Akifumi Yoshida

Dr. Akifumi Yoshida

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2022 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
AYAkifumi Yoshida
Akifumi Yoshida
YKYohan Kondo
Yohan Kondo
NYNorihiko Yoshimura
Norihiko Yoshimura
TKTatsuya Kuramoto
Tatsuya Kuramoto
AHAkira Hasegawa
Akira Hasegawa
TKTsutomu Kanazawa
Tsutomu Kanazawa

6 March 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
AYAkifumi Yoshida
Akifumi Yoshida
CKChiharu Kai
Chiharu Kai
HFHitoshi Futamura
Hitoshi Futamura
KOKunihiko Oochi
Kunihiko Oochi
SKSatoshi Kondo
Satoshi Kondo
SKSatoshi Kasai
Satoshi Kasai
Introduction: Physical measurements of expiratory flow volume and speed can be obtained using spirometry. These measurements have been used for the diagnosis and risk assessment of chronic obstructive pulmonary disease and play a crucial role in delivering early care. However, spirometry is not performed frequently in routine clinical practice, thereby hindering the early detection of pulmonary function impairment. Chest radiographs (CXRs), though acquired frequently, are not used to measure pulmonary functional information. This study aimed to evaluate whether spirometry parameters can be estimated accurately from single frontal CXR without image findings using deep learning.Methods: Forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and FEV1/FVC as spirometry measurements as well as the corresponding chest radiographs of 11,837 participants were used in this study. The data were randomly allocated to the training, validation, and evaluation datasets at an 8:1:1 ratio. A deep learning network was pretrained using ImageNet. The input and output information were CXRs and spirometry test values, respectively. The training and evaluation of the deep learning network were performed separately for each parameter. The mean absolute error rate (MAPE) and Pearson’s correlation coefficient (r) were used as the evaluation indices.Results: The MAPEs between the spirometry measurements and AI estimates for FVC, FEV1 and FEV1/FVC were 7.59% (r = 0.910), 9.06% (r = 0.879) and 5.21% (r = 0.522), respectively. A strong positive correlation was observed between the measured and predicted indices of FVC and FEV1. The average accuracy of >90% was obtained in each estimation of spirometry indices. Bland–Altman analysis revealed good agreement between the estimated and measured values for FVC and FEV1.Discussion: Frontal CXRs contain information related to pulmonary function, and AI estimation performed using frontal CXRs without image findings could accurately estimate spirometry values. The network proposed for estimating pulmonary function in this study could serve as a recommendation for performing spirometry or as an alternative method, suggesting its utility.

28 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YHyuta hirono
yuta hirono
ISIkumi Sato
Ikumi Sato
CKChiharu Kai
Chiharu Kai
AYAkifumi Yoshida
Akifumi Yoshida
Naoki KodamaNaoki Kodama
Naoki Kodama
SKSatoshi Kasai
Satoshi Kasai
Cardiotocography (CTG) is widely used to assess fetal well-being. CTG is typically obtained using ultrasound and autocorrelation methods, which extract periodicity from the signal to calculate the heart rate. However, during labor, maternal vessel pulsations can be measured, resulting in the output of the maternal heart rate (MHR). Since the autocorrelation output is displayed as fetal heart rate (FHR), there is a risk that obstetricians may mistakenly evaluate the fetal condition based on MHR, potentially overlooking the necessity for medical intervention. This study proposes a method that utilizes Doppler ultrasound (DUS) signals and artificial intelligence (AI) to determine whether the heart rate obtained by autocorrelation is of fetal origin. We developed a system to simultaneously record DUS signals and CTG and obtained data from 425 cases. The midwife annotated the DUS signals by auditory differentiation, providing data for AI, which included 30,160 data points from the fetal heart and 2160 data points from the maternal vessel. Comparing the classification accuracy of the AI model and a simple mathematical method, the AI model achieved the best performance, with an area under the curve (AUC) of 0.98. Integrating this system into fetal monitoring could provide a new indicator for evaluating CTG quality.

29 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
CKChiharu Kai
Chiharu Kai
SKSatoshi Kondo
Satoshi Kondo
TOTsunehiro Otsuka
Tsunehiro Otsuka
AYAkifumi Yoshida
Akifumi Yoshida
ISIkumi Sato
Ikumi Sato
SKSatoshi Kasai
Satoshi Kasai
A comparative interpretation of mammograms has become increasingly important, and it is crucial to develop subtraction processing and registration methods for mammograms. However, nonrigid image registration has seldom been applied to subjects constructed with soft tissue only, such as mammograms. We examined whether subtraction processing for the comparative interpretation of mammograms can be performed using nonrigid image registration. As a preliminary study, we evaluated the results of subtraction processing by applying nonrigid image registration to normal mammograms, assuming a comparative interpretation between the left and right breasts. Mediolateral-oblique-view mammograms were taken from noncancer patients and divided into 1000 cases for training, 100 cases for validation, and 500 cases for testing. Nonrigid image registration was applied to align the horizontally flipped left-breast mammogram with the right one. We compared the sum of absolute differences (SAD) of the difference of bilateral images (Difference Image) with and without the application of nonrigid image registration. Statistically, the average SAD was significantly lower with the application of nonrigid image registration than without it (without: 0.0692; with: 0.0549 (p < 0.001)). In four subgroups using the breast area, breast density, compressed breast thickness, and Difference Image without nonrigid image registration, the average SAD of the Difference Image was also significantly lower with nonrigid image registration than without it (p < 0.001). Nonrigid image registration was found to be sufficiently useful in aligning bilateral mammograms, and it is expected to be an important tool in the development of a support system for the comparative interpretation of mammograms.

6 July 2026 in European Journal of Radiology Open
Verified
Journal Article
Open access
AYAkifumi Yoshida
Akifumi Yoshida
CKChiharu Kai
Chiharu Kai
ISIkumi Sato
Ikumi Sato
HFHitoshi Futamura
Hitoshi Futamura
KOKunihiko Oochi
Kunihiko Oochi
SKSatoshi Kasai
Satoshi Kasai
Although deep learning models using chest radiographs can estimate spirometry measurements, further investigation is needed to evaluate their ability to screen for preserved ratio impaired spirometry (PRISm), an important pre-COPD subtype. This study assessed whether a chest radiograph-based deep learning model can accurately detect PRISm and perform efficient opportunistic screening. This retrospective study included 54654 paired chest radiography and spirometry datasets from 38470 health checkup participants at a Japanese institution who underwent chest radiography and spirometry on the same day in 2018 and 2019. The dataset of 80% participants was used for model development, and the remaining 20% was used for performance evaluation. We developed a deep learning model that used frontal chest radiographs and demographic scalar inputs to detect PRISm and other pulmonary dysfunction subtypes, including FEV₁ decline, FVC decline, FVC and FEV₁ decline, and airflow limitation. Model performance was evaluated on the internal testing dataset. Subgroup analyses were performed across five independent factors: age, height, ppFVC, ppFEV₁, and FEV₁/FVC. The model achieved an AUROC of 0.892 (95% CI, 0.875–0.906), a sensitivity of 71.6%, and a specificity of 87.9% for PRISm detection on the testing dataset (N = 10917). No significant differences in AUROC were observed across subgroups defined by age, height, FEV₁/FVC, or ppFEV₁. The AUROC values for detecting all pulmonary dysfunction subtypes exceeded 0.8. The chest radiography-based model can effectively detect PRISm and may be useful for opportunistic screening of PRISm for supporting early risk management and intervention for pre-COPD conditions and obstructive pulmonary diseases.