Giyeon Kim

Ms. Giyeon Kim

Yonsei University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GKGiyeon Kim
Giyeon Kim
SKSunjai Kim
Sunjai Kim
JCJaeseung Chang
Jaeseung Chang
SPSe-wook Pyo
Se-wook Pyo
Evaluating tooth mobility is clinically significant, not only for diagnosing periodontal tissues but also in determining the overall periodontal treatment plan. Numerous studies related to tooth mobility have been conducted over the years, including the proposal of various classifications as well as the development of electronic devices for objective measurement. However, there is still no consensus on the measurement methods and criteria for assessing tooth mobility. In this study, we provide a comprehensive review of past and current tooth mobility classification and measurement methods. In order to propose a new method to intuitively evaluate tooth mobility based on previous studies, a digital approach capable of recording tooth micromovements induced by dynamic load should be considered.

25 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GKGiyeon Kim
Giyeon Kim
JLJiayi Li
Jiayi Li
Hong Seok MoonHong Seok Moon
Hong Seok Moon
KOKyung Chul Oh
Kyung Chul Oh
The study aimed to evaluate the time-related accuracy of additively manufactured dental casts and to compare it with scan data obtained with an intraoral scanner in vitro. Twenty-eight markers were attached to a set of dentiforms as reference model, and the distances between the markers were measured using a digital caliper. An intraoral scanner was used to obtain the virtual scan data of the reference model with a total of 30 scans per arch. The distances between markers were measured using a three-dimensional inspection software for all scans (group IOS). Scan data were additively manufactured using a 3D printer, and the distances between markers were measured as in the reference model immediately after post-polymerization (group PPIA), 1 day (group PP1D), 7 days (group PP7D), and 30 days after post-polymerization (group PP30D). The linear deviation in group IOS was 199.74 ± 11.14 μm, PPIA was 242.88 ± 49 μm, PP1D was 259.9 ± 42.59 μm, PP7D was 289.82 ± 39.74 μm, and PP30D was 315.8 ± 33.28 μm, in comparison with the reference model, with significant differences among all groups (all p < 0.05). When additively manufacturing casts from scan data to verify the quality of dental prostheses designed virtually, the prostheses should be adapted to casts manufactured within one week.