Rongbiao Wang

Dr. Rongbiao Wang

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JTJian Tang
Jian Tang
RWRongbiao Wang
Rongbiao Wang
BLBocheng Liu
Bocheng Liu
YKYihua Kang
Yihua Kang

13 October 2024 in NDT & E International
Verified
Journal Article
Closed access
RWRongbiao Wang
Rongbiao Wang
YCYongzhi Chen
Yongzhi Chen
HYHaozhi Yu
Haozhi Yu
Zhiyuan XuZhiyuan Xu
Zhiyuan Xu
JTJian Tang
Jian Tang
KSKai Song
Kai Song

9 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JTJian Tang
Jian Tang
RWRongbiao Wang
Rongbiao Wang
GQGongzhe Qiu
Gongzhe Qiu
YHYu Hu
Yu Hu
YKYihua Kang
Yihua Kang
Magnetic flux leakage (MFL) testing is widely used in non-destructive testing of ferromagnetic components. In view of the serious attenuation of the leakage magnetic field (LMF) caused by the transmission of LMF in the lift-off layer between the measuring point and the workpiece, this paper introduces an MFL detection method based on the slotted ferromagnetic lift-off layer (SFLL). The conventional non-ferromagnetic lift-off layer is changed to a ferromagnetic lift-off layer with a rectangular slot. The magnetic sensor is fixed above the slot and scans the workpiece together with the lift-off layer. First, the detection mechanism of the new method was studied by an equivalent LMF coil model. The permeability perturbation effect and the magnetization enhancement effect were analyzed in the new method. Based on the detection mechanism, the lift-off tolerance of the new method was investigated. Then, the LMF enhancement and lift-off tolerance of the new method in the steel plate detection model were studied. Finally, experiments were conducted to compare the new method with the conventional method. The simulation and experimental results show that the slotted ferromagnetic lift-off layer enhances the amplitude of the MFL signal and is tolerant to the lift-off value. This method provides a new idea for optimizing the design of the MFL sensor and improving the sensitivity of MFL detection at a large lift-off value.

18 May 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
RWRongbiao Wang
Rongbiao Wang
HYHaozhi Yu
Haozhi Yu
JTJian Tang
Jian Tang
BFBo Feng
Bo Feng
YKYihua Kang
Yihua Kang
KSKai Song
Kai Song
Thick-walled steel pipes, which bear high internal pressure, are widely applied in nuclear power and pressure pipelines. If there are defects in the inner wall, they are easy to expand and cause accidents. Therefore, the thick-walled steel pipe must be subject to non-destructive testing after production. For the magnetic flux leakage (MFL) testing method, the detection sensitivity gradually decreases with the increase of wall thickness. To solve this problem, a new structure of MFL probe is proposed in this paper. The influence of the iron core permeability on the MFL signal is analyzed theoretically, and the effect of the core length and diameter on the MFL signal is analyzed by simulation. The variation of the MFL signal with the change of the iron core and coil lift-off is studied respectively. The simulation results are verified by experiments. It is found that the lift-off of the iron-cored coil is determined by the iron core position. Based on this phenomenon, an MFL array probe is designed, which can be used for online detection of thick-walled steel pipes to improve the detection sensitivity of inner wall defects.

4 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKai Song
Kai Song
WWWentao Wang
Wentao Wang
BBBoxuan Bao
Boxuan Bao
WXWenyu Xie
Wenyu Xie
JYJinxiong Yu
Jinxiong Yu
RWRongbiao Wang
Rongbiao Wang
Hi-lock bolt fasteners are widely used in aircraft multi-layer structures, and it is especially important to detect hole edge defects of hi-lock bolt connection structures. In this study, an array remote field eddy current testing system based on FPGA(Field Programmable Gate Array) and an array remote field eddy current testing probe based on multiplexing the principle were designed and developed. Using this system, experiments were carried out on fastener test blocks, and the effects of defect length and buried depth on the detection signal were studied. The experimental results show that the defect length has a significant impact on the amplitude of the detection signal, but a small impact on the phase of the detection signal. The buried depth of a defect has a significant impact on the amplitude and phase of the defect signal. The attenuation law of the detection signal in the weak magnetic field region between channels was studied, and a rotation angle-w model was proposed. The model was used to locate the defect, and the detection signal when the defect was located directly below the coil was deduced. A method for defect evaluation using the phase and amplitude of the defect signal was proposed. It was verified that the defect location error was within 2°, and the positioning error was small, which provided a reference for the defect evaluation of array remote field eddy current.

18 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RWRongbiao Wang
Rongbiao Wang
YCYongzhi Chen
Yongzhi Chen
XXXiangdong Xu
Xiangdong Xu
SGShuanglin Guo
Shuanglin Guo
ZXZhiyuan Xu
Zhiyuan Xu
KSKai Song
Kai Song
Magnetic flux leakage testing methods have been extensively used to detect defects in ferromagnetic materials. However, variations in the thickness of the surface paint layers or wax deposition can lead to unknown lift-off, which results in significant depth quantification errors. To address the challenge of quantifying the depths of internal or external defects under unknown lift-off conditions, this study introduces a new evaluation method based on time-domain features. Theoretical analysis combining the magnetic field phase reversal phenomenon and the magnetic shielding effect reveals why the rising time of the internal defect signals remains unaffected by lift-off. The simulation results verified the insensitivity of the time features to lift-off. In this experiment, a cross-correlation algorithm was used to align different datasets. Wavelet analysis was employed to extract the rising time points, and a linear regression algorithm was applied to establish a depth quantification model under varying lift-off conditions. Finally, the validation of the pipeline samples demonstrated that the depth quantification error for defects under unknown lift-off conditions did not exceed 13%.