Radu Badea

Radu Badea


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2022 in The Ultrasound Journal
Verified
Journal Article
Open access
PDF file
RHRichard A. Hoppmann
Richard A. Hoppmann
JMJeanette Mladenovic
Jeanette Mladenovic
LMLawrence Melniker
Lawrence Melniker
RBRadu Badea
Radu Badea
MBMichael Blaivas
Michael Blaivas
HMHassan Mustafa
Hassan Mustafa
Objectives: The purpose of this study is to provide expert consensus recommendations to establish a global ultrasound curriculum for undergraduate medical students. Methods: 64 multi-disciplinary ultrasound experts from 16 countries, 50 multi-disciplinary ultrasound consultants, and 21 medical students and residents contributed to these recommendations. A modified Delphi consensus method was used that included a systematic literature search, evaluation of the quality of literature by the GRADE system, and the RAND appropriateness method for panel judgment and consensus decisions. The process included four in-person international discussion sessions and two rounds of online voting. Results: A total of 332 consensus conference statements in four curricular domains were considered: (1) curricular scope (4 statements), (2) curricular rationale (10 statements), (3) curricular characteristics (14 statements), and (4) curricular content (304 statements). Of these 332 statements, 145 were recommended, 126 were strongly recommended, and 61 were not recommended. Important aspects of an undergraduate ultrasound curriculum identified include curricular integration across the basic and clinical sciences and a competency and entrustable professional activity-based model. The curriculum should form the foundation of a life-long continuum of ultrasound education that prepares students for advanced training and patient care. In addition, the curriculum should complement and support the medical school curriculum as a whole with enhanced understanding of anatomy, physiology, pathophysiological processes and clinical practice without displacing other important undergraduate learning. The content of the curriculum should be appropriate for the medical student level of training, evidence and expert opinion based, and include ongoing collaborative research and development to ensure optimum educational value and patient care. Conclusions: The international consensus conference has provided the first comprehensive document of recommendations for a basic ultrasound curriculum. The document reflects the opinion of a diverse and representative group of international expert ultrasound practitioners, educators, and learners. These recommendations can standardize undergraduate medical student ultrasound education while serving as a basis for additional research in medical education and the application of ultrasound in clinical practice.

30 August 2018 in Medical Ultrasonography
Verified
Journal Article
Open access
PDF file
BPBogdan Procopet
Bogdan Procopet
PFPetra Fischer
Petra Fischer
AHAdelina Horhat
Adelina Horhat
EMEmil Moiş
Emil Moiş
HSHoria Stefanescu
Horia Stefanescu
NHNadim Al Hajjar
Nadim Al Hajjar
The evaluation of patients with early hepatocellular carcinoma (HCC) referred for liver resection is still a matter of debate. Aims: 1) to compare liver stiffness measurement (LSM) by transient elastography with hepatic venous pressure gradient (HVPG) in the prediction of decompensation after liver resection in patients with cirrhosis and early HCC; 2) to identify which definition for posthepatectomy liver failure is better associated with survival.Material and methods: Fifty-one patients (MELD score of 10±3) were included. In this group, 34 patients underwent HVPG measurement, of which 13 (38%) had clinically significant portal hypertension (CSPH) and 35 patients underwent LSM (21.8±17.9 kPa). The study’s end-points were: posthepatectomy liver failure (PHLF) defined according to International Study Group of Liver Surgery criteria and 3-month decompensation defined as de novo ascites, variceal bleeding, jaundice, hepatic encephalopathy and acute kidney injury. The performance of LSM compared to HVPG in predicting the end-points were assessed by AUROC curves and accuracy.Results: Twenty (39%) patients developed PHLF and 15 (29%) developed decompensationat 3 months. Three-month decompensation tended to be better correlated with survival. LSM performed well in predicting decompensation at 3 months (AUROC=0.78, 95%CI: 0.63-0.94; p=0.01), comparable with HVPG (AUROC=0.89, 95%CI: 0.79-1.00; p<0.01) (DeLong test p=0.21). LSM was not sufficiently accurate to predict PHLF.Conclusion: LSM has a similar performance to HVPG in predicting decompensation at 3 months in patients with early HCC submitted to liver resection. Three-month decompensation is better associated with survival.

22 April 2021 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
Roxana SirliRoxana Sirli
Roxana Sirli
Ioan SporeaIoan Sporea
Ioan Sporea
Alina PopescuAlina Popescu
Alina Popescu
MDMIRELA DANILA
MIRELA DANILA
DSDaniela Larisa D Sandulescu
Daniela Larisa D Sandulescu
RBRadu Badea
Radu Badea
Aim: Contrast-enhanced ultrasound (CEUS) has become a relevant imaging method for the evaluation of focal liver le-sions (FLL). The aim of this study was to evaluate the performance of CEUS for the assessment of focal nodular hyperplasia (FNH) in a large study group. Material and methods: We performed a multicentre prospective observational study, which included successive CEUS examinations from fourteen Romanian centres. CEUS examinations were performed in de novo FLL, using low mechanical index ultrasound, following an intravenous bolus of 2.4 ml SonoVue. CEUS was considered conclusive for FNH if a typical pattern was present following contrast (rapid “spoke-wheel” enhancement during the arterial phase, hyperenhanced lesion during venous phase, hyper- or isoenhanced in the late phase). In all cases a reference method was available (contrast enhanced CT or MRI or biopsy). The trial was registered in clinicaltrials.gov (Identifier NCT01329458). Results: During the 6 years study, 2062 “de novo” FLL were evaluated by CEUS. From this cohort, 94/2062 (4.5%) had a typical enhancing pattern for FNH as described in the EFSUMB guidelines. Contrast enhanced CT/MRI and biopsy diagnosed additional 15 FNH. From the 94 cases diagnosed as FNH by CEUS, in nine the final diagnosis was different (five of them adenomas). CEUS had 85% sensitivity, 99.5% specificity, 90.4% positive predictive value, 99.2% negative predictive value and 98.8% diagnostic accuracy for the diagnosis of FNH. Conclusions: CEUS is a sensitive and very specific method for the diagnosis of FNH.

5 December 2020 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
ABAdrian Bartos
Adrian Bartos
IIIoana Iancu
Ioana Iancu
LCLidia Ciobanu
Lidia Ciobanu
RBRadu Badea
Radu Badea
Zeno SpârchezZeno Spârchez
Zeno Spârchez
Dana IancuDana Iancu
Dana Iancu
This paper summarizes the current knowledge of intraoperative ultrasonography (IOUS) in open and laparoscopic ab-dominal surgery. The abdominal IOUS contributes to the diagnosis and staging (for parenchymal organ tumors), to establish surgical procedure and to guide surgical maneuvers. The main applications are represented by liver, biliary tract and pancreatic pathology. Diagnostic approaches are frequently combined with therapeutic purposes. The technique, equipment, training, benefits and limits of IOUS in abdominal surgery are discussed and cases from our experience are used as examples.

14 March 2021 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
AMAnita Roxana Maxim
Anita Roxana Maxim
OGOvidiu Horia Gligor
Ovidiu Horia Gligor
RBRadu Badea
Radu Badea
Comparison of Hystero-salpingography and Hysterosalpingo-Contrast Sonography for tubal patency testing: technical success, pain perception, side effects and complications

5 September 2020 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
FEFlorin Ioan Elec
Florin Ioan Elec
AEAlina Daciana Elec
Alina Daciana Elec
Sorana D. BolboacăSorana D. Bolboacă
Sorana D. Bolboacă
MSMihai Adrian Socaciu
Mihai Adrian Socaciu
AMAdriana Milena Muntean
Adriana Milena Muntean
RBRadu Badea
Radu Badea
Aim: Our study aimed to assess the usefulness of contrast-enhanced ultrasound (CEUS) in the initial evaluation of the graft function.Materials and method: A cross-sectional study was conducted in the early postoperative period on patients with kidney transplantation, between September 2017 to November 2018. Two groups of patients were investigated; delayed graft function (DGF) and early graft function (EGF). All patients were examined by grey scale, Doppler ultrasound and CEUS.Results: Nineteen patients, aged from 23 to 64 years (mean age 50 years), 7 in the DGF group and 12 in the EGF group were evaluated. The resistive index (RI) show significantly higher values in the DGF group at the level of upper interlobar artery (p=0.025) and medium interlobar artery (p=0.02). The CEUS investigation shows a greater region of interest (ROI) area (p=0.02) and lower values for wash-out area under the curve (WoAUC) (p=0.047) and respectively wash-in and wash-out area under the curve (WiWoAUC) (p=0.031) for the DGF group. The quality of fit (QoF) proved lower in the DGF group either for evaluation of global graft (p=0.012), cortex (p=0.025), or medulla (p=0.009).A significant relationship among all patients was found between the glomerular filtration rate (GFR) [ml/min] and the renal artery fall time (FT) [s] (p=0.012), WoAUC [a.u.] (p=0.03), and WiWoAUC [a.u.] (p=0.024). The arterial QoF [%] was associated with the arterial ROI area (p=0.048).Conclusions: Intensity CEUS parameters WoAUC and WiWoAUC may be useful to diagnose and follow-up grafts with delayed function. Additional studies on larger cohorts are required for the recommendation of CEUS as a routine evaluation of the transplanted kidney.