Stephen Grigg

Dr. Stephen Grigg

The Welding Institute, Cambridge, Cambridgeshire, UK
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HYHan Yang
Han Yang
Bin WangBin Wang
Bin Wang
SGStephen Grigg
Stephen Grigg
LZLing Zhu
Ling Zhu
DLDandan Liu
Dandan Liu
RMRyan Marks
Ryan Marks
One of the most significant benefits of Acoustic Emission (AE) testing over other Non-Destructive Evaluation (NDE) techniques lies in its damage location capability over a wide area. The delta-T mapping technique developed by researchers has been shown to enable AE source location to a high level of accuracy in complex structures. However, the time-consuming and laborious data training process of the delta-T mapping technique has prevented this technique from large-scale application on large complex structures. In order to solve this problem, a Finite Element (FE) method was applied to model training data for localization of experimental AE events on a complex plate. Firstly, the FE model was validated through demonstrating consistency between simulated data and the experimental data in the study of Hsu-Nielsen (H-N) sources on a simple plate. Then, the FE model with the same parameters was applied to a planar location problem on a complex plate. It has been demonstrated that FE generated delta-T mapping data can achieve a reasonable degree of source location accuracy with an average error of 3.88 mm whilst decreasing the time and effort required for manually collecting and processing the training data.

11 January 2021 in Structural Control and Health Monitoring
Verified
Journal Article
Open access
PDF file
SGStephen Grigg
Stephen Grigg
RPRhys Pullin
Rhys Pullin
MPMatthew Pearson
Matthew Pearson
DJDavid Jenman
David Jenman
RCRobert Cooper
Robert Cooper
CFCarol Ann Featherston
Carol Ann Featherston
Acoustic emission (AE) is the spontaneous release of energy caused by the growth of damage, the monitoring of which gives an indication of the presence of damage within a structure. The current standard for AE localisation is difficult to apply in a low‐power system as sensors must either be wired together or Node's time synchronised, which is power intensive. This paper proposes the use of a method of bonding three piezoelectric sensors in a small triangular array, which has previously been shown by Aljets et al. to be capable of locating sources in simple structures. In this prior work the wave's A0 mode was used to predict the angle of arrival and the distance the wave has travelled through single sensor modal analysis. This paper presents the development of hardware to apply this technique and testing that showed artificial sources could be located in simple plates to a good level of accuracy. The addition of complexity to structures significantly reduced accuracy. This prompted hardware modifications to use the S0 mode for angle prediction. Testing showed that this significantly improved performance in a complex composite structure. The power consumption of the device is very low, consuming 0.33 mW in sleep mode, 17.44 mW whilst waiting for an event and 38 mW to record, process and transmit an event. This level of consumption has the potential to be self‐powered via energy harvesting.

25 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FAFaisel Almudaihesh
Faisel Almudaihesh
SGStephen Grigg
Stephen Grigg
KHKaren Holford
Karen Holford
Rhys PullinRhys Pullin
Rhys Pullin
Mark EatonMark Eaton
Mark Eaton
Carbon Fibre-Reinforced Polymers (CFRPs) in aerospace applications are expected to operate in moist environments where carbon fibres have high resistance to water absorption; however, polymers do not. To develop a truly optimised structure, it is important to understand this degradation process. This study aims to expand the understanding of the role of water absorption on fibrous/polymeric structures, particularly in a matrix-dominant property, namely interlaminar strength. This work used Acoustic Emission (AE), which could be integrated into any Structural Health Monitoring System for aerospace applications, optical strain measurements, and microscopy to provide an assessment of the gradual change in failure mechanisms due to the degradation of a polymer’s structure with increasing water absorption. CFRP specimens were immersed in purified water and kept at a constant temperature of 90 °C for 3, 9, 24 and 43 days. The resulting interlaminar strength was investigated through short-beam strength (SBS) testing. The SBS values decreased as immersion times were increased; the decrease was significant at longer immersion times (up to 24.47%). Failures evolved with increased immersion times, leading to a greater number of delaminations and more intralaminar cracking. Failure modes, such as crushing and multiple delaminations, were observed at longer immersion times, particularly after 24 and 43 days, where a pure interlaminar shear failure did not occur. The observed transition in failure mechanism showed that failure of aged specimens was triggered by a crushing of the upper surface plies leading to progressive delamination at multiple ply interfaces in the upper half of the specimen. The crushing occurred at a load below that required to initiate a pure shear failure and hence represents an under prediction of the true SBS of the sample. This is a common test used to assess environmental degradation of composites and these results show that conservative knockdown factors may be used in design. AE was able to distinguish different material behaviours prior to final fracture for unaged and aged specimens suggesting that it can be integrated into an aerospace asset management system. AE results were validated using optical measurements and microscopy.

29 January 2022 in Inventions
Verified
Journal Article
Open access
PDF file
Romana Ewa ŚliwaRomana Ewa Śliwa
Romana Ewa Śliwa
Paweł DymoraPaweł Dymora
Paweł Dymora
Miroslaw MazurekMiroslaw Mazurek
Miroslaw Mazurek
BKBartosz Kowal
Bartosz Kowal
Michał JurekMichał Jurek
Michał Jurek
RURunar Unnthorsson
Runar Unnthorsson
Present-day technologies used in SHM (Structural Health Monitoring) systems in many implementations are based on wireless sensor networks (WSN). In the context of the continuous development of these systems, the costs of the elements that form the monitoring system are decreasing. In this situation, the challenge is to select the optimal number of sensors and the network architecture, depending on the wireless system’s other parameters and requirements. It is a challenging task for WSN to provide scalability to cover a large area, fault tolerance, transmission reliability, and energy efficiency when no events are detected. In this article, fundamental issues concerning wireless communication in structural health monitoring systems (SHM) in the context of non-destructive testing sensors (NDT) were presented. Wireless technology developments in several crucial areas were also presented, and these include engineering facilities such as aviation and wind turbine systems as well as bridges and associated engineering facilities.

10 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DLDandan Liu
Dandan Liu
Bin WangBin Wang
Bin Wang
HYHan Yang
Han Yang
SGStephen Grigg
Stephen Grigg
Acoustic emission (AE) technology is a non-destructive testing (NDT) technique that is able to monitor the process of hydrogen-induced cracking (HIC). AE uses piezoelectric sensors to convert the elastic waves generated from the growth of HIC into electric signals. Most piezoelectric sensors have resonance and thus are effective for a certain frequency range, and they will fundamentally affect the monitoring results. In this study, two commonly used AE sensors (Nano30 and VS150-RIC) were used for monitoring HIC processes using the electrochemical hydrogen-charging method under laboratory conditions. Obtained signals were analyzed and compared on three aspects, i.e., in signal acquisition, signal discrimination, and source location to demonstrate the influences of the two types of AE sensors. A basic reference for the selection of sensors for HIC monitoring is provided according to different test purposes and monitoring environments. Results show that signal characteristics from different mechanisms can be identified more clearly by Nano30, which is conducive to signal classification. VS150-RIC can identify HIC signals better and provide source locations more accurately. It can also acquire low-energy signals better, which is more suitable for monitoring over a long distance.

4 February 2021 in Engineering Research Express
Verified
Journal Article
Open access
PDF file
SGStephen Grigg
Stephen Grigg
FAFaisel Almudaihesh
Faisel Almudaihesh
MRM Roberts
M Roberts
RPR Pullin
R Pullin
The use of Acoustic Emission (AE) to detect impacts is of interest within industries where vital components are prone to impact damage, in particular where Carbon Fibre Reinforced Polymers (CFRP) are used, as damage can often go un-noticed within them. For AE monitoring of impacts piezoelectric sensors are used to detect the ultrasonic wave produced by an impact. Classification is also possible of these waves enabling a distinction between damaging and non-damaging impacts. These sensors do however have resonance, so do not give an accurate picture of how the waves propagate, better knowledge would enable better selection of sensors. Laser Doppler Vibrometry is a non-contact and non-resonant method of analysing the surface displacement on a structure. In this study, a vibrometer was used to monitor CFRP plates during impact to assess its applicability for distinguishing between damaging and non-damaging impacts, compared with a surface mounted AE sensor. The vibrometer was able to detect both low frequency flexural modes due to the impact process and the higher frequency extensional modes, initiated by damage. When compared to the AE sensor the vibrometer was comparable in its results, and unlike the sensor, not susceptible to resonance or decoupling. For the tested material the vibrometer identified frequencies greater than 20 kHz to be associated with damaging impacts.