In this paper, the reliability of transients due to pump trip as a powerful tool for the pre-localization of anomalies in real pipe systems is tested. The examined pipe system is part of the one supplying the city of Milan, Italy and is managed by Metropolitana Milanese SpA (MM). The characteristics of such a system can be considered as intermediate between those of classical transmission mains and distribution systems because of its several branches. A Lagrangian model simulating pressure wave propagation is used to evaluate the pipe pressure wave speed – associated with a genetic algorithm – and to locate possible anomalies – associated with wavelet analysis. The results of the diagnosis of the pipe system are corroborated by repairs executed by MM in the area where possible anomalies have been pre-localized.
1 November 2007 in Journal of Hydraulic Engineering
Transient tests can be reliably used for the diagnosis of pressurized pipe systems. As a matter of fact, the pressure signals acquired during these tests can reveal the presence of anomalies, e.g., leaks, since any irregularity in the pipe gives rise to reflected waves which in turn create discontinuities in the observed signal at the measurement section. In order to make the most of the interpretation of the pressure signals, as well as to improve the effectiveness of the location of leaks, wavelet analysis—a powerful tool within the realm of harmonic analysis—can be used. It aids in the diagnosis of pressure pipe systems by better exposing pressure signal discontinuities and precisely determining the arrival time of the pressure waves reflected by leaks, thus locating the leak itself. Since many wavelet transforms are available and the choice is driven by the specific application, both continuous and discrete wavelet transforms are considered in the paper, comparing different mother wavelets. Then the r...
Partial blockages commonly exist in pressurized pipeline systems, and the rapid remediation of such faults is required to reduce the wastage of energy as well as to maintain the serviceability of the pipe network. Numerous transient test–based techniques (TTBT) have been developed for detecting pipe defects, with each technique providing different advantages. Two previously developed techniques—pressure signal analysis (PSA) and frequency response analysis (FRA)—are experimentally tested in this study on systems of different pipe material and characteristics. Each method is validated using the experimental data, and the results show that PSA is most accurate for locating the blockage while FRA is most accurate for determining the radial constriction and length of the blockage section. To take advantage of the different strengths of the techniques, a coupling of the two methods is proposed. Experimental application results reveal that both detection accuracy and calculation efficiency are improved ...
1 June 2019 in Mechanical Systems and Signal Processing