Chiu-Yun Huang

Chiu-Yun Huang

Auto-generated profile, based on publicly available information

Chiu-Yun Huang

Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHDong-Yu Hsu
Dong-Yu Hsu
YSYEN LING SUNG
YEN LING SUNG
SNShih-Hua Ni
Shih-Hua Ni
CHChiu-Yun Huang
Chiu-Yun Huang
YHYu-Xiang Huang
Yu-Xiang Huang
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Continuous monitoring of heart rate (HR) and respiratory rate (RR) plays a pivotal role in evaluating cardiopulmonary coordination. Wearable technologies have empowered long-term monitoring of cardiopulmonary parameters across a spectrum of activities, including physical exercise, mental states, dietary habits, and the effects of pharmaceutical interventions. This study presents a wearable pocket-sized cardiopulmonary sensor based on biomedical eddy current sensing technology. The novel sensor utilizes the magnetic coupling between ac coil-produced magnetic fields and cardiopulmonary eddy current-induced counteracting magnetic fields to measure resonant frequency variation in response to synchronized cardiac and lung activities without skin contact. The proposed pocket-sized sensor is characterized by its compact form with a diameter of 4.53 cm and supporting wireless data transmission. Importantly, the influence of resonant frequencies on cardiopulmonary signals was investigated through capacitor adjustments, resulting in personalized optimization of measurement conditions. In practical applications, the effect of wide fabric thicknesses on measurement performance was assessed, demonstrating identifiable signals for allowing the determination of HR and RR. In real-life scenarios, HR and RR were measured during both resting and physical exercise conditions, effectively showcasing the potential of a single compact sensor to capture essential cardiorespiratory coordination (CRC) indicators. These findings provide strong validation for the novel sensor’s promising potential in the realm of wearable, long-term, all-in-one cardiopulmonary healthcare.

25 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHDong-Yu Hsu
Dong-Yu Hsu
YSYEN LING SUNG
YEN LING SUNG
ELEn-Zhu Lyu
En-Zhu Lyu
CHChiu-Yun Huang
Chiu-Yun Huang
YHYu-Xiang Huang
Yu-Xiang Huang
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Recent advancements in flexible patches offer stretchability and adaptability to body contours. However, most require skin contact, causing potential discomfort for long-term health monitoring. We present a non-contact electromagnetic induction-based patch sensor that integrates a passive LC tank, inductance-to-digital converter ASIC, and wireless module into a flexible substrate, characterizing compact of 9 cm × 5 cm and lightweight of 6 g. The proposed patch sensor employs biomedical eddy current sensing to establish magnetic coupling between the sensor coil's magnetic field and the counteracting magnetic fields generated by the biomedical target's eddy currents. This enables the measurement of resonance frequency variations in response to pulsatile signals across multiple physiological sites, including the heart, lungs, carotid, radial, and femoral arteries, without direct skin contact. The sensor demonstrates high applicability across various fabric materials and thicknesses, effectively detecting heart rate (HR) through fabric layers up to 5.35 mm thick when positioned at the chest. The accuracy of HR and respiratory rate (RR) measurements across all tested physiological sites achieved mean absolute errors (MAE) within ± 5 beats per minute (bpm) and ± 3 respirations per minute (rpm), respectively. Furthermore, the sensor can effectively respond to real-time physiological state changes, as demonstrated by cold pressor test-induced HR variations and different breathing modes, highlighting its practicality in real-life scenarios. In conclusion, the proposed patch sensor provides an all-in-one flexible, non-contact solution capable of multi-site physiological monitoring, offering high accuracy, comfort, and adaptability for wearable health monitoring.

28 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SNShih-Hua Ni
Shih-Hua Ni
YSYEN LING SUNG
YEN LING SUNG
DHDong-Yu Hsu
Dong-Yu Hsu
CHChiu-Yun Huang
Chiu-Yun Huang
DLDing-Nan Lai
Ding-Nan Lai
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Continuous cuffless blood pressure (BP) sensors are evolving for long-term cardiovascular monitoring, especially in diagnostic and prognostic stages. The existing techniques rely on photoplethysmography (PPG) and bio-impedance that have limitations, such as sensitivity to skin tone and high skin-electrode contact impedance that would degrade physiological signals measurement. To this end, this study presents a novel wearable coil-based ring-type sensor utilizing the novel biomedical eddy current technique for continuous BP measurement. The LC-based ring sensor generates the AC magnetic fields along with the finger in parallel with the digital arteries, detecting the resonant frequency variations in response to real-time vessel pulsations. The proposed ring-type sensor is characterized by its compact form with a diameter of 2.42 cm and supporting wireless data transmission. To optimize personalized sensing, the various resonant frequencies on vessel pulse measurements were investigated by human trials. The novel ring sensor is employed for the estimation of BP, demonstrating high Pearson’s correlations (systolic BP (SBP): 0.88, diastolic BP (DBP): 0.80) and low mean absolute error (MAE) within 10 subjects (SBP: 3.64 ± 2.71 mmHg, DBP: 3.20 ± 2.66 mmHg), revealing the significant potential use of biomedical eddy current-based ring sensor for continuous, accurate, and comprehensive cardiovascular monitoring.

20 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CHChiu-Yun Huang
Chiu-Yun Huang
YSYEN LING SUNG
YEN LING SUNG
SNShih-Hua Ni
Shih-Hua Ni
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Smartwatches commonly employ photoplethysmography (PPG) sensors for pulse measurement and health index computation, including heart rate (HR) and blood pressure (BP). However, PPG’s susceptibility to skin tone variations presents challenges to accuracy. This study presents a biomedical eddy current sensor (BECS)-based wristwatch that integrates a passive LC tank, inductance-to-digital converter ASIC, and wireless module fully embedded into the case back of the wristwatch. The BECS technology relies on magnetic coupling between the magnetic fields generated by the LC coil and the counteracting magnetic fields induced by the wrist artery, enabling the measurement of resonant frequency variations in response to arterial pulse signals. To enhance pulse measurement sensitivity, the optimal operating resonant frequency was determined by implementing a capacitor array and measuring pulse signals by human measurement to derive personalized design parameters. The proposed BECS-based wristwatch demonstrates pulse signal measurement insensitivity to skin tone compared to PPG-based modalities, as validated among subjects with different Fitzpatrick skin types. Importantly, the personalized BP algorithm was implemented based on HR and modified normalized pulse volume (mNPV), both derived from the measured pulse signals. The BP performance demonstrates the low mean absolute errors (MAEs) of $3.18~\pm ~2.61$ mmHg for systolic BP (SBP) and $3.64~\pm ~2.57$ mmHg for diastolic BP (DBP) among ten subjects, meeting the Association for the Advancement of Medical Instrumentation (AAMI) standard below $5~\pm ~8$ mmHg. The generalization of each personalized BP model was further verified through train-test split validation, with all results remaining within AAMI criteria. In conclusion, this study introduces a novel BECS-based wristwatch, highlighting its skin-tone friendliness and accurate BP monitoring, offering a promising alternative to optical modalities, thereby driving future smartwatch innovations.

24 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DHDong-Yu Hsu
Dong-Yu Hsu
YSYEN LING SUNG
YEN LING SUNG
CHChiu-Yun Huang
Chiu-Yun Huang
ELEn-Zhu Lyu
En-Zhu Lyu
CCChen-Chia Chang
Chen-Chia Chang
Ting-Wei WangTing-Wei Wang
Ting-Wei Wang
Non-contact electrocardiogram (ECG) sensors have been widely explored as unobtrusive, long-term solutions for detecting atrial fibrillation (AF). Recent clinical studies have demonstrated that abnormal activation of the autonomic nervous system plays a crucial role in the pathogenesis of AF, highlighting the importance of coordination between autonomic activity and cardiac electrophysiology, which shifts most standalone ECG-based AF detection towards AF prediction. In this study, we present a flexible electronic sensor with a bandwidth of 0.05 Hz to 1000 Hz, utilizing capacitive coupling to enable non-contact simultaneous measurement of capacitive skin sympathetic nerve activity (cSKNA) and capacitive ECG (cECG) signals. The flexible design ensures effective signal capture by conforming to body curvature, enhancing capacitive coupling. Human measurements involving cold pressor tests (CPT) were conducted to validate the cSKNA and cECG functionality and applicability of the proposed sensor under various fabric conditions, including different humidity levels, thicknesses, and materials. Moreover, human trials demonstrated the sensor’s capability to simultaneously capture cSKNA and cECG signals, effectively revealing neuro-cardiac interactions in real-time. Notably, during CPT-induced sympathetic nerve activation interventions, increases in measured cSKNA that exceeded the sympathetic burst threshold were associated with heart rate (HR) acceleration derived from the measured cECG signals, effectively demonstrating the sensor’s capability in capturing neuro-cardiac responses. In conclusion, the proposed sensor offers a non-contact unobtrusive sensing solution for monitoring neuro-cardiac interactions, providing new insights for establishing predictive AF models through a more convenient and comfortable sensing system without electrode preparation. Its ease of use and versatility make the sensor suitable for potential applications in wearable chest bands and smart beds in the future.