness and good ability of against noise.

29 January 2019 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
LCLiangliang Chen
Liangliang Chen
CZChangsheng Zhu
Changsheng Zhu
ZZZhixian Zhong
Zhixian Zhong
MSMin Sun
Min Sun
WZWenlong Zhao
Wenlong Zhao
To eliminate the influence of gyroscopic effect on system stability and to improve the control performances for the active magnetic bearing (AMB) high‐speed flywheel rotor system, a novel control strategy based on the modal separation and inverse system method is proposed. The translational motions and rotational motions of the AMB flywheel rotor system are firstly decoupled by the modal separation, then the rotational motions are decoupled by the inverse system method, so that the AMB flywheel rotor system, which is a multivariable and strong coupled system, is decoupled into four subsystems. Finally, the subsystems are regulated by four two‐degrees‐of‐freedom (2‐DOF) internal model controllers, respectively. Furthermore, the stability, tracking and robustness of the novel control strategy are analysed theoretically, and its effectiveness on vibration control of the AMB high‐speed flywheel rotor system is further investigated by simulations and experiments. The results show that the novel control strategy can achieve stable suspension and effectively suppress the vibration of the AMB high‐speed flywheel rotor system from static state to 24,000 rpm, with the advantages of high stability, strong robustness, and good performances of tracking and disturbance rejection simultaneously.

21 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
DQDandan Qin
Dandan Qin
CWChao Wang
Chao Wang
YLYuliang Liu
Yuliang Liu
MLMeimin Li
Meimin Li
DHDengshan Hou
Dengshan Hou
LCLiangliang Chen
Liangliang Chen
This paper proposes a consensus–coordinated control strategy to improve the stability and reliability of interconnected direct current (DC) microgrid cluster systems based on isolated bidirectional DC–DC converters. Compared with the traditional communication-based control strategy, the proposed method does not require an additional communication system. The proposed method is only based on local measurement information, making the whole cluster form an organic unit. No matter where the power disturbance occurs in the continuous-flow microgrid, all the balance units in the system can be linked to provide emergency power support for the disturbed microgrid, improve the dynamic characteristics of the DC voltage of the disturbed microgrid, and reduce the steady-state deviation of the DC voltage of the disturbed grid. The disturbance power is reasonably borne by the balance unit of the whole system according to its equivalent power distribution coefficient ratio. Finally, the effectiveness of the proposed control strategy is verified through the PSCAD/EMTDC simulation.

30 November 2022 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
ZTZhiyi Tu
Zhiyi Tu
LCLiangliang Chen
Liangliang Chen
QLQiong Li
Qiong Li
XJXiaoguang Jin
Xiaoguang Jin
JWJiaju Wu
Jiaju Wu

11 March 2024
Verified
Book Chapter
Closed access
PDF file
WHWeijian Huang
Weijian Huang
LCLiangliang Chen
Liangliang Chen
MLMeimin Li
Meimin Li
YLYing Long
Ying Long
YPYuanxiu Peng
Yuanxiu Peng
XJXiaoguang Jin
Xiaoguang Jin