National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology Ibaraki, Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-0035, Tsukuba, Ibaraki, 305-8568, JAPAN
Auto-generated profile, based on publicly available information
Akihiro Ota
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology Ibaraki, Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-0035, Tsukuba, Ibaraki, 305-8568, JAPAN
In this paper, we describe the design and development of a positioning and compensation device for a versatile micro robot. To provide microscopic operations, the versatile micro robot has developed. The robot can move in any direction in the manner of an inchworm. However many positioning errors exist because of an assembling error in the four piezoelectric actuators and two electromagnets. We need an automatic positioning device for more accurate work. Motion compensation is also highly required for more effective work. This robot is very small, so it can easily be set to work with the various devices. The positing device should also be small so that we can carry the device easily and set it up in a narrow working area. In this report, we propose a USB camera based positioning device with special compensation function. In experiments, we succeeded in controlling the robot on an octagonal path with controlling the posture angle freely. When we compensate for the motion, the positioning time becomes 60 % compared to that of no compensation. The design procedure, basic performance and biomedical application are also discussed as an advance in the new field of micro-robotics used in precision regions.
This paper reports a novel system to evaluate angle error of rate-integrating gyroscopes. The system equips with a self-calibratable rotary encoder (SelfA) so that it has enough angle accuracy below 10-4-degree level even in rotation at several tens of degrees per second. Angle errors in such a small level cannot be measured with ordinary rotary tables. Therefore, our system can contribute to characterization of high-performance inertial sensors.
To establish an easy-to-use traceability system for laser vibrometers in vibration acceleration standard, a highly accurate reference standard is required. In this study, we investigated the measurement reliability of a commercial laser vibrometer with an analog demodulator. The results confirmed a large measurement deviation from nominal sensitivity values due to characteristics of the analog demodulator. To reduce such deviation, a high-accuracy digital demodulator, which can be utilized as a reference standard, was developed. The experimental results confirmed the improved measurement accuracy of the developed digital demodulator.