28 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
JSJhen-Yang Syu
Jhen-Yang Syu
HCHsiao-Wei Chu
Hsiao-Wei Chu
YSYEN LING SUNG
YEN LING SUNG
LCLin Chou
Lin Chou
SLShien-Fong Lin
Shien-Fong Lin
Continuous blood pressure (BP) measurement is crucial for long-term cardiovascular monitoring, especially for prompt hypertension detection. However, most of the continuous BP measurements rely on the pulse transit time (PTT) from multiple-channel physiological acquisition systems that impede wearable applications. Recently, wearable and smart health electronics have become significant for next-generation personalized healthcare progress. This study proposes an intelligent single-channel bio-impedance system for personalized BP monitoring. Compared to the PTT-based methods, the proposed sensing configuration greatly reduces the hardware complexity, which is beneficial for wearable applications. Most of all, the proposed system can extract the significant BP features hidden from the measured bio-impedance signals by an ultra-lightweight AI algorithm, implemented to further establish a tailored BP model for personalized healthcare. In the human trial, the proposed system demonstrates the BP accuracy in terms of the mean error (ME) and the mean absolute error (MAE) within 1.7 ± 3.4 mmHg and 2.7 ± 2.6 mmHg, respectively, which agrees with the criteria of the Association for the Advancement of Medical Instrumentation (AAMI). In conclusion, this work presents a proof-of-concept for an AI-based single-channel bio-impedance BP system. The new wearable smart system is expected to accelerate the artificial intelligence of things (AIoT) technology for personalized BP healthcare in the future.

15 September 2020 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
TLTing-Tse Lin
Ting-Tse Lin
YSYEN LING SUNG
YEN LING SUNG
JSJhen‐Yang Syu
Jhen‐Yang Syu
KLKia‐Yuan Lin
Kia‐Yuan Lin
HHHung‐Jui Hsu
Hung‐Jui Hsu
SLShien-Fong Lin
Shien-Fong Lin
Background: Patients with rheumatoid arthritis are at twice the risk of ventricular arrhythmia and sudden cardiac death as the general population. We hypothesize that β‐blocker treatment of rheumatoid arthritis is antiarrhythmic by producing synergistic anticatecholaminergic and anti‐inflammatory effects. Methods and Results: Collagen‐induced arthritis (CIA) was induced in Lewis rats by immunization with type II collagen in Freund's incomplete adjuvant. The treatment with propranolol (4 mg/kg) started on the first day of immunization. We evaluated the ventricular vulnerability to ventricular arrhythmia using in vivo programmed stimulation and performed ex vivo optical mapping to measure the electrical remodeling of the heart. The ventricular tissue was further processed for immunohistochemical staining and protein array analysis. The assessment of ventricular vulnerability showed that the number and duration of the induced ventricular arrhythmia episodes were increased in CIA rats, which were improved with propranolol treatment. The sympathovagal index and the plasma level of catecholamines significantly increased in CIA rats, whereas the use of propranolol attenuated sympathetic hyperactivity. In the optical mapping study, electrical remodeling, characterized by prolonged action potential duration, slow conduction velocity, and steepened action‐potential duration restitution, were noted in CIA rats and reversed in the propranolol‐treatment group. The propranolol treatment was associated with decreases in paw thickness, fewer inflammatory cell infiltrations in the heart, reduced levels of cardiac inflammatory cytokines, and less cardiac fibrosis as compared with the CIA group. Conclusions: CIA increased ventricular arrhythmia vulnerability through sympathetic hyperinnervation and proarrhythmic ventricular electrophysiological remodeling. Treatment with propranolol in CIA rats was both anti‐inflammatory and antiarrhythmic.

13 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHDong-Yu Hsu
Dong-Yu Hsu
YSYEN LING SUNG
YEN LING SUNG
SNShih-Hua Ni
Shih-Hua Ni
CHChiu-Yun Huang
Chiu-Yun Huang
YHYu-Xiang Huang
Yu-Xiang Huang
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Continuous monitoring of heart rate (HR) and respiratory rate (RR) plays a pivotal role in evaluating cardiopulmonary coordination. Wearable technologies have empowered long-term monitoring of cardiopulmonary parameters across a spectrum of activities, including physical exercise, mental states, dietary habits, and the effects of pharmaceutical interventions. This study presents a wearable pocket-sized cardiopulmonary sensor based on biomedical eddy current sensing technology. The novel sensor utilizes the magnetic coupling between ac coil-produced magnetic fields and cardiopulmonary eddy current-induced counteracting magnetic fields to measure resonant frequency variation in response to synchronized cardiac and lung activities without skin contact. The proposed pocket-sized sensor is characterized by its compact form with a diameter of 4.53 cm and supporting wireless data transmission. Importantly, the influence of resonant frequencies on cardiopulmonary signals was investigated through capacitor adjustments, resulting in personalized optimization of measurement conditions. In practical applications, the effect of wide fabric thicknesses on measurement performance was assessed, demonstrating identifiable signals for allowing the determination of HR and RR. In real-life scenarios, HR and RR were measured during both resting and physical exercise conditions, effectively showcasing the potential of a single compact sensor to capture essential cardiorespiratory coordination (CRC) indicators. These findings provide strong validation for the novel sensor’s promising potential in the realm of wearable, long-term, all-in-one cardiopulmonary healthcare.

25 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
HCHsiao-Wei Chu
Hsiao-Wei Chu
LCLin Chou
Lin Chou
YSYEN LING SUNG
YEN LING SUNG
YSYuan-Ta Shih
Yuan-Ta Shih
SLShien-Fong Lin
Shien-Fong Lin
Continuous hemodynamic monitoring is important for long-term cardiovascular healthcare, especially in hypertension. The impedance plethysmography (IPG) based carotid pulse sensing is a non-invasive diagnosis technique for measuring pulse signals and further evaluating the arterial conditions of the patient such as continuous blood pressure (BP) monitoring. To reach the high-resolution IPG-based carotid pulse detection for cardiovascular applications, this study provides an optimized measurement parameter in response to obvious pulsation from the carotid artery. The influence of the frequency of excitation current, electrode cross-sectional area, electrode arrangements, and physiological site of carotid arteries on IPG measurement resolution was thoroughly investigated for optimized parameters. In this study, the IPG system was implemented and installed on the subject’s neck above the carotid artery to evaluate the measurement parameters. The measurement results within 6 subjects obtained the arterial impedance variation of 2137 mΩ using the optimized measurement conditions, including excitation frequency of 50 kHz, a smaller area of 2 cm2, electrode spacing of 4 cm and 1.7 cm for excitation and sensing functions, and location on the left side of the neck. The significance of this study demonstrates an optimized measurement methodology of IPG-based carotid pulse sensing that greatly improves the measurement quality in cardiovascular monitoring.

24 September 2020 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
YSYEN LING SUNG
YEN LING SUNG
TLTing-Tse Lin
Ting-Tse Lin
JSJhen-Yang Syu
Jhen-Yang Syu
HHHung-Jui Hsu
Hung-Jui Hsu
KLKai-Yuan Lin
Kai-Yuan Lin
SLShien-Fong Lin
Shien-Fong Lin
Aims Hypertension is a significant risk for the development of left ventricular hypertrophy, diastolic dysfunction, followed by heart failure and sudden cardiac death. While therapy with sacubitril/valsartan (SV) reduces the risk of sudden cardiac death in patients with heart failure and systolic dysfunction, the effect on those with diastolic dysfunction remains unclear. We hypothesized that, in the animal model of hypertensive heart disease, treatment with SV reduces the susceptibility to ventricular arrhythmia. Methods and results Young adult female spontaneous hypertensive rats (SHRs) were randomly separated into three groups, which were SHRs, SHRs treated with valsartan, and SHRs treated with SV. In addition, the age‐matched and weight‐matched Wistar Kyoto rats were considered as controls, and there were 12 rats in each group. In vivo ventricular tachyarrhythmia induction and in vitro optical mapping were used to measure the inducibility of ventricular arrhythmias and to characterize the dynamic properties of electrical propagation. The level of small‐conductance Ca2+‐activated potassium channel type 2 (KCNN2) was analysed in cardiac tissue. Compared with SHR with left ventricular hypertrophy, treatment with SV significantly improved cardiac geometry (relative wall thickness, 0.68 ± 0.11 vs. 0.76 ± 0.13, P < 0.05) and diastolic dysfunction (isovolumetric relaxation time, 59.4 ± 3.2 vs. 70.5 ± 4.2 ms, P < 0.05; deceleration time of mitral E wave, 46 ± 4.8 vs. 42 ± 3.8, P < 0.05). The incidence of induced ventricular arrhythmia was significantly reduced in SHR treated with SV compared with SHR (ventricular tachycardia, 1.14 ± 0.32 vs. 2.91 ± 0.5 episodes per 10 stimuli, P < 0.001; ventricular fibrillation, 1.72 ± 0.31 vs. 5.81 ± 0.42 episodes per 10 stimuli, P < 0.001). The prolonged action potential duration (APD) and increase of the maximum slope of APD restitution were observed in SHR, while the treatment of SV improved the arrhythmogeneity (APD, 37.12 ± 6.18 vs. 92.41 ± 10.71 ms at 250 ms pacing cycle length, P < 0.001; max slope 0.29 ± 0.01 vs. 1.48 ± 0.04, P < 0.001). These effects were strongly associated with down‐regulation of KCNN2 (0.38 ± 0.07 vs. 0.74 ± 0.12 ng/ml, P < 0.001). The treatment of SV also decreased the level of N‐terminal pro‐B‐type natriuretic peptide, cardiac bridging integrator‐1, and intramyocardial fibrosis of SHR. Conclusions In conclusion, synergistic blockade of the neprilysin and the renin–angiotensin system by SV in SHRs results in KCNN2‐associated electrical remodelling in ventricle, which stabilizes electrical dynamics and attenuates arrhythmogenesis.

25 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHDong-Yu Hsu
Dong-Yu Hsu
YSYEN LING SUNG
YEN LING SUNG
ELEn-Zhu Lyu
En-Zhu Lyu
CHChiu-Yun Huang
Chiu-Yun Huang
YHYu-Xiang Huang
Yu-Xiang Huang
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Recent advancements in flexible patches offer stretchability and adaptability to body contours. However, most require skin contact, causing potential discomfort for long-term health monitoring. We present a non-contact electromagnetic induction-based patch sensor that integrates a passive LC tank, inductance-to-digital converter ASIC, and wireless module into a flexible substrate, characterizing compact of 9 cm × 5 cm and lightweight of 6 g. The proposed patch sensor employs biomedical eddy current sensing to establish magnetic coupling between the sensor coil's magnetic field and the counteracting magnetic fields generated by the biomedical target's eddy currents. This enables the measurement of resonance frequency variations in response to pulsatile signals across multiple physiological sites, including the heart, lungs, carotid, radial, and femoral arteries, without direct skin contact. The sensor demonstrates high applicability across various fabric materials and thicknesses, effectively detecting heart rate (HR) through fabric layers up to 5.35 mm thick when positioned at the chest. The accuracy of HR and respiratory rate (RR) measurements across all tested physiological sites achieved mean absolute errors (MAE) within ± 5 beats per minute (bpm) and ± 3 respirations per minute (rpm), respectively. Furthermore, the sensor can effectively respond to real-time physiological state changes, as demonstrated by cold pressor test-induced HR variations and different breathing modes, highlighting its practicality in real-life scenarios. In conclusion, the proposed patch sensor provides an all-in-one flexible, non-contact solution capable of multi-site physiological monitoring, offering high accuracy, comfort, and adaptability for wearable health monitoring.