Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Space technology has an impact on many domains of activity on earth, including in the field of global health. With the recent adoption of the United Nations’ (UN) Sustainable Development Goals, which highlight the interdependence and possible synergies of different domains, it is useful to better characterize the relationship between space technology and global health. Objective: To identify the applications of space technologies to global health, the key stakeholders in the field as well as the gaps and challenges. Methods: We used a scoping review methodology, including a literature review and the involvement of stakeholders via self-administered questionnaires. A distinct search on several search engines was conducted for each of the four key technological domains that were previously identified by the UN Office for Outer Space Affair’s expert group on space and global health (domain A: remote sensing, B: global navigation satellite systems, C: satellite communication and D: human space flights). Themes in which space technologies are of benefit to global health were extracted. Key stakeholders as well as gaps, challenges and perspectives were identified. Results: 222 sources were included for domain A, 82 sources for domain B, 144 sources for domain C and 31 sources for domain D. 3 questionnaires out of 16 sent were answered. Global Navigation Satellite Systems (GNSS) and Global Information Systems were used for the study and forecasting of communicable and non-communicable diseases; Satellite communication and GNSS for disaster response; Satellite communication for telemedicine and tele-education; GNSS for autonomy improvement; access to healthcare, as well as for safe and efficient transportation. Various researches and technologies developed for inhabited space flights have been adapted for terrestrial use. Conclusions: Although numerous examples of space technology applications to global health exist, improved awareness, training and collaboration of the research community is needed.
19 January 2023 in Frontiers in Cardiovascular Medicine
Pelvic venous disorders (PeVD), sometimes referred to as pelvic congestion syndrome (PCS), widely impact affected patients–mainly young women’s quality of life, causing puzzling, uncomfortable symptoms sometimes requiring months or years to get an explanation, while simply remaining undiagnosed in other cases. Because pelvic pain is a non-specific symptom, an appropriate diagnosis requires a careful patient workup, including a correlation between history and non-invasive imaging. Invasive imaging is frequently required to confirm the diagnosis and plan treatment. Current therapeutic approaches principally rely on minimally invasive techniques delivered through endovascular access. However, while comprehensive descriptive classifications such as the symptoms-varices-pathophysiology (SVP) classification exist, universally accepted guidelines regarding therapy to apply for each SVP category are still lacking. This review strongly focuses on PeVD imaging and discusses available therapeutic approaches with regard to pathophysiological mechanisms. It proposes a new classification scheme assisting clinical decision-making about endovascular management to help standardize the link between imaging findings and treatment.
Objective: Development of spectral photon-counting computed tomography (SPCCT) for ultra-high-resolution coronary CT angiography (CCTA) has the potential to accurately evaluate the coronary arteries of very-high-risk patients. The aim of this study was to compare the diagnostic performances of SPCCT against conventional CT for quantifying coronary stenosis in very-high-risk patients, with invasive coronary angiography (ICA) as the reference method. Materials and Methods: In this prospective institutional review board–approved study, very-high-risk patients addressed for ICA following an acute coronary syndrome were consecutively included. CCTA was performed for each patient with both SPCCT and conventional CT before ICA within 3 days. Stenoses were assessed using the minimal diameter over proximal and distal diameters method for CCTA and the quantitative coronary angiography method for ICA. Intraclass correlation coefficients and mean errors were assessed. Sensitivity and specificity were calculated for a >50% diameter stenosis threshold. Reclassification rates for conventional CT and SPCCT were assessed according to CAD-RADS 2.0, using ICA as the gold standard. Results: Twenty-six coronary stenoses were identified in 26 patients (4 women [15%]; age 64 ± 8 years) with 19 (73%) above 50% and 9 (35%) equal or above 70%. The median stenosis value was 64% (interquartile range, 48%–73%). SPCCT showed a lower mean error (6% [5%, 8%]) than conventional CT (12% [9%, 16%]). SPCCT demonstrated greater sensitivity (100%) and specificity (90%) than conventional CT (75% and 50%, respectively). Ten (38%) stenoses were reclassified with SPCCT and one (4%) with conventional CT. Conclusions: In very-high-risk patients, ultra-high-resolution SPCCT coronary angiography showed greater accuracy, sensitivity, and specificity, and led to more stenosis reclassifications than conventional CT.
17 May 2025 in International Journal of Cardiology
The fat attenuation index (FAI) is a biomarker that has recently gained attention for reflecting perivascular inflammation in coronary arteries. We investigated the utility of the FAI in identifying high-risk coronary plaques responsible for sudden cardiac death (SCD). Using multiphase post-mortem CT angiography (MPMCTA), we analyzed culprit plaques from 35 individuals who died from acute coronary syndrome, comparing these to control vessels from within-subject unaffected coronary arteries, with FAI measurement. Histopathological examination of culprit plaques assessed intraplaque inflammation, adventitial inflammation, and vasa vasorum density. Perivascular FAI values were significantly higher in culprit lesions than control lesions, -62.5 ± 10.4 vs. -68.5 ± 7.2 HU, respectively (p = 0.003). However, no significant differences in FAI were found between culprit lesions with and without local histopathological inflammation (p = 0.378). Additionally, FAI values ≥ -70.1 HU were more common in culprit than control lesions, though this threshold did not reach statistical significance (p = 0.081). Other imaging biomarkers, including the napkin-ring sign (p = 0.049) and plaque enhancement (p = 0.024), were more closely associated with histopathological inflammation. Our findings support FAI as a surrogate marker of high-risk coronary artery disease, although more extensive studies are needed to confirm its predictive accuracy for SCD. Integrating FAI with routine coronary CT angiography features could improve risk stratification in clinical settings.
Background/Objectives: To evaluate the feasibility of reducing contrast volume in oncologic body imaging using dual-energy CT (DECT) by (1) identifying the optimal virtual monochromatic imaging (VMI) reconstruction using DECT and (2) comparing DECT performed with reduced iodinated contrast media (ICM) volume to single-energy CT (SECT) performed with standard ICM volume. Methods: In this retrospective study, we quantitatively and qualitatively compared the image quality of 35 thoracoabdominopelvic DECT across 9 different virtual monoenergetic image (VMI) levels (from 40 to 80 keV) using a reduced volume of ICM (0.3 gI/kg of body weight) to determine the optimal keV reconstruction level. Out of these 35 patients, 20 had previously performed SECT with standard ICM volume (0.3 gI/kg of body weight + 9 gI), enabling protocol comparison. The qualitative analysis included overall image quality, noise, and contrast enhancement by two radiologists. Quantitative analysis included contrast enhancement measurements, contrast-to-noise ratio, and signal-to-noise ratio of the liver parenchyma and the portal vein. ANOVA was used to identify the optimal VMI level reconstruction, while t-tests and paired t-tests were used to compare both protocols. Results: VMI60 keV provided the highest overall image quality score. DECT with reduced ICM volume demonstrated higher contrast enhancement and lower noise than SECT with standard ICM volume (p < 0.001). No statistical difference was found in the overall image quality between the two protocols (p = 0.290). Conclusions: VMI60 keV with reduced contrast volume provides higher contrast and lower noise than SECT at a standard contrast volume. DECT using a reduced ICM volume is the technique of choice for oncologic body CT.