Lin Zhou

Lin Zhou

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2016 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
LZLin Zhou
Lin Zhou
ZLZhenghong Li
Zhenghong Li
ZWZhen Wang
Zhen Wang
CLChuan Liang
Chuan Liang
MLMingjia Li
Mingjia Li
YCYanyun Chu
Yanyun Chu
The linear-transformer-driver (LTD) is a recently developed pulsed-power technology that shows great promise for a number of applications. These include a Z-pinch-driven fission-fusion-hybrid reactor that is being developed by the Chinese Academy of Engineering Physics. In support of the reactor development effort, we are planning to build an LTD-based accelerator that is optimized for driving wire-array Z-pinch loads. The accelerator comprises six modules in parallel, each of which has eight series 0.8-MA LTD cavities in a voltage-adder configuration. Vacuum transmission lines are used from the interior of the adder to the central vacuum chamber where the load is placed. Thus the traditional stack-flashover problem is eliminated. The machine is 3.2 m tall and 12 m in outer diameter including supports. A prototype cavity was built and tested for more than 6000 shots intermittently at a repetition rate of 0.1 Hz. A novel trigger, in which only one input trigger pulse is needed by utilizing an internal trigger brick, was developed and successfully verified in these shots. A full circuit modeling was conducted for the accelerator. The simulation result shows that a current pulse rising to 5.2 MA in 91 ns (10%–90%) can be delivered to the wire-array load, which is 1.5 cm in height, 1.2 cm in initial radius, and 1 mg in mass. The maximum implosion velocity of the load is 32  cm/μs when compressed to 0.1 of the initial radius. The maximum kinetic energy is 78 kJ, which is 11.7% of the electric energy stored in the capacitors. This accelerator is supposed to enable a radiation energy efficiency of 20%–30%, providing a high efficient facility for research on the fast Z pinch and technologies for repetition-rate-operated accelerators.

22 December 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LZLin Zhou
Lin Zhou
MYMingtian Ye
Mingtian Ye
JLJian Lu
Jian Lu
SMShijian Meng
Shijian Meng
FYFan Ye
Fan Ye
ZLZhenghong Li
Zhenghong Li
This work is presenting the modeling of and the experimental studies performed on multi-gap gas switch (MGS) designed for linear transformer drivers (LTD). The MGS employs corona discharge in dry air for voltage grading across its six gaps, and therefore, achieves compactness and environmentally friendliness. Circuit modeling of the MGS was performed, followed by analysis and tests on corona current and voltage grading, showing a good self-break property of the switch. Trigger properties of the MGS were subsequently analyzed and experimentally investigated. The modeling and analysis were verified by evaluation experiments. The MGS was fired for 10 020 shots in a typical LTD brick with a charging voltage of $\pm$ 90 kV, which is 60% of the self-break voltage of the MGS when pressurized with 3.13 ata dry air, and a peak discharging current of 23.7 kA. The standard deviation of the time-delays between the trigger voltage and the discharging current is 3.3 ns for all the shots, during which only one pre-fire of the MGS occurred.

1 July 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GZGuangyi Zhao
Guangyi Zhao
XLXiangyang Liu
Xiangyang Liu
CWCong Wu
Cong Wu
YCYanyun Chu
Yanyun Chu
SJShuqing Jiang
Shuqing Jiang
TWTengfang Wang
Tengfang Wang
A high voltage power supply system for a compact neutron generator is developed. A four-stage symmetrical Cockcroft–Walton voltage multiplier circuit is adopted to produce 300 kV direct current high voltage. A two-stage 360 kV isolation transformer system is used to drive the ion source power supply. The high voltage power supply and the isolation transformer system are integrated in an epoxy bucket with a size of ϕ360 × 700 containing No. 25 transformer oil. The maximum output voltage of the power supply can reach 300 kV. The variation in the high voltage power supply is less than 0.5% when the power supply works at 300 kV/6 mA with an input voltage variation of ±8%. Meanwhile, the isolation transformer system can withstand more than 360 kV, with its output power being about 2.5 kW. No overvoltage protection devices are used in the power supply, and the protection resistors are connected in series to two pairs of rectifiers at the highest and lowest potential terminals and to the output terminal of the voltage multiplier to prevent overcurrent.

1 December 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LZLin Zhou
Lin Zhou
MYMingtian Ye
Mingtian Ye
JQJianming Qi
Jianming Qi
YCYanyun Chu
Yanyun Chu
ZWZhen Wang
Zhen Wang
A compact nanosecond pulse generator was developed, aiming at producing high-energy flash x rays with a long lifetime. The generator was designed on the basis of a 0.67-ns pulse forming line (PFL), which is charged to ∼700 kV by an air core Tesla transformer and switched by a fast spark gap. The Tesla transformer consists of a single turn primary coil surrounding a 44-turn secondary coil using no magnetic cores. 2D magnetostatic and electrostatic simulations were carried out, and the inductance and stray capacitance of the transformer were calculated. The transformer was powered by a 40-nF capacitor bank via a hydrogen thyratron. An effective coupling co-efficiency keff of 0.55 was achieved. The PFL voltage reached its second peak of 680 kV in 395 ns when the capacitor bank was switched at 25 kV. A nanosecond pulse with a peak voltage of 510 kV, a peak power of 2.6 GW, and a pulse width of 2.1 ns was generated on a 100-Ω ceramic resistor, which is going to be replaced by a vacuum x-ray tube. Since the pulse energy is small, the x-ray tube is expected to have a long lifetime. The generator is 285 mm in diameter, 800 mm in length, and 35 kg in weight, providing a compact means for high-energy x-ray radiographies both in scientific research and industrial applications.

26 January 2021 in Molecular Physics
Verified
Journal Article
Closed access
YCYu Cao
Yu Cao
YCYanyun Chu
Yanyun Chu
ZWZhen Wang
Zhen Wang
JQJianming Qi
Jianming Qi
LZLin Zhou
Lin Zhou
ZLZhenghong Li
Zhenghong Li
The low-density polystyrene is often chosen as the converter material in high energy density physics experiments. The accurate thermodynamic and transport properties of polystyrene under extreme conditions are necessary for reliable magneto-hydrodynamic simulations. Based on the ReaxFF molecular dynamics (RMD) simulation, the equation of state, thermal conductivity, atomic structure, and self-diffusion coefficient of low-density polystyrene have been investigated across a wide range of temperatures (1000–10,000 K) and densities (0.01–3.4 g/cm3). The results using RMD calculations considering the bond dissociation of polystyrene along with the principal Hugoniot curve show good agreement with experimental and the SESAME model. The transport properties (self-diffusion coefficient) from the corresponding microscopic time autocorrelation functions are obtained using RMD simulation, and the thermal conductivities are calculated using non-equilibrium molecular dynamic simulation. By investigating the bond dissociation of polystyrene, the stable H–H bond is found to be affected greatly by high temperatures and pressures. The calculation results can be helpful for future theoretical and experimental studies in high energy density research. GRAPHICAL ABSTRACT

2 August 2018 in Fusion Engineering and Design
Verified
Journal Article
Closed access
JQJ.M. Qi
J.M. Qi
ZWZ. Wang
Z. Wang
YCY.Y. Chu
Y.Y. Chu
LZLin Zhou
Lin Zhou
CLC. Liang
C. Liang
ZLZ.H. Li
Z.H. Li