An Chen

Dr. An Chen


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
欢刘欢 刘
欢 刘
ACAn Chen
An Chen
KLKewen Liu
Kewen Liu
To reveal the influence mechanism of complex and thick lacustrine sedimentary strata on the bearing performance of large-diameter and ultra-long piles, experimental and numerical simulation studies were carried out in view of the special engineering properties of peat soil in the strata. Three test piles with a diameter of 1 m and lengths of 98 m, 93 m, and 92 m, respectively, were taken as the research objects. The bearing characteristic parameters were obtained through static load tests, and the influence laws of parameters such as the thickness of the weak layer, pile length and pile diameter in the peat soil layer were analyzed in combination with numerical simulation. The results show that in the geological conditions of thick lacustrine sedimentary strata, the Q-s curve of the ultra-long pile is steeply descending, and the ultimate bearing capacity is 28,800 kN, showing the characteristics of end-bearing friction piles. The side friction resistance of the pile shows a typical “triangle” distribution in the upper part and reaches the ultimate value in the middle and lower parts, presenting a multi-hump “R” shape distribution. When the thickness of the weak layer increases from 10 m to 30 m, the settlement increases sharply, and when it reaches 40 m, the settlement almost remains unchanged. The change of pile length has a relatively small impact on the bearing capacity and can be ignored in terms of settlement change. When the pile diameter increases from 0.5 m to 1.0 m, the settlement decreases sharply, and when the pile diameter exceeds 1.5 m, the settlement fluctuates very little. The research confirms that the change of pile diameter has the greatest impact on the ultra-long pile, followed by the thickness of the weak layer, and the pile length has the least impact. The research results can provide theoretical basis and technical support for the design and construction of large-diameter and ultra-long piles in similar complex lacustrine sedimentary strata.

2 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJian Meng
Jian Meng
JLJiawen Liu
Jiawen Liu
JFJun Fu
Jun Fu
KYKexin Yin
Kexin Yin
HZHan Zhou
Han Zhou
ACAn Chen
An Chen
The insufficient bearing capacity of the foundation at waste dumps can easily lead to landslides and other geohazards. At present, discrepancies between the calculated bearing capacity of such foundations and actual field performance are a major cause of these accidents. Therefore, further research into methods for accurately estimating the foundation bearing capacity of waste dumps to guide engineering practice is crucial for preventing such incidents. This study employs a combination of theoretical and case analysis to examine the current calculation methods. We discover that the calculated values are smaller than the actual values. Moreover, by taking into account both the upper load of the waste dumps and the bearing capacity of the lower foundation, we analyzed the main problems leading to the underestimation. In response to the aforementioned issues, this study suggests incorporating the Boussinesq equation into the calculation of the upper load to account for the load distribution across various slope forms and the diffusion and superposition of stress at different foundation positions and depths. Simultaneously, the foundation’s bearing capacity is calculated to increase with burial depth, aligning with the stress at different positions. Finally, a new method for calculating the bearing capacity of foundations at waste dumps was developed. The bearing capacities of the waste dump foundation and the weakest point determined using the proposed method are validated through a case study and FLAC3D numerical simulation. This study can provide a reference for calculating the bearing capacity of foundations in similar waste dumps.