Tsukasa Watanabe

Dr. Tsukasa Watanabe


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
TWTsukasa Watanabe
Tsukasa Watanabe
HFHiroyuki Fujimoto
Hiroyuki Fujimoto
TMTadashi Masuda
Tadashi Masuda
A bilateral comparison of optical glass refractive index between NMIJ and INRiM for the validation of the measuring systems A Hirai, Y Hori, K Minoshima et al.

16 April 2014 in Measurement Science and Technology
Verified
Journal Article
Closed access
TWTsukasa Watanabe
Tsukasa Watanabe
MKMasahito Kon
Masahito Kon
NNNobuo Nabeshima
Nobuo Nabeshima
KTKayoko Taniguchi
Kayoko Taniguchi

21 November 2003
Verified
Conference Paper
Closed access
PDF file
TWTsukasa Watanabe
Tsukasa Watanabe
HFHiroyuki Fujimoto
Hiroyuki Fujimoto
KNKan Nakayama
Kan Nakayama
TMTadashi Masuda
Tadashi Masuda
MKMakoto Kajitani
Makoto Kajitani
This paper describes the automatic calibration system for an angle encode which is installed at the AIST (National Institute of Advanced Industrial Science and Technology). The system uses the Equal-Division-Averaged (EDA) method that is one kind of the self-checking method. This system has great performance of the calibration with small uncertainty. In this paper we try to explain the factor of uncertainty of this system. The dominant uncertainty factor is the eccentricity of shaft between the system and an external rotary encoder. The influence from other factors is very small about 0.01" or less.

22 October 2001
Verified
Conference Paper
Closed access
PDF file
TWTsukasa Watanabe
Tsukasa Watanabe
HFHiroyuki Fujimoto
Hiroyuki Fujimoto
KNKan Nakayama
Kan Nakayama
TMTadashi Masuda
Tadashi Masuda
MKMakoto Kajitani
Makoto Kajitani
This paper describes the automatic calibration system for angle encoders which is installed at the AIST. The system uses the Equal-Division-Averaged (EDA) method that is one kind of the self-checking method. Both of the reference standard and the object angle encoders are calibrated at the same time against all encoders graduations within only one hour. The resolution and an uncertainty are 0.001 inch and approximately +/- 0.05 inch, respectively. This equal- division-averaged method is hoped to become the national standard method for the calibration of angle encoders.

1 March 2016 in Measurement
Verified
Journal Article
Closed access
WKWataru Kokuyama
Wataru Kokuyama
TWTsukasa Watanabe
Tsukasa Watanabe
HNHideaki Nozato
Hideaki Nozato
AOAkihiro Ota
Akihiro Ota

9 May 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
TYTanfer Yandayan
Tanfer Yandayan
RGRalf D Geckeler
Ralf D Geckeler
AJAndreas Just
Andreas Just
MKMichael Krause
Michael Krause
SAS Asli Akgoz
S Asli Akgoz
TWTsukasa Watanabe
Tsukasa Watanabe
Interpolation errors at small angular scales are caused by the subdivision of the angular interval between adjacent grating lines into smaller intervals when radial gratings are used in angle encoders. They are often a major error source in precision angle metrology and better approaches for determining them at low levels of uncertainty are needed. Extensive investigations of interpolation errors of different angle encoders with various interpolators and interpolation schemes were carried out by adapting the shearing method to the calibration of autocollimators with angle encoders. The results of the laboratories with advanced angle metrology capabilities are presented which were acquired by the use of four different high precision angle encoders/interpolators/rotary tables. State of the art uncertainties down to 1 milliarcsec (5 nrad) were achieved for the determination of the interpolation errors using the shearing method which provides simultaneous access to the angle deviations of the autocollimator and of the angle encoder. Compared to the calibration and measurement capabilities (CMC) of the participants for autocollimators, the use of the shearing technique represents a substantial improvement in the uncertainty by a factor of up to 5 in addition to the precise determination of interpolation errors or their residuals (when compensated). A discussion of the results is carried out in conjunction with the equipment used.