Antonio Cervellino

Dr. Antonio Cervellino

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2015 in Nature
Verified
Journal Article
Closed access
PDF file
JMJarad A. Mason
Jarad A. Mason
JOJulia Oktawiec
Julia Oktawiec
MTMercedes K. Taylor
Mercedes K. Taylor
MHMatthew R. Hudson
Matthew R. Hudson
JRJulien Rodriguez
Julien Rodriguez
JLJeffrey R. Long
Jeffrey R. Long

10 April 2017 in ACS Nano
Verified
Journal Article
Open access
FBFederica Bertolotti
Federica Bertolotti
LPLoredana Protesescu
Loredana Protesescu
MKMaksym V. Kovalenko
Maksym V. Kovalenko
SYSergii Yakunin
Sergii Yakunin
ACAntonio Cervellino
Antonio Cervellino
AGAntonella Guagliardi
Antonella Guagliardi
Crystal defects in highy luminescent colloidal nanocrystals (NCs) of CsPbX3 perovskites (X = Cl, Br, I) are investigated. Here, using X-ray total scattering techniques and the Debye scattering equation (DSE), we provide evidence that the local structure of these NCs always exhibits orthorhombic tilting of PbX6 octahedra within locally ordered subdomains. These subdomains are hinged through a two-/three-dimensional (2D/3D) network of twin boundaries through which the coherent arrangement of the Pb ions throughout the whole NC is preserved. The density of these twin boundaries determines the size of the subdomains and results in an apparent higher-symmetry structure on average in the high-temperature modification. Dynamic cooperative rotations of PbX6 octahedra are likely at work at the twin boundaries, causing the rearrangement of the 2D or 3D network, particularly effective in the pseudocubic phases. An orthorhombic, 3D γ-phase, isostructural to that of CsPbBr3 is found here in as-synthesized CsPbI3 NCs.

16 July 2013 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
PWP. R. Willmott
P. R. Willmott
DMD. Meister
D. Meister
SLS. J. Leake
S. J. Leake
MLM. Lange
M. Lange
ABAnna Bergamaschi
Anna Bergamaschi
RWR. Wullschleger
R. Wullschleger
The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.

19 September 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
DMD. Martoccia
D. Martoccia
PWP. R. Willmott
P. R. Willmott
TBT. Brugger
T. Brugger
MBM. Björck
M. Björck
SGS. Günther
S. Günther
TGT. Greber
T. Greber
The structure of a single layer of graphene on Ru(0001) has been studied using surface x-ray diffraction. A surprising superstructure containing 1250 carbon atoms has been determined, whereby 25×25 graphene unit cells lie on 23×23 unit cells of Ru. Each supercell contains 2×2 crystallographically inequivalent subcells caused by corrugation. Strong intensity oscillations in the superstructure rods demonstrate that the Ru substrate is also significantly corrugated down to several monolayers and that the bonding between graphene and Ru is strong and cannot be caused by van der Waals bonds. Charge transfer from the Ru substrate to the graphene expands and weakens the C–C bonds, which helps accommodate the in-plane tensile stress. The elucidation of this superstructure provides important information in the potential application of graphene as a template for nanocluster arrays.

22 July 2010 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ABAnna Bergamaschi
Anna Bergamaschi
ACAntonio Cervellino
Antonio Cervellino
RDRoberto Dinapoli
Roberto Dinapoli
FGFabia Gozzo
Fabia Gozzo
BHBeat Henrich
Beat Henrich
XSXintian Shi
Xintian Shi
The MYTHEN single-photon-counting silicon microstrip detector has been developed at the Swiss Light Source for time-resolved powder diffraction experiments. An upgraded version of the detector has been installed at the SLS powder diffraction station allowing the acquisition of diffraction patterns over 120 degrees in 2theta in fractions of seconds. Thanks to the outstanding performance of the detector and to the calibration procedures developed, the quality of the data obtained is now comparable with that of traditional high-resolution point detectors in terms of FWHM resolution and peak profile shape, with the additional advantage of fast and simultaneous acquisition of the full diffraction pattern. MYTHEN is therefore optimal for time-resolved or dose-critical measurements. The characteristics of the MYTHEN detector together with the calibration procedures implemented for the optimization of the data are described in detail. The refinements of two known standard powders are discussed together with a remarkable application of MYTHEN to organic compounds in relation to the problem of radiation damage.

13 October 2010 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
Manuel HintersteinManuel Hinterstein
Manuel Hinterstein
Michael KnappMichael Knapp
Michael Knapp
MHMarkus Hölzel
Markus Hölzel
WJWook Jo
Wook Jo
ACAntonio Cervellino
Antonio Cervellino
HFHartmut Fuess
Hartmut Fuess