Peter B Sporns

Prof. Dr. Peter B Sporns


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NHNoel van Horn
Noel van Horn
GBGabriel Broocks
Gabriel Broocks
RKReza Kabiri
Reza Kabiri
MKMichel C. Kraemer
Michel C. Kraemer
SCSoren Christensen
Soren Christensen
TFTobias Djamsched Faizy
Tobias Djamsched Faizy
The hypoperfusion intensity ratio (HIR) is associated with collateral status and reflects the impaired microperfusion of brain tissue in patients with acute ischemic stroke and large vessel occlusion (AIS-LVO). As a deterioration in cerebral blood flow is associated with brain edema, we aimed to investigate whether HIR is correlated with the early edema progression rate (EPR) determined by the ischemic net water uptake (NWU) in a multicenter retrospective analysis of AIS-LVO patients anticipated for thrombectomy treatment. HIR was automatically calculated as the ratio of time-to-maximum (TMax) > 10 s/(TMax) > 6 s. HIRs < 0.4 were regarded as favorable (HIR+) and ≥0.4 as unfavorable (HIR−). Quantitative ischemic lesion NWU was delineated on baseline NCCT images and EPR was calculated as the ratio of NWU/time from symptom onset to imaging. Multivariable regression analysis was used to assess the association of HIR with EPR. This study included 731 patients. HIR+ patients exhibited a reduced median NWU upon admission CT (4% (IQR: 2.1–7.6) versus 8.2% (6–10.4); p < 0.001) and less median EPR (0.016%/h (IQR: 0.007–0.04) versus 0.044%/h (IQR: 0.021–0.089; p < 0.001) compared to HIR− patients. Multivariable regression showed that HIR+ (β: 0.53, SE: 0.02; p = 0.003) and presentation of the National Institutes of Health Stroke Scale (β: 0.2, SE: 0.0006; p = 0.001) were independently associated with EPR. In conclusion, favorable HIR was associated with lower early edema progression and decreased ischemic edema formation on baseline NCCT.

Verified
Journal Article
Open access
PDF file
TRThilo Rusche
Thilo Rusche
HBHanns-Christian Breit
Hanns-Christian Breit
MBMichael Bach
Michael Bach
JWJakob Wasserthal
Jakob Wasserthal
JGJulian Gehweiler
Julian Gehweiler
PSPeter B Sporns
Peter B Sporns
Objectives: Ischemic stroke is a leading cause of mortality and acquired disability worldwide and thus plays an enormous health-economic role. Imaging of choice is computed-tomographic (CT) or magnetic resonance imaging (MRI), especially diffusion-weighted (DW) sequences. However, MR imaging is associated with high costs and therefore has a limited availability leading to low-field-MRI techniques increasingly coming into focus. Thus, the aim of our study was to assess the potential of stroke imaging with low-field MRI. Material and Methods: A scanner comparison was performed including 27 patients (17 stroke cohort, 10 control group). For each patient, a brain scan was performed first with a 1.5T scanner and afterwards with a 0.55T scanner. Scan protocols were as identical as possible and optimized. Data analysis was performed in three steps: All DWI/ADC (apparent diffusion coefficient) and FLAIR (fluid attenuated inversion recovery) sequences underwent Likert rating with respect to image impression, resolution, noise, contrast, and diagnostic quality and were evaluated by two radiologists regarding number and localization of DWI and FLAIR lesions in a blinded fashion. Then segmentation of lesion volumes was performed by two other radiologists on DWI/ADC and FLAIR. Results: DWI/ADC lesions could be diagnosed with the same reliability by the most experienced reader in the 0.55T and 1.5T sequences (specificity 100% and sensitivity 92.9%, respectively). False positive findings did not occur. Detection of number/location of FLAIR lesions was mostly equivalent between 0.55T and 1.5T sequences. No significant difference (p = 0.789–0.104) for FLAIR resolution and contrast was observed regarding Likert scaling. For DWI/ADC noise, the 0.55T sequences were significantly superior (p < 0.026). Otherwise, the 1.5T sequences were significantly superior (p < 0.029). There was no significant difference in infarct volume and volume of infarct demarcation between the 0.55T and 1.5T sequences, when detectable. Conclusions: Low-field MRI stroke imaging at 0.55T may not be inferior to scanners with higher field strengths and thus has great potential as a low-cost alternative in future stroke diagnostics. However, there are limitations in the detection of very small infarcts. Further technical developments with follow-up studies must show whether this problem can be solved.

2 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TRThilo Rusche
Thilo Rusche
HBHanns-Christian Breit
Hanns-Christian Breit
MBMichael Bach
Michael Bach
JWJakob Wasserthal
Jakob Wasserthal
JGJulian Gehweiler
Julian Gehweiler
PSPeter B Sporns
Peter B Sporns
Purpose: Accurate detection of cerebral microbleeds (CMBs) on susceptibility-weighted (SWI) magnetic resonance imaging (MRI) is crucial for the characterization of many neurological diseases. Low-field MRI offers greater access at lower costs and lower infrastructural requirements, but also reduced susceptibility artifacts. We therefore evaluated the diagnostic performance for the detection of CMBs of a whole-body low-field MRI in a prospective cohort of suspected stroke patients compared to an established 1.5 T MRI. Methods: A prospective scanner comparison was performed including 27 patients, of whom 3 patients were excluded because the time interval was >1 h between acquisition of the 1.5 T and 0.55 T MRI. All SWI sequences were assessed for the presence, number, and localization of CMBs by two neuroradiologists and additionally underwent a Likert rating with respect to image impression, resolution, noise, contrast, and diagnostic quality. Results: A total of 24 patients with a mean age of 74 years were included (11 female). Both readers detected the same number and localization of microbleeds in all 24 datasets (sensitivity and specificity 100%; interreader reliability ϰ = 1), with CMBs only being observed in 12 patients. Likert ratings of the sequences at both field strengths regarding overall image quality and diagnostic quality did not reveal significant differences between the 0.55 T and 1.5 T sequences (p = 0.942; p = 0.672). For resolution and contrast, the 0.55 T sequences were even significantly superior (p < 0.0001; p < 0.0003), whereas the 1.5 T sequences were significantly superior (p < 0.0001) regarding noise. Conclusion: Low-field MRI at 0.55 T may have similar accuracy as 1.5 T scanners for the detection of microbleeds and thus may have great potential as a resource-efficient alternative in the near future.