Purpose: To investigate the bracket transfer accuracy of the indirect bonding technique (IDB). Methods: Systematic search of the literature was conducted in PubMed MEDLINE, Web of Science, Embase, and Scopus through November 2021. Selection Criteria: In vivo and ex vivo studies investigating bracket transfer accuracy by comparing the planned and achieved bracket positions using the IDB technique were considered. Information concerning patients, samples, and applied methodology was collected. Measured mean transfer errors (MTE) for angular and linear directions were extracted. Risk of bias (RoB) in the studies was assessed using a tailored RoB tool. Meta-analysis of ex vivo studies was performed for overall linear and angular bracket transfer accuracy and for subgroup analyses by type of tray, tooth groups, jaw-related, side-related, and by assessment method. Results: A total of 16 studies met the eligibility criteria for this systematic review. The overall linear mean transfer errors (MTE) in mesiodistal, vertical and buccolingual direction were 0.08 mm (95% CI 0.05; 0.10), 0.09 mm (0.06; 0.11), 0.14 mm (0.10; 0.17), respectively. The overall angular mean transfer errors (MTE) regarding angulation, rotation, torque were 1.13° (0.75; 1.52), 0.93° (0.49; 1.37), and 1.11° (0.68; 1.53), respectively. Silicone trays showed the highest accuracy, followed by vacuum-formed trays and 3D printed trays. Subgroup analyses between tooth groups, right and left sides, and upper and lower jaw showed minor differences. Conclusions and implications: The overall accuracy of the indirect bonding technique can be considered clinically acceptable. Future studies should address the validation of the accuracy assessment methods used.
This scoping review aims to provide a comprehensive summary of the current literature on 3D-printed orthodontic aligners. It was conducted following the Preferred Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. An electronic literature search was conducted across the PubMed, Embase, and Web of Science databases. After applying the inclusion criteria, a total of 46 eligible studies published until September 2024 were selected for qualitative synthesis. To date, scientific evidence is primarily available for Tera Harz TC (Graphy, Seoul, Republic of Korea), which is the only studied material approved for orthodontic tooth movements. Although additional materials were identified during the literature search, there is a lack of scientific studies regarding their characteristics and clinical use. This review highlights that while material properties and biocompatibility are of critical importance, the clinical efficacy and long-term safety of 3D-printed aligners require further investigation. Many studies exhibit significant variability in testing methodologies, making substantiated comparisons challenging. Moreover, the existing literature primarily comprises in vitro studies, with limited clinical trials assessing the effectiveness of 3D-printed aligners. Given the current gaps in knowledge and the evolving nature of this field, further well-designed controlled clinical studies are necessary to evaluate the clinical performance and safety of 3D-printed aligners. The findings underscore the need for standardized protocols and comprehensive reporting to enhance the reliability of future research in this area.
Background: The clinical outcome of aligner therapy is closely related to the precision of its setup, which can be manually or digitally fabricated. The aim of the study is to investigate the suitability of manual setups made for aligner therapy in terms of the precision of tooth movements. Methods: Six dental technicians were instructed to adjust each of eleven duplicate plaster casts of a patient models as follows: a 1 mm pure vestibular translation of tooth 11 and a 15° pure mesial rotation of tooth 23. The processed setup models were 3D scanned and matched with the reference model. The one-sample Wilcoxon signed-rank test (p < 0.05) was used for evaluation. Results: The overall precision of the translational movement covers a wide range of values from 0.25 to 2.26 mm (median: 1.09 mm). The target value for the rotation of tooth 23 was achieved with a median rotation of 9.76° in the apical-occlusal direction. Unwanted movements in the other planes also accompanied the rotation. Conclusions: A manual setup can only be fabricated with limited precision. Besides the very high variability between technicians, additional unwanted movements in other spatial planes occurred. Manually fabricated setups should not be favored for aligner therapy due to limited precision.
19 June 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Aim of this study was to determine the forces and moments during simulated initial orthodontic tooth movements using a novel biomechanical test setup. The test setup consisted of an industrial precision robot with a force-torque sensor, a maxillary model and a control computer and software. Forces and moments acting on the corresponding experimental tooth during the motion simulations were dynamically measured for two 0.016" NiTi round archwires (Sentalloy Light/Sentalloy Medium). Intrusive (#1), rotational (#2) and angular (#3) tooth movements were simulated by a control program based on the principle of force control and executed by the robot. The results were statistically analysed using K-S-test and Mann-Whitney U test with a significance level of α = 5%. Sentalloy Medium archwires generated higher forces and moments than the Sentalloy Light archwires in all simulations. In simulation #1 the mean initial forces/moments reached 1.442 N/6.781 Nmm for the Light archwires and 1.637 N/9.609 Nmm for the Medium archwires. In movement #2 Light archwires generated mean initial forces/moments of 0.302 N/-8.271 Nmm whereas Medium archwires generated 0.432 N/-9.653 Nmm. Simulation #3 showed mean initial forces/moments of -0.122 N/8.477 Nmm from the Light archwires compared to -0.300 N/11.486 Nmm for the Medium archwires. The measured forces and moments were suitable for initial orthodontic tooth movement in simulations #2 and #3, however inadequate in simulation #1. Reduced archwire dimensions (<0.016″) should be selected for initial leveling of vertical malocclusions.
Background: One of the main uses of artificial intelligence in the field of orthodontics is automated cephalometric analysis. Aim of the present study was to evaluate whether developmental stages of a dentition, fixed orthodontic appliances or other dental appliances may affect detection of cephalometric landmarks. Methods: For the purposes of this study a Convolutional Neural Network (CNN) for automated detection of cephalometric landmarks was developed. The model was trained on 430 cephalometric radiographs and its performance was then tested on 460 new radiographs. The accuracy of landmark detection in patients with permanent dentition was compared with that in patients with mixed dentition. Furthermore, the influence of fixed orthodontic appliances and orthodontic brackets and/or bands was investigated only in patients with permanent dentition. A t-test was performed to evaluate the mean radial errors (MREs) against the corresponding SDs for each landmark in the two categories, of which the significance was set at p < 0.05. Results: The study showed significant differences in the recognition accuracy of the Ap-Inferior point and the Is-Superior point between patients with permanent dentition and mixed dentition, and no significant differences in the recognition process between patients without fixed orthodontic appliances and patients with orthodontic brackets and/or bands and other fixed orthodontic appliances. Conclusions: The results indicated that growth structures and developmental stages of a dentition had an impact on the performance of the customized CNN model by dental cephalometric landmarks. Fixed orthodontic appliances such as brackets, bands, and other fixed orthodontic appliances, had no significant effect on the performance of the CNN model.
Background: The purpose of this study was to retrospectively evaluate and follow up a conservative treatment approach with functional orthodontic appliances for the management of mandibular condyle fractures in children and adolescent patients. Methods: Between 2020 and 2022, the treatment records of patients with mandibular condyle fractures receiving a functional orthodontic treatment (FOT) were evaluated. In addition to the clinical and functional findings, magnetic resonance images of the mandibular condyles and surrounding structures were assessed. Results: Out of 61 patients, 8 met the inclusion criteria. The follow-up examination records showed no functional limitations. In 75% of cases, mild midline deviations persisted (mean 1.1 mm) without significant alterations to the occlusal relationships. Magnetic resonance imaging (MRI) showed the remodeling of the condyles and the restitution of the ramus heights, even in dislocated and displaced fractures. In three cases, a partial displacement of the articular disc was observed at the follow-up. No differences in the remodeling patterns were noted depending on age, sex, or fracture location. Conclusions: A FOT led to favorable functional and morphologic outcomes, supporting the concept of a conservative functional approach in children and adolescent patients. Functional adjunctive therapy should be considered in the conservative treatment of mandibular condyle fractures in growing patients.