Background. There are several in vitro testing options to investigate the efficacy of sports mouthguards. None of these represent everyday situations, but the effects of simple laws of physics can be observed. This enables the comparison of conventional materials for mouthguards towards fabrications from additive manufacturing. Methods. A ball-drop experiment measured the maximum force and temporospatial distribution of a vertical impact on six material groups and a reference group (No-MG). Three conventional materials (ethylenvinylacetate) with 1, 2, and 3 layers were compared with additively manufactured (AM) specimens of comparable layering with a respective thickness of 4 mm, 5 mm, and 6.8 mm. Results. A maximum force of 8982.35 N ± 305.18 (No-MG) was maximum damped to 2470.60 N ± 87.00 (conventional 6.8 mm) compared with 5585.09 N ± 203.99 (AM 6.8 mm) Thereby, the ratio between shock absorption per millimeter was best for 4 mm thickness with means of 1722 N (conventional) and 624 N (AM). Conclusions. Polymer layers demonstrated a force reduction up to 71.68%. For now, additively processed resins of comparable hardness and layering are inferior to conventional fabrications.
Conventionally and digitally manufactured removable complete dentures with different dentition forms were examined for manufacturing accuracy (trueness, precision), fracture forces under torsional loading and subsequent repairability. A total of 90 mandibular prostheses were manufactured. Ten were made using the injection molding technique and finished with prefabricated teeth. 40 bases each, were manufactured subtractively and additively. Digitally the prosthesis' dental arch was divided either into two quadrants or three sextants, or kept as full arch. Afterwards, ten additive and subtractive bases were finished with prefabricated teeth and ten of each with milled quadrants, sextants and full arches. After manufacturing, all specimens were rescanned for accuracy comparisons using the Root Mean Square (RMS). Lastly, all specimens were tested to failure under torsional loading. Conventionally manufactured dentures showed the greatest deviation in accuracy. The type of base manufacturing did not determine the fracture resistance of the prostheses. The dentition form had a significant influence. While prefabricated teeth (86.01 ± 19.76 N) and quadrants (77.89 ± 9.58 N) showed a low fracture resistance, sextants (139.12 ± 21.41 N) and full arches (141.05 ± 17.14 N) achieved the highest fracture forces. Subtractive bases with prefabricated teeth or quadrants were assessed to be repairable, digital dentures with full arch were assessed as not repairable. The presented testing set-up is suitable to determine the fracture behavior of dentures rather than of standards. With the possibility of digital design and individual manufacturing, dentures' mechanical stability can be significantly increased, especially with suitable dentition forms.
Background: Due to rapid changes in dental practice, digital technologies have become prominent in undergraduate dental education at German universities in recent years. This shift has prompted a re-evaluation of content as well as teaching methods, particularly in courses where students are prepared for patient treatment. Traditional training on standardized models with resin teeth cannot cover the complexity of individual dental arch configuration encountered in patient situations. This study explores the use of 3D printing technology to create individualized models for prosthetic treatment simulations, aiming to evaluate students’ feedback towards their experience with this training setting. Methods: First, the study describes the design and fabrication of individualized models with exchangeable teeth based on intraoral scans, mounted on connected plates with distance holders that can be fixed to standard phantom heads. Second, students provided feedback through a questionnaire, assessing various aspects such as the effectiveness of the 3D-printed models compared to traditional frasaco models for preparation exercises. Results: The results indicated that the design of the realized models was feasible for preparation training (question no. 4: 93% positive rating) and showed positive perceptions of the 3D-printed models, with students finding them effective for preparation exercises and beneficial in bridging the gap between simulation and real patient situations (question no. 6: 69% positive rating). Conclusions: The study suggests that 3D printing technology offers a valuable tool in dental education, providing realistic and patient-specific scenarios for students to enhance their skills and readiness for clinical practice. Further improvements in material properties in hand with cost-effective approaches are essential for widespread implementation.
Measuring the dimensions of personalized devices can provide relevant information for the production of future such devices used in various medical specialties. Difficulties with standardizing such measurement and obtaining high accuracy, alongside cost-intensive measuring methodologies, has dampened interest in this practice. This study presents a methodology for automatized measurements of personalized medical appliances of variable shape, in this case an orthodontic appliance known as Tübingen Palatal Plate (TPP). Parameters such as length, width and angle could help to standardize and improve its future use. A semi-automatic and custom-made program, based on Rhinoceros 7 and Grasshopper, was developed to measure the device (via an extraoral scanner digital file). The program has a user interface that allows the import of the desired part, where the user is able to select the necessary landmarks. From there, the program is able to process the digital file, calculate the necessary dimensions automatically and directly export all measurements into a document for further processing. In this way, a solution for reducing the time for measuring multiple dimensions and parts while reducing human error can be achieved.
For surgical catheterization training applications, realistic and effective materials are desired. In this study, the relevance of a needle puncture angle and a simulated wall stress on different elastic materials were determined in a previously developed experimental setup. Both settings were considered individually in two new setups. In addition, a control setup with neither angle nor prestress was designed. During the process of puncturing the samples of two materials (Replisil 9N and Formlabs Elastic 50A), force–displacement values were collected, and three predefined parameters evaluated. The differences between the angled/stressed groups and the control group were analyzed. The additively processed material required a significantly higher force to puncture than the conventional one (p < 0.001). Moreover, a needle angulation of 45° required more force than puncturing orthogonally. Prestressing the samples did not clearly influence the resulting force. An evaluation of relative parameters showed that the investigated materials behaved differently but not linearly differently under the influence of needle angle and prestress. Therefore, it is essential to evaluate the properties and suitability of materials for surgical training models in appropriate experimental setups considering multiple parameters.
Biodegradable zinc (Zn) has attracted increasing interest as a material for temporary implants, primarily due to its moderate degradation kinetics. In recent years, additive manufacturing of Zn alloys using the laser powder bed fusion method (L-PBF) has shown promising results. Compared to as-cast Zn alloys, it offers preferable customized solutions for patient-specific temporary biomedical implants. Due to the novelty of these printed degradable biomaterials and due to reported cytotoxic effects of Zn alloys, this study investigates additively manufactured ZnAgCu, ZnAgCuMn, and ZnAgCuTi alloys, both in as-printed and post-processed conditions, with a focus on L929 and SAOS-2 biocompatibility. In this work, we demonstrate that the increased porosity and therefore larger surface areas compared to polished Zn-alloy samples affect their biocompatibility. Minimal to no cell proliferation was observed on and near the Zn-alloy test plates after 24 h. Undiluted extracts from as-cast Zn and L-PBF-manufactured plates were initially cytotoxic to SAOS-2 cells. However, as passivation proceeded, cytocompatibility was significantly increased from day 3 onward. Zn2+ ion release peaked at 24 h and declined significantly from day 2 to day 10. Compared to the other Zn alloys, ZnAgCuMn exhibited the lowest cytocompatibility. Most intriguingly, 3-month surfaces exhibited reduced cytocompatibility to osteoblasts compared to freshly polished samples. The observed in vitro cytotoxicity motivates further investigation of as-printed and post-processed L-PBF-manufactured Zn alloys, aiming to develop novel surface modification strategies to mitigate the initial ion burst responsible for reduced cytocompatibility and to adjust and tailor the overall degradation kinetics to physiologically tolerable levels tailored to the intended clinical application.