Background: During cardiogenic shock blood circulation is minimal in the human body and does not suffice to survive. The extracorporeal life support system (ECLS) acts as a miniature heart-lung-machine that can be temporarily implanted over major vessels e.g. at the groin of the patient to bridge cardiogenic shock. To perform this procedure in an emergency, a proper training model is desirable. Therefore, a 3-dimensional-printable (3D) material must be found that mimics large vessel needle penetration properties. A suitable test bench for material comparison is desirable. Methods: A test setup was built, which simulated the clinically relevant wall tension in specimens. The principle was derived from an existing standardized needle penetration test. After design, the setup was fabricated by means of 3D printing and mounted onto an universal testing machine. For testing the setup, a 3D printable polymer with low Shore A hardness and porcine aorta were used. The evaluation was made by comparing the curves of the penetration force to the standardized test considering the expected differences. Results: 3D printing proved to be suitable for manufacturing the test setup, which finally was able to mimic wall tension as if under blood pressure and penetration angle. The force displacement diagrams showed the expected curves and allowed a conclusion to the mechanical properties of the materials. Although the materials forces deviated between the porcine aorta and the Agilus30 polymer, the graphs showed similar but still characteristic curves. Conclusions: The test bench provided the expected results and was able to show the differences between the two materials. To improve the setup, limitations has been discussed and changes can be implemented without complications.
For surgical catheterization training applications, realistic and effective materials are desired. In this study, the relevance of a needle puncture angle and a simulated wall stress on different elastic materials were determined in a previously developed experimental setup. Both settings were considered individually in two new setups. In addition, a control setup with neither angle nor prestress was designed. During the process of puncturing the samples of two materials (Replisil 9N and Formlabs Elastic 50A), force–displacement values were collected, and three predefined parameters evaluated. The differences between the angled/stressed groups and the control group were analyzed. The additively processed material required a significantly higher force to puncture than the conventional one (p < 0.001). Moreover, a needle angulation of 45° required more force than puncturing orthogonally. Prestressing the samples did not clearly influence the resulting force. An evaluation of relative parameters showed that the investigated materials behaved differently but not linearly differently under the influence of needle angle and prestress. Therefore, it is essential to evaluate the properties and suitability of materials for surgical training models in appropriate experimental setups considering multiple parameters.
30 August 2023 in Journal of Reproductive Immunology