Akihiro Ota

Akihiro Ota

Auto-generated profile, based on publicly available information

Akihiro Ota

National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology Ibaraki, Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-0035, Tsukuba, Ibaraki, 305-8568, JAPAN

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Measurement
Verified
Journal Article
Closed access
WKWataru Kokuyama
Wataru Kokuyama
TWTsukasa Watanabe
Tsukasa Watanabe
HNHideaki Nozato
Hideaki Nozato
AOAkihiro Ota
Akihiro Ota

1 January 2016 in Measurement
Verified
Journal Article
Closed access
HNH. Nozato
H. Nozato
WKW. Kokuyama
W. Kokuyama
AOA. Ota
A. Ota

1 September 2008
Verified
Conference Paper
Closed access
OFOhmi Fuchiwaki
Ohmi Fuchiwaki
TKTakashi Kawai
Takashi Kawai
AOAkihiro Ohta
Akihiro Ohta
DMDaigo Misaki
Daigo Misaki
HAHisayuki Aoyama
Hisayuki Aoyama
In this paper, we describe the design and development of a positioning and compensation device for a versatile micro robot. To provide microscopic operations, the versatile micro robot has developed. The robot can move in any direction in the manner of an inchworm. However many positioning errors exist because of an assembling error in the four piezoelectric actuators and two electromagnets. We need an automatic positioning device for more accurate work. Motion compensation is also highly required for more effective work. This robot is very small, so it can easily be set to work with the various devices. The positing device should also be small so that we can carry the device easily and set it up in a narrow working area. In this report, we propose a USB camera based positioning device with special compensation function. In experiments, we succeeded in controlling the robot on an octagonal path with controlling the posture angle freely. When we compensate for the motion, the positioning time becomes 60 % compared to that of no compensation. The design procedure, basic performance and biomedical application are also discussed as an advance in the new field of micro-robotics used in precision regions.

1 March 2015
Verified
Conference Paper
Closed access
WKWataru Kokuyama
Wataru Kokuyama
TWTsukasa Watanabe
Tsukasa Watanabe
HNHideaki Nozato
Hideaki Nozato
AOAkihiro Ota
Akihiro Ota
This paper reports a novel system to evaluate angle error of rate-integrating gyroscopes. The system equips with a self-calibratable rotary encoder (SelfA) so that it has enough angle accuracy below 10-4-degree level even in rotation at several tens of degrees per second. Angle errors in such a small level cannot be measured with ordinary rotary tables. Therefore, our system can contribute to characterization of high-performance inertial sensors.

15 January 2014 in ACTA IMEKO
Verified
Journal Article
Open access
AOAkihiro Oota
Akihiro Oota
HNHideaki Nozato
Hideaki Nozato
WKWataru Kokuyama
Wataru Kokuyama
YKYoshinori Kobayashi
Yoshinori Kobayashi
OTOsamu Takano
Osamu Takano
NKNaoki Kasai
Naoki Kasai
To establish an easy-to-use traceability system for laser vibrometers in vibration acceleration standard, a highly accurate reference standard is required. In this study, we investigated the measurement reliability of a commercial laser vibrometer with an analog demodulator. The results confirmed a large measurement deviation from nominal sensitivity values due to characteristics of the analog demodulator. To reduce such deviation, a high-accuracy digital demodulator, which can be utilized as a reference standard, was developed. The experimental results confirmed the improved measurement accuracy of the developed digital demodulator.

1 January 2006 in IEEJ Transactions on Sensors and Micromachines
Verified
Journal Article
Closed access
AOAkihiro Oota
Akihiro Oota
TUTakashi Usuda
Takashi Usuda
HAHisayuki Aoyama
Hisayuki Aoyama
SSSojun Sato
Sojun Sato