1 August 2020 in Physics of Plasmas
The effects of spatial nonuniformity of electron multibeam emission on the output characteristics of a coaxial multibeam Ka-band relativistic klystron amplifier (RKA) are investigated using particle-in-cell simulations. The spatial nonuniformity is simulated using four different electron multibeam emission models, with (1) a continuous cathode non-emission area, (2) discontinuous cathode emission areas, (3) discontinuous cathode emission areas with different electron emission current densities, and (4) cathode emission areas with different and time-varying electron emission current densities. The simulation results with the first model show that the output microwave power of the RKA decreases as the continuous non-emission area increases, but that size of the continuous non-emission area has little effect on the frequency and pulse width of the RKA. The results with the second model show that the more uniform the electron current density in the discontinuous emission areas, the greater the output microwave power. The results with the third model show that the more uniform the distribution of the Z component of the induced electromagnetic field in the discontinuous emission areas, the greater the output microwave power, and also that the output microwave power increases as this Z component increases. The results with the fourth model show that fluctuations in the electron current density in the discontinuous emission areas in the steady-state phase of RKA operation cause fluctuations in both microwave frequency and output microwave power and that these fluctuations increase as the fluctuations in electron current density become stronger and as they become more rapid.
1 July 2020 in Review of Scientific Instruments
A high voltage power supply system for a compact neutron generator is developed. A four-stage symmetrical Cockcroft–Walton voltage multiplier circuit is adopted to produce 300 kV direct current high voltage. A two-stage 360 kV isolation transformer system is used to drive the ion source power supply. The high voltage power supply and the isolation transformer system are integrated in an epoxy bucket with a size of ϕ360 × 700 containing No. 25 transformer oil. The maximum output voltage of the power supply can reach 300 kV. The variation in the high voltage power supply is less than 0.5% when the power supply works at 300 kV/6 mA with an input voltage variation of ±8%. Meanwhile, the isolation transformer system can withstand more than 360 kV, with its output power being about 2.5 kW. No overvoltage protection devices are used in the power supply, and the protection resistors are connected in series to two pairs of rectifiers at the highest and lowest potential terminals and to the output terminal of the voltage multiplier to prevent overcurrent.
1 September 2024 in AIP Advances
Relativistic backward wave oscillators (RBWOs) have the characteristics of high power and high repetition rate. Reducing the magnetic field strength and the weight of the external permanent magnet (PM) is a significant development direction of RBWOs. In previous research, an X-band RBWO enclosed with a PM has achieved a power efficiency of 50%. However, the PM used in these papers requires a magnetic field magnitude of over 0.68 T, which leads to a weight exceeding 400 kg. The RBWO designed in this paper operates in coaxial TM01 mode, and the radial distance between its cathode and the surface of the slow wave structures reaches 7 mm. Under the condition of a low magnetic field, this design can provide a wide electron beam channel to avoid the rubbing of the electron beam envelope on the inner and outer conductors. Particle-in-cell simulation results have demonstrated that this RBWO achieves an output microwave power of 3 GW with a power efficiency of 50% enclosed in a PM with a magnetic field strength of 0.43 T and a weight of 74 kg.
1 August 2020 in AIP Advances
An experimental study of an intense current electron beam diode with a foil-free annular graphite cathode is carried out. The explosive emission images of a graphite cathode at discharging voltages of 240 kV and 780 kV and the attenuation images of cathode carbon ions at different magnetic fields are recorded using a 24-framing camera for the first time. The experimental results show that when the discharging voltage is 240 kV, the light spots of the plasma generated by the explosive emission process are randomly distributed over the annular cathode and the size and brightness of the light spots of the plasma are also randomly distributed; when the discharging voltage is 780 kV, if the background light generated by Čerenkov radiation is not taken into account, the light spots of the plasma generated by the explosion emission is more uniform than that when the discharging voltage is 280 kV and the brightness of the light spots of the plasma is higher, too. Meanwhile, when the axial magnetic field strength is less than 0.77 T, the plasma spots appear in the gap between the cathode and the anode. The smaller the axial magnetic field strength is, the higher the brightness of the plasma spots will be. In addition, when the discharging voltage is 780 kV/200 ns and the axial magnetic field strength is 0.77 T, a rough calculation indicates that the axial diffusion velocity of the cathode carbon ions ranges from 1.77 cm/μs to 2.1 cm/μs.
1 December 2023 in Review of Scientific Instruments
The electromagnetic characteristics of the input cavity with electron beams loaded are measured successfully in an X-band triaxial relativistic klystron amplifier (TKA) with a high frequency electrical probe. To solve the frequency response issue in the X band, a coaxial electrical probe is optimized and inserted obliquely into the input cavity at the designed angle so that the microwaves in the cavity can be sampled and extracted with the required coupling coefficient while the probe does not interfere with the solenoid coil, which is tightly integrated outside the TKA. Besides, the TKA is redesigned as a structure integrally sealed by the solenoid coil, and the secondary sealing induced by probe insertion is implemented on the flange of the solenoid coils rather than on the wall of the TKA, which is conducive to simplifying the coupling structure while maintaining the high vacuum level. The design is examined in a GW level TKA experiment, indicating that microwaves with a power of about 670 MW are generated in the input cavity at a frequency of 8.40 GHz, which is completely consistent with the injected and output microwave frequencies.
1 October 2024 in Physics of Plasmas
This paper introduces a high-power broadband X-band klystron amplifier that achieves an output power of 157 MW and a 3 dB operating bandwidth of 6.7%. The amplifier employs an explosive emission diode with high impedance, which balances the requirements of high power and broadband. The multi-gap input and output cavities are designed to operate at two different longitudinal modes within the operating frequency band, resulting in a flat absorption rate and output efficiency. Moreover, an eight-stage stagger-tuned bunching section is implemented to achieve a uniform fundamental harmonic current modulation depth across the frequency band. Simulation results indicate that when the diode voltage is 550 kV and the beam current is 550 A, the amplifier can achieve a maximum power of 157 MW with an efficiency of 51.9% at the central frequency of 9.8 GHz. Furthermore, within the 3 dB operating bandwidth of 6.7% (670 MHz), the power output remains higher than 80 MW. This novel klystron amplifier structure exhibits exceptional performance in terms of bandwidth, power, and efficiency, thus validating the effectiveness of the design in enhancing bandwidth and providing a solid foundation for the broadband design of high-power microwave sources.