Anna Bergamaschi

Dr. Anna Bergamaschi

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2009 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
PKP. Kraft
P. Kraft
ABAnna Bergamaschi
Anna Bergamaschi
CBCh. Broennimann
Ch. Broennimann
RDR. Dinapoli
R. Dinapoli
EEE. F. Eikenberry
E. F. Eikenberry
BSB. Schmitt
B. Schmitt
PILATUS is a silicon hybrid pixel detector system, operating in single-photon-counting mode, that has been developed at the Paul Scherrer Institut for the needs of macromolecular crystallography at the Swiss Light Source (SLS). A calibrated PILATUS module has been characterized with monochromatic synchrotron radiation. The influence of charge sharing on the count rate and the overall energy resolution of the detector were investigated. The dead-time of the system was determined using the attenuated direct synchrotron beam. A single module detector was also tested in surface diffraction experiments at the SLS, whereby its performance regarding fluorescence suppression and saturation tolerance were evaluated, and have shown to greatly improve the sensitivity, reliability and speed of surface diffraction data acquisition.

16 July 2013 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
PWP. R. Willmott
P. R. Willmott
DMD. Meister
D. Meister
SLS. J. Leake
S. J. Leake
MLM. Lange
M. Lange
ABAnna Bergamaschi
Anna Bergamaschi
RWR. Wullschleger
R. Wullschleger
The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs.

1 August 2009 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
BHB. Henrich
B. Henrich
ABAnna Bergamaschi
Anna Bergamaschi
CBC. Broennimann
C. Broennimann
RDR. Dinapoli
R. Dinapoli
EEE.F. Eikenberry
E.F. Eikenberry
BSB. Schmitt
B. Schmitt

22 July 2010 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ABAnna Bergamaschi
Anna Bergamaschi
ACAntonio Cervellino
Antonio Cervellino
RDRoberto Dinapoli
Roberto Dinapoli
FGFabia Gozzo
Fabia Gozzo
BHBeat Henrich
Beat Henrich
XSXintian Shi
Xintian Shi
The MYTHEN single-photon-counting silicon microstrip detector has been developed at the Swiss Light Source for time-resolved powder diffraction experiments. An upgraded version of the detector has been installed at the SLS powder diffraction station allowing the acquisition of diffraction patterns over 120 degrees in 2theta in fractions of seconds. Thanks to the outstanding performance of the detector and to the calibration procedures developed, the quality of the data obtained is now comparable with that of traditional high-resolution point detectors in terms of FWHM resolution and peak profile shape, with the additional advantage of fast and simultaneous acquisition of the full diffraction pattern. MYTHEN is therefore optimal for time-resolved or dose-critical measurements. The characteristics of the MYTHEN detector together with the calibration procedures implemented for the optimization of the data are described in detail. The refinements of two known standard powders are discussed together with a remarkable application of MYTHEN to organic compounds in relation to the problem of radiation damage.

1 October 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JSJakub Szlachetko
Jakub Szlachetko
MNM. Nachtegaal
M. Nachtegaal
EBE. de Boni
E. de Boni
MWM. Willimann
M. Willimann
OSO. Safonova
O. Safonova
ALA. Lücke
A. Lücke
We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV–9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation that allows to preserve the spectrometer resolution and spectrometer efficiency. Application of the spectrometer for time-resolved resonant inelastic x-ray scattering and single-shot x-ray emission spectroscopy is demonstrated.

1 September 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RDRoberto Dinapoli
Roberto Dinapoli
ABAnna Bergamaschi
Anna Bergamaschi
BHBeat Henrich
Beat Henrich
RHRoland Horisberger
Roland Horisberger
IJIan Johnson
Ian Johnson
GTGerd Theidel
Gerd Theidel