Bouke Adriaans

Dr. Bouke Adriaans

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2020 in Heart
Verified
Journal Article
Open access
PDF file
SHSam Heuts
Sam Heuts
BABouke Adriaans
Bouke Adriaans
BRBartosz Rylski
Bartosz Rylski
CMCasper Mihl
Casper Mihl
SBSebastiaan C A M Bekkers
Sebastiaan C A M Bekkers
PNPeyman Sardari Nia
Peyman Sardari Nia
Objective: Management of thoracic aortic aneurysms (TAAs) comprises regular diameter follow-up until the indication criterion for prophylactic surgery is reached. However, this approach is unable to predict the majority of acute type A aortic dissections (ATAADs). The current study aims to evaluate the diagnostic accuracy of ascending aortic diameter, length and volume for occurrence of ATAAD. Methods: This two-centre observational cohort study retrospectively screened 477 consecutive patients who presented with ATAAD between 2009 and 2018. Of those, 25 (5.2%) underwent CT angiography (CTA) within 2 years before dissection onset. Aortic diameter, length and volume of these patients (‘pre-ATAAD’) were compared with those of TAA controls (n=75). Receiver operating curve analysis was performed to evaluate the predictive accuracy of the three different measurements. Results: 96% of patients with pre-ATAAD did not meet the surgical diameter threshold of 55 mm before dissection onset. Maximal aortic diameters (45 (40–49) mm vs 46 (44–49) mm, p=0.075) and volume (126 (95–157) cm3 vs 124 (102–136) cm3, p=0.909) were comparable between patients with pre-ATAAD and TAA controls. Conversely, ascending aortic length (84±9 mm vs 90±16 mm, p=0.031) was significantly larger in patients with pre-ATAAD. All three parameters had an area under the curve of >0.800. At the 55 mm cut-off point, the maximal diameter yielded a positive predictive value (PPV) of 20%. While maintaining same specificity levels, measurements of aortic volume and length showed superior diagnostic accuracy (PPV 55% and 70%, respectively). Conclusion: Measurements of aortic volume and length have superior diagnostic accuracy compared with the maximal diameter and could improve the timely identification of patients at risk for ATAAD.

5 July 2019 in European Radiology
Verified
Journal Article
Open access
PDF file
BABouke Adriaans
Bouke Adriaans
JWJoachim E. Wildberger
Joachim E. Wildberger
JWJos J. M. Westenberg
Jos J. M. Westenberg
HLHildo J. Lamb
Hildo J. Lamb
SSSimon Schalla
Simon Schalla
Acute aortic syndromes comprise a group of potentially fatal conditions that result from weakening of the aortic vessel wall. Pre-emptive surgical intervention is currently reserved for patients with severe aortic dilatation, although abundant evidence describes the occurrence of dissection and rupture in aortas with diameters below surgical thresholds. Modern imaging techniques (such as hybrid PET-CT and 4D flow MRI) afford the non-invasive assessment of anatomic, hemodynamic, and molecular features of the aorta, and may provide for a more accurate selection of patients who will benefit from preventative surgical intervention. In the current review, we summarize evidence and considerations regarding predictive aortic imaging and highlight evolving imaging modalities that have shown promise to improve risk assessment for the occurrence of dissection and rupture.

30 June 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
BABouke Adriaans
Bouke Adriaans
JWJos J.M. Westenberg
Jos J.M. Westenberg
YCYvonne J.M. van Cauteren
Yvonne J.M. van Cauteren
SGSuzanne Gerretsen
Suzanne Gerretsen
MEMohammed S.M. Elbaz
Mohammed S.M. Elbaz
SSSimon Schalla
Simon Schalla
Background: The prevalence of valvular aortic stenosis (AS) increases as the population ages. Echocardiographic measurements of peak jet velocity (Vpeak), mean pressure gradient (Pmean), and aortic valve area (AVA) determine AS severity and play a pivotal role in the stratification towards valvular replacement. A multimodality imaging approach might be needed in cases of uncertainty about the actual severity of the stenosis.Purpose: To compare four‐dimensional phase‐contrast magnetic resonance (4D PC‐MR), two‐dimensional (2D) PC‐MR, and transthoracic echocardiography (TTE) for quantification of AS.Study Type: Prospective.Population: Twenty patients with various degrees of AS (69.3 ± 5.0 years).Field Strength/Sequences: 4D PC‐MR and 2D PC‐MR at 3T.Assessment: We compared Vpeak, Pmean, and AVA between TTE, 4D PC‐MR, and 2D PC‐MR. Flow eccentricity was quantified by means of normalized flow displacement, and its influence on the accuracy of TTE measurements was investigated.Statistical Tests: Pearson's correlation, Bland–Altman analysis, paired t‐test, and intraclass correlation coefficient.Results: 4D PC‐MR measured higher Vpeak (r = 0.95, mean difference + 16.4 ± 10.7%, P <0.001), and Pmean (r = 0.92, mean difference + 14.9 ± 16.0%, P = 0.013), but a less critical AVA (r = 0.80, mean difference + 19.9 ± 20.6%, P = 0.002) than TTE. In contrast, unidirectional 2D PC‐MR substantially underestimated AS severity when compared with TTE. Differences in Vpeak between 4D PC‐MR and TTE showed to be strongly correlated with the eccentricity of the flow jet (r = 0.89, P <0.001). Use of 4D PC‐MR improved the concordance between Vpeak and AVA (from 0.68 to 0.87), and between PGmean and AVA (from 0.68 to 0.86).Data Conclusion: 4D PC‐MR improves the concordance between the different AS parameters and could serve as an additional imaging technique next to TTE. Future studies should address the potential value of 4D PC‐MR in patients with discordant echocardiographic parameters.Level of Evidence: 2Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2020;51:472–480.

1 April 2022 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
SHSam Heuts
Sam Heuts
BABouke Adriaans
Bouke Adriaans
MKMichal J. Kawczynski
Michal J. Kawczynski
JDJean H.T. Daemen
Jean H.T. Daemen
ENEhsan Natour
Ehsan Natour
EBElham Bidar
Elham Bidar
The extent of aortic replacement during surgery for acute type A aortic dissection (ATAAD) is an important matter of debate. This meta-analysis aimed to evaluate the short and long term outcomes of a proximal aortic repair (PAR) vs. total arch replacement (TAR) in the treatment of ATAAD. A systematic search of PubMed and Embase was performed. Studies comparing PAR to TAR for ATAAD were included. The primary outcomes were early death and long term actuarial survival at one, five, and 10 years. Random effects models in conjunction with relative risks (RRs) were used for meta-analyses. Nineteen studies were included, comprising 5 744 patients (proximal: n = 4 208; total arch: n = 1 536). PAR was associated with reduced early mortality (10.8% [95% confidence interval (CI) 8.4 - 13.7] vs. 14.0% [95% CI 10.4 - 18.7]; RR 0.73 [95% CI 0.63 - 0.85]) and reduced post-operative renal failure (10.4% [95% CI 7.2 - 14.8] vs. 11.1% [95% CI 6.7 - 17.5]; RR 0.77 [95% CI 0.66 - 0.90]), but there was no difference in stroke (8.0% [95% CI 5.9 - 10.7] vs. 7.3% [95% CI 4.6 - 11.3]; RR 0.87 [95% CI 0.69 - 1.10]). No statistically significant difference was found for survival after one year (83.2% [95% CI 77.5 - 87.7] vs. 78.6% [95% CI 69.7 - 85.5]; RR 1.05 [95% CI 0.99 - 1.11]), which persisted after five years (75.4% [95% CI 71.2 - 79.2] vs. 74.5% [95% CI 64.7 - 82.3]; RR 1.02 [95% CI 0.91 - 1.14]). After 10 years, there was a significant survival benefit for patients who underwent TAR (64.7% [95% CI 61.1 - 68.1] vs. 72.4% [95% CI 67.5 - 76.7]; RR 0.91 [95% CI 0.84 - 0.99]). PAR appears to lead to an improved early mortality rate and a reduced complication rate. In the current meta-analysis, the suggestion of an improved 10 year survival benefit of TAR was found, which should be interpreted in the context of potential confounders such as age at presentation, comorbidities, and haemodynamic stability. In any case, PAR seems to be intuitive in older patients with limited dissections, and in those presenting in less stable conditions.

13 April 2021 in Netherlands Heart Journal
Verified
Journal Article
Open access
PDF file
BABouke Adriaans
Bouke Adriaans
MRM. J. F. G. Ramaekers
M. J. F. G. Ramaekers
SHS. Heuts
S. Heuts
HCH. J. G. M. Crijns
H. J. G. M. Crijns
SBS. C. A. M. Bekkers
S. C. A. M. Bekkers
SSS. Schalla
S. Schalla
Background: Cardiovascular guidelines recommend (bi-)annual computed tomography (CT) or magnetic resonance imaging (MRI) for surveillance of the diameter of thoracic aortic aneurysms (TAAs). However, no previous study has demonstrated the necessity for this approach. The current study aims to provide patient-specific intervals for imaging follow-up of non-syndromic TAAs. Methods: A total of 332 patients with non-syndromic ascending aortic aneurysms were followed over a median period of 6.7 years. Diameters were assessed using all available imaging techniques (echocardiography, CT and MRI). Growth rates were calculated from the differences between the first and last examinations. The diagnostic accuracy of follow-up protocols was calculated as the percentage of subjects requiring pre-emptive surgery in whom timely identification would have occurred. Results: The mean growth rate in our population was 0.2 ± 0.4 mm/year. The highest recorded growth rate was 2.0 mm/year, while 40.6% of patients showed no diameter expansion during follow-up. Females exhibited significantly higher growth rates than men (0.3 ± 0.5 vs 0.2 ± 0.4 mm/year, p = 0.007). Conversely, a bicuspid aortic valve was not associated with more rapid aortic growth. The optimal imaging protocol comprises triennial imaging of aneurysms 40–49 mm in diameter and yearly imaging of those measuring 50–54 mm. This strategy is as accurate as annual follow-up, but reduces the number of imaging examinations by 29.9%. Conclusions: In our population of patients with non-syndromic TAAs, we found aneurysm growth rates to be lower than those previously reported. Yearly imaging does not lead to changes in the management of small aneurysms. Thus, lower imaging frequencies might be a good alternative approach.

13 October 2022 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
GBGeertruida P. Bijvoet
Geertruida P. Bijvoet
HNHedwig M. J. M. Nies
Hedwig M. J. M. Nies
RHRobert J. Holtackers
Robert J. Holtackers
Dominik LinzDominik Linz
Dominik Linz
BABouke Adriaans
Bouke Adriaans
CMCasper Mihl
Casper Mihl
Current studies suggest a correlation between high signal intensity at late gadolinium enhancement cardiac MRI and low voltage areas at electroanatomic mapping when assessing atrial fibrosis. Purpose To provide an overview of existing literature on the association between late gadolinium enhancement (LGE) cardiac MRI and low voltage areas (LVA) obtained with electroanatomic mapping (EAM...