Background: β-blockers improve the prognosis of patients with cardiac failure due to left ventricular systolic dysfunction. The aim of this study was to assess the efficacy of β-blockers in patients with dysfunctional systemic right ventricle. Methods: Fourteen patients with systemic right ventricle following a Mustard or a Senning operation for the transposition of the great arteries, or congenitally corrected transposition were included in the study. All had a decreased systemic right ventricular ejection fraction despite having standard cardiac failure therapy. Quality of life, New York Heart Association class, aerobic capacity, and systemic right ventricular function were assessed before treatment with β-blockers and at the end of the follow-up period, mean of 12.8 months with a range from 3 to 36 months. Results: Change in New York Heart Association class was significant (p = 0.016). Quality of life improved significantly throughout the study from a median grade 2 with a range from 1 to 3 to a median grade 1 with a range from 1 to 2 (p = 0.008). Systemic right ventricular ejection fraction assessed by radionuclide ventriculography improved significantly from a median of 41% (range: 29–53%) to 49% (range: 29–62%; p = 0.031). However, the change in thee ejection fraction assessed by magnetic resonance imaging was not significant from a median of 29% (range: 12–47%) to 32% (range: 22–63%; p = 0.063). Conclusion: In patients with cardiac failure due to systemic right ventricular dysfunction, β-blockers improve New York Heart Association class, quality of life, and systemic right ventricular ejection fraction assessed by radionuclide ventriculography.
1 January 2015 in Archives of Cardiovascular Diseases
Between December 2014 and March 2021, 144 patients with aortic (Ao) or mitral (Mi) paravalvular leaks (PVLs) were enrolled at 21 sites in 10 countries. Safety data were available for 137 patients, who were included in the safety analysis fraction (SAF), 93 patients with Mi PVLs and 44 patients with Ao PVLs. The full analysis set (FAS) comprised 112 patients with available stratum (aortic/mitral leak) as well as baseline (BL), 180-day or later assessments (2 years). Procedural success (implantation of the device with a proper closure of the PVL, defined as reduction in paravalvular regurgitation of ≥one grade as assessed by echocardiography post implantation) was achieved in 91.3% of FAS patients with Mi PVLs and in 90.0% of those with Ao PVLs. The proportion of patients suffering from significant or severe heart failure (HF), classified as New York Heart Association (NYHA) class III/IV, decreased from 80% at baseline to 14.1% at 2-year follow-up (FAS). The proportion of FAS patients needing hemolysis-related blood transfusion decreased from 35.5% to 3.8% and from 8.1% to 0% in Mi patients and Ao patients, respectively. In total, 35 serious adverse events (SAEs) were reported in 27 patients (19.7%) of the SAF population. The SAEs considered possibly or probably related to the device included device embolization (three patients), residual leak (two patients) and vascular complication (one patient). During follow-up, 12/137 (8.8%) patients died, but none of the deaths was considered to be device-related. Patients implanted with the Occlutech Paravalvular Leak Device (PLD) showed long-lasting improvements in clinical parameters, including NYHA class and a reduced dependency on hemolysis-related blood transfusions.