Olga Kamanina

Dr. Olga Kamanina

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
OPO N Ponamoreva
O N Ponamoreva
OKOlga Kamanina
Olga Kamanina
VAV A Alferov
V A Alferov
AMAndrey Machulin
Andrey Machulin
TRT V Rogova
T V Rogova
EIElena Ivanova
Elena Ivanova

25 March 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
OKOlga Kamanina
Olga Kamanina
ESEvgeniya A. Saverina
Evgeniya A. Saverina
PRPavel Vladimirovich Rybochkin
Pavel Vladimirovich Rybochkin
Vyacheslav ArlyapovVyacheslav Arlyapov
Vyacheslav Arlyapov
AVAnatoly Vereshchagin
Anatoly Vereshchagin
Valentine AnanikovValentine Ananikov
Valentine Ananikov
Microorganism-cell-based biohybrid materials have attracted considerable attention over the last several decades. They are applied in a broad spectrum of areas, such as nanotechnologies, environmental biotechnology, biomedicine, synthetic chemistry, and bioelectronics. Sol-gel technology allows us to obtain a wide range of high-purity materials from nanopowders to thin-film coatings with high efficiency and low cost, which makes it one of the preferred techniques for creating organic-inorganic matrices for biocomponent immobilization. This review focuses on the synthesis and application of hybrid sol-gel materials obtained by encapsulation of microorganism cells in an inorganic matrix based on silicon, aluminum, and transition metals. The type of immobilized cells, precursors used, types of nanomaterials obtained, and their practical applications were analyzed in detail. In addition, techniques for increasing the microorganism effective time of functioning and the possibility of using sol-gel hybrid materials in catalysis are discussed.

8 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Pavel MelnikovPavel Melnikov
Pavel Melnikov
АААnastasia Аlexandrovskaya
Аnastasia Аlexandrovskaya
ANAlina O. Naumova
Alina O. Naumova
Vyacheslav ArlyapovVyacheslav Arlyapov
Vyacheslav Arlyapov
OKOlga Kamanina
Olga Kamanina
Nikolaj A. YashtulovNikolaj A. Yashtulov
Nikolaj A. Yashtulov
In the last decade, there has been continuous competition between two methods for detecting the concentration of dissolved oxygen: amerometric (Clark electrode) and optical (quenching of the phosphorescence of the porphyrin metal complex). Each of them has obvious advantages and disadvantages. This competition is especially acute in the development of biosensors, however, an unbiased comparison is extremely difficult to achieve, since only a single detection method is used in each particular study. In this work, a microfluidic system with synchronous detection of the oxygen concentration by two methods was created for the purpose of direct comparison. The receptor element is represented by Saccharomyces cerevisiae yeast cells adsorbed on a composite material, previously developed by our scientific group. To our knowledge, this is the first work of this kind in which the comparison of the oxygen detection methods is carried out directly.

11 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
LKLyubov Kuznetsova
Lyubov Kuznetsova
Vyacheslav ArlyapovVyacheslav Arlyapov
Vyacheslav Arlyapov
OKOlga Kamanina
Olga Kamanina
Elizaveta A. LantsovaElizaveta A. Lantsova
Elizaveta A. Lantsova
STSergei Tarasov
Sergei Tarasov
ARAnatoly Reshetilov
Anatoly Reshetilov
Electropolymerized neutral red, thionine, and aniline were used as part of hybrid nanocomposite conductive polymers, to create an amperometric reagent-less biosensor for glucose determination. The structure of the obtained polymers was studied using infrared (IR) spectroscopy and scanning electron microscopy. Electrochemical characteristics were studied by cyclic voltammetry and impedance spectroscopy. It was shown that, from the point of view of both the rate of electron transfer to the electrode, and the rate of interaction with the active center of glucose oxidase (GOx), the most promising is a new nanocomposite based on poly(neutral red) (pNR) and thermally expanded graphite (TEG). The sensor based on the created nanocomposite material is characterized by a sensitivity of 1000 ± 200 nA × dm3/mmol; the lower limit of the determined glucose concentrations is 0.006 mmol/L. The glucose biosensor based on this nanocomposite was characterized by a high correlation (R2 = 0.9828) with the results of determining the glucose content in human blood using the standard method. Statistical analysis did not reveal any deviations of the results obtained using this biosensor and the reference method. Therefore, the developed biosensor can be used as an alternative to the standard analysis method and as a prototype for creating sensitive and accurate glucometers, as well as biosensors to assess other metabolites.

12 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SKSaniyat Kurbanalieva
Saniyat Kurbanalieva
Vyacheslav ArlyapovVyacheslav Arlyapov
Vyacheslav Arlyapov
Anna KharkovaAnna Kharkova
Anna Kharkova
Roman PerchikovRoman Perchikov
Roman Perchikov
OKOlga Kamanina
Olga Kamanina
ARAnatoly Reshetilov
Anatoly Reshetilov
The possibility of the developing a biochemical oxygen demand (BOD) biosensor based on electroactive biofilms of activated sludge grown on the surface of a graphite-paste electrode modified with carbon nanotubes was studied. A complex of microscopic methods controlled biofilm formation: optical microscopy with phase contrast, scanning electron microscopy, and laser confocal microscopy. The features of charge transfer in the obtained electroactive biofilms were studied using the methods of cyclic voltammetry and electrochemical impedance spectroscopy. The rate constant of the interaction of microorganisms with the extracellular electron carrier (0.79 ± 0.03 dm3(g s)−1) and the heterogeneous rate constant of electron transfer (0.34 ± 0.02 cm s−1) were determined using the cyclic voltammetry method. These results revealed that the modification of the carbon nanotubes’ (CNT) electrode surface makes it possible to create electroactive biofilms. An analysis of the metrological and analytical characteristics of the created biosensors showed that the lower limit of the biosensor based on an electroactive biofilm of activated sludge is 0.41 mgO2/dm3, which makes it possible to analyze almost any water sample. Analysis of 12 surface water samples showed a high correlation (R2 = 0.99) with the results of the standard method for determining biochemical oxygen demand.
1

1 October 2016 in Enzyme and Microbial Technology
Verified
Journal Article
Closed access
OKOlga Kamanina
Olga Kamanina
DLDaria G. Lavrova
Daria G. Lavrova
Vyacheslav ArlyapovVyacheslav Arlyapov
Vyacheslav Arlyapov
VAValeriy A. Alferov
Valeriy A. Alferov
OPOlga N. Ponamoreva
Olga N. Ponamoreva