Pater Oberta

Pater Oberta


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
MMMatthias Muntwiler
Matthias Muntwiler
JZJun Zhang
Jun Zhang
RSRoland Stania
Roland Stania
FMFumihiko Matsui
Fumihiko Matsui
POPater Oberta
Pater Oberta
TGThomas Greber
Thomas Greber
The Photo-Emission and Atomic Resolution Laboratory (PEARL) is a new soft X-ray beamline and surface science laboratory at the Swiss Light Source. PEARL is dedicated to the structural characterization of local bonding geometry at surfaces and interfaces of novel materials, in particular of molecular adsorbates, nanostructured surfaces, and surfaces of complex materials. The main experimental techniques are soft X-ray photoelectron spectroscopy, photoelectron diffraction, and scanning tunneling microscopy (STM). Photoelectron diffraction in angle-scanned mode measures bonding angles of atoms near the emitter atom, and thus allows the orientation of small molecules on a substrate to be determined. In energy scanned mode it measures the distance between the emitter and neighboring atoms; for example, between adsorbate and substrate. STM provides complementary, real-space information, and is particularly useful for comparing the sample quality with reference measurements. In this article, the key features and measured performance data of the beamline and the experimental station are presented. As scientific examples, the adsorbate–substrate distance in hexagonal boron nitride on Ni(111), surface quantum well states in a metal-organic network of dicyano-anthracene on Cu(111), and circular dichroism in the photoelectron diffraction of Cu(111) are discussed.

29 November 2018 in Optica
Verified
Journal Article
Closed access
PDF file
PVPablo Villanueva-Perez
Pablo Villanueva-Perez
BPB. Pedrini
B. Pedrini
RMR. Mokso
R. Mokso
PVP. Vagovic
P. Vagovic
VGV. A. Guzenko
V. A. Guzenko
MSM. Stampanoni
M. Stampanoni
High-brilliance x-ray sources (x-ray free-electron lasers or diffraction-limited storage rings) allow the visualization of ultrafast processes in a 2D manner using single exposures. Current 3D approaches scan the sample using multiple exposures, and hence they are not compatible with single-shot acquisitions. Here we propose and verify experimentally an x-ray multi-projection imaging approach, which uses a crystal to simultaneously acquire nine angularly resolved projections with a single x-ray exposure. When implemented at high-brilliance sources, this approach can provide volumetric information of natural processes and non-reproducible samples in the micrometer to nanometer resolution range, and resolve timescales from microseconds down to femtoseconds.

10 November 2012 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
PVPatrik Vagovič
Patrik Vagovič
DKDušan Korytár
Dušan Korytár
ACAngelica Cecilia
Angelica Cecilia
EHElias Hamann
Elias Hamann
LŠLibor Švéda
Libor Švéda
TBTilo Baumbach
Tilo Baumbach

13 April 2022 in Universe
Verified
Journal Article
Open access
PDF file
CGCarlos Granja
Carlos Granja
RHRene Hudec
Rene Hudec
VMVeronika Maršíková
Veronika Maršíková
AIAdolf Inneman
Adolf Inneman
LPLadislav Pína
Ladislav Pína
POPater Oberta
Pater Oberta
We present a miniaturized and wide field-of-view X-ray and Gamma-ray imager consisting of a segmented 2D optics-collimator coupled to the high-sensitivity semiconductor pixel detector Timepix equipped with a high-Z sensor (CdTe 2000 μm thick). The compact payload has been deployed in low-Earth orbit (LEO) onboard the 3U Cubesat VZLUSAT-2 which was launched on 13 January 2022. The instrument is designed to verify small spacecraft borne observation in open space of hard X-ray and Gamma-ray sources both of celestial and atmospheric origin. High-resolution spectral-sensitive X-ray and Gamma-ray images are provided with enhanced event discrimination and wide field-of-view up to 60°. Description of the instrument together with response evaluation and tests in ground with well-defined sources are presented. The intended observational plan for in-orbit measurements is outlined along with astrophysical goals and issues.

3 August 2012 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
POPater Oberta
Pater Oberta
YPY. Platonov
Y. Platonov
UFU. Flechsig
U. Flechsig

30 January 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
GLGoran Lovric
Goran Lovric
POPater Oberta
Pater Oberta
IMIstvan Mohacsi
Istvan Mohacsi
MSMarco Stampanoni
Marco Stampanoni
RMRajmund Mokso
Rajmund Mokso
A reliable measurement of beam coherence is important for optimal performance of a number of coherence methods being utilized at third-generation synchrotrons and free-electron lasers. Various approaches have been proposed in the past for determining the source size, and hence the degree of coherence; however they often require complex setups with perfect optics and suffer from undefined uncertainties. We present a robust tool for X-ray source characterization with a full quantitative uncertainty analysis for fast on-the-fly coherence measurements. The influence of three multilayer monochromator crystals on the apparent source size is evaluated using the proposed method.