11 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
WLWen-Chih Liu
Wen-Chih Liu
CCChih-Hau Chang
Chih-Hau Chang
Chung-Hwan ChenChung-Hwan Chen
Chung-Hwan Chen
CLChun-Kuan Lu
Chun-Kuan Lu
CMChun-Hsien Mark Ma
Chun-Hsien Mark Ma
YFYin-Chih Fu
Yin-Chih Fu
Suture anchors are extensively used in rotator cuff tear surgery. With the advancement of three-dimensional printing technology, biodegradable metal has been developed for orthopedic applications. This study adopted three-dimensional-printed biodegradable Fe suture anchors with double-helical threads and commercialized non-vented screw-type Ti suture anchors with a tapered tip in the experimental and control groups, respectively. The in vitro study showed that the Fe and Ti suture anchors exhibited a similar ultimate failure load in 20-pound-per-cubic-foot polyurethane foam blocks and rabbit bone. In static immersion tests, the corrosion rate of Fe suture anchors was 0.049 ± 0.002 mm/year. The in vivo study was performed on New Zealand white rabbits and SAs were employed to reattach the ruptured supraspinatus tendon. The in vivo ultimate failure load of the Fe suture anchors was superior to that of the Ti suture anchors at 6 weeks. Micro-computed tomography showed that the bone volume fraction and bone surface density in the Fe suture anchors group 2 and 6 weeks after surgery were superior, and the histology confirmed that the increased bone volume around the anchor was attributable to mineralized osteocytes. The three-dimensional-printed Fe suture anchors outperformed the currently used Ti suture anchors.

Verified
Journal Article
Open access
PDF file
CTChien-Cheng Tai
Chien-Cheng Tai
YHYu-Min Huang
Yu-Min Huang
CLChen-Kun Liaw
Chen-Kun Liaw
KYKuo-Yi Yang
Kuo-Yi Yang
CMChun-Hsien Mark Ma
Chun-Hsien Mark Ma
Chih-Yu ChenChih-Yu Chen
Chih-Yu Chen
This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable iron IS types—manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)—were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.

1 July 2025 in npj Materials Degradation
Verified
Journal Article
Open access
PDF file
WLWen-Chih Liu
Wen-Chih Liu
HCHao-Wei Chang
Hao-Wei Chang
SHShin-I Huang
Shin-I Huang
KYKuo-Yi Yang
Kuo-Yi Yang
PTPei-I Tsai
Pei-I Tsai
YFYin-Chih Fu
Yin-Chih Fu
This study assessed osteointegration and degradation of 3D-printed porous pure iron (Fe) versus titanium (Ti) interference screws in porcine anterior cruciate ligament (ACL) reconstruction over 12 months. Twelve pigs were assigned to Fe (experimental) or Ti (control) groups and euthanized at 3-, 6-, or 12-month post-surgery. Osteointegration was evaluated via micro-computed tomography, biomechanical tests measured ACL failure load, and histology examined bone and tissue integration. No significant differences in ACL failure load were noted between groups. Fe implants showed significantly greater bone volume fraction, bone surface density, and intersection-to-total surface area (P = 0.025, 0.047, 0.021). Minimal degradation of Fe implants was observed, with stable implant volumes and histological confirmation of osteoid attachment. Median ambulation time was shorter with Fe implants (5 weeks) than with Ti implants (11 weeks; P = 0.075). Findings demonstrate Fe implants’ biocompatibility and enhanced peri-implant osteogenesis, though improved degradation rates are needed.