Xiaoqing Zhou

Xiaoqing Zhou


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Energy and Buildings
Verified
Journal Article
Closed access
SCSihao Chen
Sihao Chen
XZXiaoqing Zhou
Xiaoqing Zhou
GZGuang Zhou
Guang Zhou
CFChengliang Fan
Chengliang Fan
PDPuxian Ding
Puxian Ding
QCQiliang Chen
Qiliang Chen

7 November 2022 in Energy and Buildings
Verified
Journal Article
Closed access
CFChengliang Fan
Chengliang Fan
XZXiaoqing Zhou
Xiaoqing Zhou

10 June 2023 in Energy and Buildings
Verified
Journal Article
Closed access
SCSihao Chen
Sihao Chen
PDPuxian Ding
Puxian Ding
GZGuang Zhou
Guang Zhou
XZXiaoqing Zhou
Xiaoqing Zhou
JLJing Li
Jing Li
JLJiangbo Li
Jiangbo Li

18 October 2018 in Materials
Verified
Journal Article
Open access
PDF file
TXTao Xu
Tao Xu
Jiayu ChenJiayu Chen
Jiayu Chen
WYWenhui Yuan
Wenhui Yuan
YLYinhua Liu
Yinhua Liu
Yongjun SunYongjun Sun
Yongjun Sun
XZXiaoqing Zhou
Xiaoqing Zhou
Among recent advances in electronic packaging technologies, electrically conductive adhesives (ECAs) attract most researchers’ attention, as they are environment-friendly and simple to apply. ECAs also have a lower operating temperature and volume resistivity compared with conventional electronic conductive adhesives. In ECAs, the conducting fillers play a significant role in improving conductivity and strength. In this work, as filler additives, the silver nanowires/graphene nanocomposites (AgNWs-GNs) were successfully fabricated via a facile self-assembly method. The characteristics of the as-prepared nanocomposites were evaluated by FTIR (Fourier Transform infrared spectroscopy), XRD (X-ray Diffraction), XPS (X-ray photoelectron spectroscopy), TEM (Transmission electron microscope) and Raman tests, demonstrating a successful synthesis process. Different amounts of AgNWs-GNs were used as additives in micron flake silver filler, and the effects of AgNWs-GNs on the properties of ECAs were studied. The results suggested that the as-synthesized composites can significantly improve the electrical conductivity and shear strength of ECAs. With 0.8% AgNWs/GNs (AgNWs to GO (Graphite oxide) mass ratio is 4:1), the ECAs have the lowest volume resistivity of 9.31 × 10−5 Ω·cm (95.4% lower than the blank sample without fillers), while with 0.6% AgNWs/GNs (AgNWs to GO mass ratio is 6:1), the ECAs reach the highest shear strength of 14.3 MPa (68.2% higher than the blank sample).

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
XXXiu Xiong
Xiu Xiong
LLLi Li
Li Li
XZXiaoqing Zhou
Xiaoqing Zhou

29 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LLli li
li li
JCJunfeng Cheng
Junfeng Cheng
ZLZhichao Liu
Zhichao Liu
QLQingliang Li
Qingliang Li
LYLan Yu
Lan Yu
YPYue Pang
Yue Pang
Architectural vertical green walls can mitigate the urban heat island effect, provide shade and cooling, reduce energy consumption, improve a microclimate, and increase indoor comfort. However, an excessive pursuit of high coverage may diminish the benefit ratio and adversely affect ventilation and lighting. Field measurements were conducted in the hot and humid Guangzhou area to investigate the thermal benefits of external vertical green walls with varying green coverage and diverse layouts, encompassing effects such as shading, insulation, cooling, and humidification. Analyses were conducted using ENVI-met, orthogonal experiments, and SPSS to quantify the moderating effects of planted green coverage (PGC), leaf area density (LAD), and air interstitial layers on the environmental thermal benefits. The results indicated that the cooling and humidifying effects of 100% PGC and 75% PGC were comparable and superior to those of 50% PGC, yet 75% PGC outperformed 100% PGC in terms of indoor humidification. Among the layout modes, the horizontal layout was the most effective for cooling and humidification, followed by the point layout, with the vertical layout being the least effective. A global sensitivity analysis revealed that PGC had the greatest impact on wall cooling and outdoor humidification, LAD significantly influenced humidification, the width of air interstitial layers had a minor impact, and the two architectural vertical greening design ratios of 75% PGC × 4.60 LAD and 75% PGC × 2.70 LAD were particularly effective for cooling and humidification. Incorporating horizontal or point-like layouts can enhance façade design diversity while preserving the desired environmental thermal benefits, thereby contributing to the overall aesthetics of a building.