A smart capacitive transducer (SCT) for high-frequency vibration (HFV) measurements was developed, featuring self-calibration for the improvement of measurement accuracy. Measurements using this transducer are performed by positioning it over a thin (10 µm) dielectric layer on a conductive surface. This method was shown to be a non-contact vibration measurement technique for solid surfaces at frequencies over 10 kHz. Auto-calibration is performed every time the SCT is placed on the object being measured. This reduces the influence of positioning and the object’s surface properties on the measurement results. For the transducer’s auto-calibration, a predefined vibration of the measurement electrode is induced. This is achieved using a waveguide excited by a piezo element. The diameter of the developed SCT is 5 mm, with a frequency range of 10 kHz to 1 MHz, an object HFV amplitude measurement resolution of several picometers, and a repeatability error of several percent.
This report analyzes the different standard methods of quantity measurement, which, when applied in the processes of receiving and transferring fuel quantities, lead to discrepancies and accounting losses. Three main factors contribute to these discrepancies: unavoidable errors of measuring devices (calibration uncertainty ranging from 0.1 to 0.5% at best), systematic errors due to non-applied corrections during transactions, and systematic errors due to different regulations, which result in inconsistent conversion rules applied throughout the entire purchase-production-sales chain. Modeling of air buoyancy effects showed that neglecting buoyancy correction can lead to measurable and economically significant discrepancies, especially in large-scale operations. The mass of light petroleum products can be underestimated by up to 0.15%, potentially resulting in approximately $3 million in annual financial losses for a medium-sized refinery processing 10,000 tonnes per day. These findings underscore the necessity of applying buoyancy corrections for conventional weighing, especially for liquid petroleum products (LPP) measured in open systems. Conversely, for LPG weighed in closed, pressurized containers, a constant correction factor (0.99985) applies, but its economic impact is negligible. Therefore, the study recommends omitting this LPG correction unless contractually required, to streamline processes and reduce complexity. Achieving result comparability throughout the entire petroleum supply chain requires implementing uniform quantity calculation provisions using calibrated instruments and standardized methods under different conditions. This necessitates that all measurement results are traceable to reference conditions (mass in vacuum, volume at +15 °C). The proposed algorithms for oil mass and volume measurement and recalculation highlight the need for unified international regulations and a robust system.
Reliable quantity measurements are essential to meet the needs of the public interest, health, environmental protection, and the global fair trade of petroleum products. This can only be ensured by accurate and regular calibration of the measuring instruments. The frequency of metrological supervision is differently legally regulated in different countries since there are no clear criteria for determining periodicity. This report presents an analysis of the metrological supervision of vertical and aboveground tanks (intended for oil products) in different countries and long-term data usage for supervision periodicity identification. The periodicity of metrological supervision procedures must be synchronised with technical repairs and must depend on the type and volume of the tank. Choosing the optimal periodicity frequency of different tanks can adjust the economic burden of metrological supervision considering the economic and environmental aspects that is presented in the report with suitable adaptations.