Satoshi Kasai

Dr. Satoshi Kasai


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
AYAkifumi Yoshida
Akifumi Yoshida
CKChiharu Kai
Chiharu Kai
HFHitoshi Futamura
Hitoshi Futamura
KOKunihiko Oochi
Kunihiko Oochi
SKSatoshi Kondo
Satoshi Kondo
SKSatoshi Kasai
Satoshi Kasai
Introduction: Physical measurements of expiratory flow volume and speed can be obtained using spirometry. These measurements have been used for the diagnosis and risk assessment of chronic obstructive pulmonary disease and play a crucial role in delivering early care. However, spirometry is not performed frequently in routine clinical practice, thereby hindering the early detection of pulmonary function impairment. Chest radiographs (CXRs), though acquired frequently, are not used to measure pulmonary functional information. This study aimed to evaluate whether spirometry parameters can be estimated accurately from single frontal CXR without image findings using deep learning.Methods: Forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and FEV1/FVC as spirometry measurements as well as the corresponding chest radiographs of 11,837 participants were used in this study. The data were randomly allocated to the training, validation, and evaluation datasets at an 8:1:1 ratio. A deep learning network was pretrained using ImageNet. The input and output information were CXRs and spirometry test values, respectively. The training and evaluation of the deep learning network were performed separately for each parameter. The mean absolute error rate (MAPE) and Pearson’s correlation coefficient (r) were used as the evaluation indices.Results: The MAPEs between the spirometry measurements and AI estimates for FVC, FEV1 and FEV1/FVC were 7.59% (r = 0.910), 9.06% (r = 0.879) and 5.21% (r = 0.522), respectively. A strong positive correlation was observed between the measured and predicted indices of FVC and FEV1. The average accuracy of >90% was obtained in each estimation of spirometry indices. Bland–Altman analysis revealed good agreement between the estimated and measured values for FVC and FEV1.Discussion: Frontal CXRs contain information related to pulmonary function, and AI estimation performed using frontal CXRs without image findings could accurately estimate spirometry values. The network proposed for estimating pulmonary function in this study could serve as a recommendation for performing spirometry or as an alternative method, suggesting its utility.

28 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YHyuta hirono
yuta hirono
ISIkumi Sato
Ikumi Sato
CKChiharu Kai
Chiharu Kai
AYAkifumi Yoshida
Akifumi Yoshida
Naoki KodamaNaoki Kodama
Naoki Kodama
SKSatoshi Kasai
Satoshi Kasai
Cardiotocography (CTG) is widely used to assess fetal well-being. CTG is typically obtained using ultrasound and autocorrelation methods, which extract periodicity from the signal to calculate the heart rate. However, during labor, maternal vessel pulsations can be measured, resulting in the output of the maternal heart rate (MHR). Since the autocorrelation output is displayed as fetal heart rate (FHR), there is a risk that obstetricians may mistakenly evaluate the fetal condition based on MHR, potentially overlooking the necessity for medical intervention. This study proposes a method that utilizes Doppler ultrasound (DUS) signals and artificial intelligence (AI) to determine whether the heart rate obtained by autocorrelation is of fetal origin. We developed a system to simultaneously record DUS signals and CTG and obtained data from 425 cases. The midwife annotated the DUS signals by auditory differentiation, providing data for AI, which included 30,160 data points from the fetal heart and 2160 data points from the maternal vessel. Comparing the classification accuracy of the AI model and a simple mathematical method, the AI model achieved the best performance, with an area under the curve (AUC) of 0.98. Integrating this system into fetal monitoring could provide a new indicator for evaluating CTG quality.

11 April 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
STShingo Takahashi
Shingo Takahashi
NSNoriko Sakurai
Noriko Sakurai
SKSatoshi Kasai
Satoshi Kasai
Naoki KodamaNaoki Kodama
Naoki Kodama
Previous studies have reported a relationship between stress and brain activity, and stress has been quantitatively evaluated using near-infrared spectroscopy (NIRS). In the present study, we examined whether a relationship exists between salivary amylase levels and brain activity during the trail-making test (TMT) using mobile NIRS. This study aimed to assess stress levels by using mobile NIRS. Salivary amylase was measured with a salivary amylase monitor, and hemoglobin concentration was measured using Neu’s HOT-2000. Measurements were taken four times for each subject, and the values at each measurement were evaluated. Changes in the values at the first–second, second–third, and third–fourth measurements were also analyzed. Results showed that the value of the fluctuations has a higher correlation than the comparison of point values. These results suggest that the accuracy of stress assessment by NIRS can be improved by using variability and time-series data compared with stress assessment using NIRS at a single time point.

26 March 2025 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
AYAkifumi Yoshida
Akifumi Yoshida
YSYoichi Sato
Yoichi Sato
CKChiharu Kai
Chiharu Kai
YHYuta Hirono
Yuta Hirono
ISIkumi Sato
Ikumi Sato
SKSatoshi Kasai
Satoshi Kasai
Introduction: Osteoporosis increases the risk of fragility fractures, especially of the lumbar spine and femur. As fractures affect life expectancy, it is crucial to detect the early stages of osteoporosis. Dual X-ray absorptiometry (DXA) is the gold standard for bone mineral density (BMD) measurement and the diagnosis of osteoporosis; however, its low screening usage is problematic. The accurate estimation of BMD using chest radiographs (CXR) could expand screening opportunities. This study aimed to indicate the clinical utility of osteoporosis screening using deep-learning-based estimation of BMD using bidirectional CXRs.Methods: This study included 1,624 patients aged ≥ 20 years who underwent DXA and bidirectional (frontal and lateral) chest radiography at a medical facility. A dataset was created using BMD and bidirectional CXR images. Inception-ResNet-V2-based models were trained using three CXR input types (frontal, lateral, and bidirectional). We compared and evaluated the BMD estimation performances of the models with different input information.Results: In the comparison of models, the model with bidirectional CXR showed the highest accuracy. The correlation coefficients between the model estimates and DXA measurements were 0.766 and 0.683 for the lumbar spine and femoral BMD, respectively. Osteoporosis detection based on bidirectional CXR showed higher sensitivity and specificity than the models with single-view CXR input, especially for osteoporosis based on T-score ≤ –2.5, with 92.8% sensitivity at 50.0% specificity.Discussion: These results suggest that bidirectional CXR contributes to improved accuracy of BMD estimation and osteoporosis screening compared with single-view CXR. This study proposes a new approach for early detection of osteoporosis using a deep learning model with frontal and lateral CXR inputs. BMD estimation using bidirectional CXR showed improved detection performance for low bone mass and osteoporosis, and has the potential to be used as a clinical decision criterion. The proposed method shows potential for more appropriate screening decisions, suggesting its usefulness in clinical practice.

17 May 2023 in Cancers
Verified
Journal Article
Open access
PDF file
CKChiharu Kai
Chiharu Kai
SISachi Ishizuka
Sachi Ishizuka
TOTsunehiro Otsuka
Tsunehiro Otsuka
MNMiyako Nara
Miyako Nara
SKSatoshi Kondo
Satoshi Kondo
SKSatoshi Kasai
Satoshi Kasai
Recently, breast types were categorized into four types based on the Breast Imaging Reporting and Data System (BI-RADS) atlas, and evaluating them is vital in clinical practice. A Japanese guideline, called breast composition, was developed for the breast types based on BI-RADS. The guideline is characterized using a continuous value called the mammary gland content ratio calculated to determine the breast composition, therefore allowing a more objective and visual evaluation. Although a discriminative deep convolutional neural network (DCNN) has been developed conventionally to classify the breast composition, it could encounter two-step errors or more. Hence, we propose an alternative regression DCNN based on mammary gland content ratio. We used 1476 images, evaluated by an expert physician. Our regression DCNN contained four convolution layers and three fully connected layers. Consequently, we obtained a high correlation of 0.93 (p < 0.01). Furthermore, to scrutinize the effectiveness of the regression DCNN, we categorized breast composition using the estimated ratio obtained by the regression DCNN. The agreement rates are high at 84.8%, suggesting that the breast composition can be calculated using regression DCNN with high accuracy. Moreover, the occurrence of two-step errors or more is unlikely, and the proposed method can intuitively understand the estimated results.

23 January 2025 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
ISIkumi Sato
Ikumi Sato
YHYuta Hirono
Yuta Hirono
ESEiri Shima
Eiri Shima
HYHiroto Yamamoto
Hiroto Yamamoto
KYKousuke Yoshihara
Kousuke Yoshihara
SKSatoshi Kasai
Satoshi Kasai
Introduction: Cardiotocography (CTG) is used to monitor and evaluate fetal health by recording the fetal heart rate (FHR) and uterine contractions (UC) over time. Among these, the detection of late deceleration (LD), the early marker of fetal mild hypoxemia, is important, and the temporal relationship between FHR and UC is an essential factor in deciphering it. However, there is a problem with UC signals generally tending to have poor signal quality due to defects in installation or obesity in pregnant women. Since obstetricians evaluate potential LD signals only from the FHR signal when the UC signal quality is poor, we hypothesized that LD could be detected by capturing the morphological features of the FHR signal using Artificial Intelligence (AI). Therefore, this study compares models using FHR only (FHR-only model) and FHR with UC (FHR + UC model) constructed using a Convolutional Neural Network (CNN) to examine whether LD could be detected using only the FHR signal.Methods: The data used to construct the CNN model were obtained from the publicly available CTU-UHB database. We used 86 cases with LDs and 440 cases without LDs from the database, confirmed by expert obstetricians.Results: The results showed high accuracy with an area under the curve (AUC) of 0.896 for the FHR-only model and 0.928 for the FHR + UC model. Furthermore, in a validation using 23 cases in which obstetricians judged that the UC signals were poor and the FHR signal had an LD-like morphology, the FHR-only model achieved an AUC of 0.867.Conclusion: This indicates that using only the FHR signal as input to the CNN could detect LDs and potential LDs with high accuracy. These results are expected to improve fetal outcomes by promptly alerting obstetric healthcare providers to signs of nonreassuring fetal status, even when the UC signal quality is poor, and encouraging them to monitor closely and prepare for emergency delivery.