Flocculation by chemicals can adequately reduce the clogging effect, and the bending effect of prefabricated vertical drains can be eliminated by laying a prefabricated drain in the horizontal direction. Various settling column tests with different contents of chemicals, polyacrylamide (PAM) and hydrated lime (Ca(OH)2), were initially conducted to find the optimum dose for the fastest settling. Then, the combined effect of using both PAM and lime on the dewatering behavior of dredged clay slurry is studied using a prefabricated horizontal drain (PHD) and vacuum pressure of 80 kPa. Initially, sedimentation and self-weight consolidation with the optimum dose of PAM and lime are allowed to occur, and then further vacuum preloading is carried out. The combined effect of lime and PAM is very effective in increasing the dewatering rate, taking only 207 hours in comparison to 247 hours for the soil slurry treated with only PAM and 411 hours for the soil slurry without any chemicals. After the treatment, the shear strength substantially increases to 58.5 kPa for the soil with lime and PAM in comparison to 42.8 kPa for the soil with PAM only and 16 kPa for the soil without any chemicals.
The horizontal strain in the vacuum preloading/dewatering of dredged slurry is significant to the apparent clogging effect and estimation of surface settlement around a drain; however, it has seldom been investigated in previous studies. In this study, a vacuum consolidation model test assisted by particle image velocimetry (PIV) technology was conducted. The displacement vector field was obtained through PIV analysis and image processing; it was used to visually observe the deformation features around a drain. Based on the displacement field, the vertical/horizontal strains at varied radial distances were calculated to explain the ‘soil pile’ and apparent clogging effect. From the strain distribution with radial distances, a significant lateral compression zone near the drain and an extension zone at farther areas were confirmed. Furthermore, a simple explicit model was established to evaluate the horizontal strain within a prefabricated vertical drain unit cell considering a horizontal attenuated vacuum and compression/extension zone. Finally, this method was applied to predict the horizontal displacement in the model test. The results showed that the proposed method can estimate the lateral displacement of soft clay slurry fairly well.
Safe, economical and high-quality storage of huge amount of grain for a longer duration under COVID-19 is a challenge and underground storage is a good alternative due to stable temperature, less cooling consumption and better pest control effect. However, the underground silo has very high requirement of waterproof and the performance of underground silo under combined compression and water pressure was rarely studied. In this study, a new composite structure, polypropylene – concrete wall (PPCW) for underground silo was proposed. Total three PPCWs with different size were manufactured to test the waterproofing features under joint effect of compression and hydropower of water. The strains, lateral displacement and cracking conditions of PPCWs were investigated. According to the experimental results, the PP board and concrete presented very good performance of interaction working under compression. The maximum water pressure of the specimens with stud spacing of 250mm increased by about 15.7% compared with that of the specimens with stud spacing of 350mm. The welding and strength of PP board has the greatest influence on the ultimate performance of PPCW. Based on the empirical coefficient method of concrete flat-slab and tested results, a new modified method was proposed to predict the bending moment at mid-span of PPCW by using an adjustment coefficient, Rm. Considering this experimental case only, the adopting a Rm = 0.64 could control the relative errors between test and analysis under 15.6%.
The temperature and moisture content inside a grain pile are two important indicators for judging the safety of grain storage. To accurately predict the temperature and moisture content inside a grain pile, a numerical simulation was carried out of the drying process of a mesoscale wheat grain soil based on a thin-layer drying method, considering non-uniform porosity. The effectiveness of this method for wheat piles was verified through a comparison with the experimental data. The influence of different ventilation cage heights and ventilation temperatures on heat and moisture transfer in the wheat grain pile were also studied. The results show the following points. The numerical simulation method in this paper can effectively predict the temperature and moisture content of a wheat grain pile. The non-uniform porosity distribution model can better reproduce the state of ventilation during storage of wheat grain piles than the uniform porosity distribution model. The distribution patterns of flow lines in silos with different ventilation cage heights have certain similarities, but the high-speed airflow area will decrease as the height of the ventilation cage increases. Different ventilation temperatures will significantly affect the areas of high temperature and the rewetting inside a wheat grain pile.
This study explores the influence of different segregation configurations on the creep behaviors and mildew of maize. An inexpensive and easy‐to‐use system was designed, and three configurations of maize kernels distribution, i.e., uniform mixing (Mdm), alternating distribution (Mda), and segregated state distribution (Mds), with wet basis moisture content of 22.9%, were compressed under vertical pressure of 200 kPa through a one‐dimensional oedometer. The compression and creep behaviors were investigated using the strain/settlement–time results, and aerobic plate counting (APC) was performed to study the effect of distribution configuration on the mildew effect. A finite‐element model was established to simulate the temperature variation caused by physical environmental factors, and the heat production by fungi was quantified using the difference in temperature between simulation and test. The results indicate that the three‐element Schiffman model can represent the creep behavior of the maize with different distribution configurations. The average temperature of Mdm, Mda, and Mds were 7.53%, 12.98%, and 14.76% higher than the average room temperature, respectively. The aerobic plate count of Mdm, Mda, and Mds were 1.0 × 105, 2.2 × 105, and 8.8 × 105 cfu g−1 stored for 150 h, respectively. In general, the temperature and APC in segregated maize bulk are higher than uniform grain. The effectiveness of the numerical model was verified, and the heat production by maize bulk fungi was quantified using the test and numerical temperature difference. The average heat was the least in Mdm with 2.8 × 106 J m−3, and Mda and Mds were 1.7 and 2 times more than Mdm. And the heat was related to the segregation configurations and agreed very well with the APC and temperature results.
Breakage in maize kernels and vertical pressure in grains lead to the uneven distribution of grain bulk density, which easily causes undesired problems in terms of grain storage. The objective of this study was, therefore, to determine the compression and heat production of the whole kernel (WK) and half kernel (HK) under two different loadings, i.e., 50 and 150 kPa, in maize bulk. An easy-to-use element testing system was developed by modification of an oedometer, and an empirical–analytical–numerical method was established to evaluate fungal heat production, considering kernel breakage and vertical pressure. Based on the experimental results, it was found that breakage induced larger compression; the compression of HK was 62% and 58% higher than that of WK at 50 kPa and 150 kPa, respectively. The creep model of the Hooke spring–Kelvin model in series can be used to accurately describe the creep behavior of maize bulk. Fungi and aerobic plate counting (APC) were affected significantly by the breakage and vertical pressure. APC in HK was 19 and 15 times that of WK under 150 and 50 kPa, respectively. The heat released by the development of fungi was found to be directly related to the APC results. The average temperatures of WK and HK under 150 and 50 kPa were 11.1%, 9.7%, 7.9%, and 7.6% higher than the room temperature, respectively. A numerical method was established to simulate the temperature increase due to fungi development. Based on the numerical results, heat production (Q) by fungi was estimated, and the results showed that the Q in HK was 1.29 and 1.32 times that of WK on average under 150 and 50 kPa. Additionally, the heat production results agreed very well with the APC results.