Se-wook Pyo

Prof. Se-wook Pyo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SPSe-wook Pyo
Se-wook Pyo
Young-Jun LimYoung-Jun Lim
Young-Jun Lim
KKKi-Tae Koo
Ki-Tae Koo
JLJungwon Lee
Jungwon Lee
The purpose of this review is to examine various assessment methods in order to compare the accuracy between the virtually planned and clinically achieved implant positions. In this review, comparison methods using pre- and post-operative computed topography (CT) data and digital impressions for definitive prosthesis will be described. The method for the displacement and strain for quantification of the error will also be explored. The difference between the planned and the actual implant placement position in guided implant surgery is expressed as an error. Assessing the accuracy of implant-guided surgery can play an important role as positive feedback in order to reduce errors. All of the assessment methods have their own inevitable errors and require careful interpretation in evaluation.

1 January 2020 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
JLJungwon Lee
Jungwon Lee
SPSe-wook Pyo
Se-wook Pyo
HCHyun-Jae Cho
Hyun-Jae Cho
JAJung-Sub An
Jung-Sub An
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
YLYong-Moo Lee
Yong-Moo Lee
A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

27 December 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GKGiyeon Kim
Giyeon Kim
SKSunjai Kim
Sunjai Kim
JCJaeseung Chang
Jaeseung Chang
SPSe-wook Pyo
Se-wook Pyo
Evaluating tooth mobility is clinically significant, not only for diagnosing periodontal tissues but also in determining the overall periodontal treatment plan. Numerous studies related to tooth mobility have been conducted over the years, including the proposal of various classifications as well as the development of electronic devices for objective measurement. However, there is still no consensus on the measurement methods and criteria for assessing tooth mobility. In this study, we provide a comprehensive review of past and current tooth mobility classification and measurement methods. In order to propose a new method to intuitively evaluate tooth mobility based on previous studies, a digital approach capable of recording tooth micromovements induced by dynamic load should be considered.

22 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
SPSe-wook Pyo
Se-wook Pyo
DKDae-Joon Kim
Dae-Joon Kim
JHJung-Suk Han
Jung-Suk Han
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
Computer-aided design and manufacturing technology has been closely associated with implant-supported restoration. The digital system employed for prosthodontic restorations comprises data acquisition, processing, and manufacturing using subtractive or additive methods. As digital implantology has developed, optical scanning, computer-based digital algorithms, fabricating techniques, and numerical control skills have all rapidly improved in terms of their accuracy, which has resulted in the development of new ceramic materials with advanced esthetics and durability for clinical application. This study reviews the application of digital technology in implant-supported dental restoration and explores two globally utilized ceramic restorative materials: Yttria-stabilized tetragonal zirconia polycrystalline and lithium disilicate glass ceramics.

23 May 2023 in Journal of Dentistry
Verified
Journal Article
Closed access
SPSe-wook Pyo
Se-wook Pyo
KPKoungjin Park
Koungjin Park
RDRene Daher
Rene Daher
HKHo-Beom Kwon
Ho-Beom Kwon
JHJung-Suk Han
Jung-Suk Han
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee

1 January 2024 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
YCYoung Eun Cho
Young Eun Cho
SHSeoung-Jin Hong
Seoung-Jin Hong
JHJung-Bo Huh
Jung-Bo Huh
SPSe-wook Pyo
Se-wook Pyo
SYSoo-Yoen Yoo
Soo-Yoen Yoo
Kim SY, et al. J Adv Prosthodont. 2024 Aug;16(4):255-266. https://doi.org/10.4047/jap.2024.16.4.255