In this work, we develop a coreless rolled dielectric elastomer actuator (CORDEA) to be used as artificial muscles in soft robotic structures. The new CORDEA concept is based on a 50 µm silicone film with screen-printed electrodes made of carbon black suspended in polydimethylsiloxane. Two printed silicone films are stacked together and then tightly rolled in a spiral-like structure. Readily available off-the-shelf components are used to implement both electrical and mechanical contacts. A novel manufacturing process is developed to enable the production of rolled actuators without a hollow core, with a focus on simplicity and reliability. In this way, actuator systems with high energy density can be effectively achieved. After presenting the design, an experimental evaluation of the CORDEA electromechanical behavior is performed. Finally, actuator experiments in which the CORDEA is pre-loaded with a mass load and subsequently subject to cycling voltage are illustrated, and the resulting performance is discussed.
19 November 2021 in Smart Materials and Structures
Due to their large deformation, high energy density, and high compliance, dielectric elastomer actuators (DEAs) have found a number of applications in several areas of mechatronics and robotics. Among the many types of DEAs proposed in the literature, rolled DEAs (RDEAs) represent one of the most popular configurations. RDEAs can be effectively used as compact muscle-like actuators for soft robots, since they allow eliminating the need for external motors or compressors while providing at the same time a flexible and lightweight structure with self-sensing capabilities. To effectively design and control complex RDEA-driven systems and robots, accurate and numerically efficient mathematical models need to be developed. In this work, we propose a novel lumped-parameter model for silicone-based, thin and tightly rolled RDEAs. The model is grounded on a free-energy approach, and permits to describe the electro-mechanically coupled response of the transducer with a set of nonlinear ordinary differential equations. After deriving the constitutive relationships, the model is validated by means of an extensive experimental campaign, conducted on three RDEA specimens having different geometries. It is shown how the developed model permits to accurately predict the effects of several parameters (external load, applied voltage, actuator geometry) on the RDEA electro-mechanical response, while maintaining an overall simple mathematical structure.
Dielectric elastomer transducers (DETs), namely, highly stretchable dielectric membranes sandwiched between two compliant electrodes, allow to develop sensors, actuators, and generator systems. DET performance is strongly influenced by the material properties of dielectric and electrodes, as well as the type of manufacturing process. For instance, when manufacturing the electrodes via screen‐printing, significant amounts of solvents are needed to adjust the printing materials’ viscosity, but they potentially alter DET properties. The investigation of this effect, however, is largely unexplored. Addressing this issue, this article investigates the influence of various solvents on a DET consisting of a polydimethylsiloxane (PDMS) membrane with PDMS/carbon black electrodes. Physical and chemical interactions between dielectric and solvents are characterized by infrared‐spectroscopy (IR), optical investigations, and light microscopy. Different solvents used for screen‐printing are analyzed in terms of their effects on the electrode electrical resistance, screen‐print image, and breakdown strength. Even though the solvent strongly affects the electrodes’ electrical resistance (ranging from ≈22 kΩ to >MΩ), it does not modify the breakdown strength of the pure dielectric (113 V μm−1). In the IR, no chemical aging is found. The obtained results provide systematic guidelines for the choice of solvents in DET electrode manufacturing.
Thanks to their outstanding properties, in the last few years Dielectric Elastomer Actuators (DEAs) have increasingly attracted the interest of the scientific community and generated a surge in the effort devoted to their industrialization. Compared to conventional actuator systems, DEAs are based on inexpensive and widely available polymeric materials, which make them potentially attractive from a market perspective. However, DEA systems with a given layout and dimensions have a fixed force-stroke response that is only suitable for a specific load profile. This leads to a wide variety of designs combined with small production volumes and high costs, limiting the competitive advantage. This work addresses this issue by proposing a combination of DEA systems with compliant scissor linkage transmission mechanisms, which provide linear stroke and force scaling and simultaneously maintain performance optimization by leaving the convertible energy density of the DEA unaffected. For this purpose, three systems are designed, based on a same strip-shaped DEA combined with inclined buckled beam biasing mechanisms. Two of the systems are coupled with scissor linkages that offer transmission ratios of 3:1 and 1:3, respectively, to adapt the system to different load profiles. The system design is explained in detail, and the functional principle is validated through experiments.