Borut Zalik

Dr. Borut Zalik

Department of Computer Science, University of Maribor, Faculty of Electrical Engineering and Computer Science, Maribor, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DKDomen Kavran
Domen Kavran
Domen MongusDomen Mongus
Domen Mongus
BZBorut Zalik
Borut Zalik
Niko LukačNiko Lukač
Niko Lukač
Multispectral satellite imagery offers a new perspective for spatial modelling, change detection and land cover classification. The increased demand for accurate classification of geographically diverse regions led to advances in object-based methods. A novel spatiotemporal method is presented for object-based land cover classification of satellite imagery using a Graph Neural Network. This paper introduces innovative representation of sequential satellite images as a directed graph by connecting segmented land region through time. The method’s novel modular node classification pipeline utilises the Convolutional Neural Network as a multispectral image feature extraction network, and the Graph Neural Network as a node classification model. To evaluate the performance of the proposed method, we utilised EfficientNetV2-S for feature extraction and the GraphSAGE algorithm with Long Short-Term Memory aggregation for node classification. This innovative application on Sentinel-2 L2A imagery produced complete 4-year intermonthly land cover classification maps for two regions: Graz in Austria, and the region of Portorož, Izola and Koper in Slovenia. The regions were classified with Corine Land Cover classes. In the level 2 classification of the Graz region, the method outperformed the state-of-the-art UNet model, achieving an average F1-score of 0.841 and an accuracy of 0.831, as opposed to UNet’s 0.824 and 0.818, respectively. Similarly, the method demonstrated superior performance over UNet in both regions under the level 1 classification, which contains fewer classes. Individual classes have been classified with accuracies up to 99.17%.

1 February 2021 in Applied Soft Computing
Verified
Journal Article
Open access
SKSimon Kolmanič
Simon Kolmanič
DSDamjan Strnad
Damjan Strnad
ŠKŠtefan Kohek
Štefan Kohek
Bedrich BenesBedrich Benes
Bedrich Benes
PHPeter Hirst
Peter Hirst
BZBorut Zalik
Borut Zalik

25 November 2014 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
SJSimon Juric
Simon Juric
BZBorut Zalik
Borut Zalik
Excessive venipunctures are a significant problem both in emergency rooms and during hospital stays. Near-infrared (NIR) illumination devices improve venipuncture success rate but their usage is limited by their availability and economic cost. The objectives of this study were to develop a low-cost NIR spectroscopy prototype from a standard mobile device, to evaluate its efficacy and acceptance as an educational tool, and in a clinical setting. Through a user-centric design process a prototype device was developed. Its educational efficacy was evaluated through a non-invasive, observational study (20 student clinicians, 25 subjects) and its acceptance was assessed using quantitative and qualitative analysis. A smaller clinical trial was performed by a group of 4 medical professionals over a period of 6 weeks that involved 64 patients. The prototype enables real-time visualization of peripheral veins on a variety of Android-based devices. The prototype was 35.2% more successful in visualizing and locating veins (n = 500 attempts) than the nursing students. The acceptance assessment revealed high perception of usefulness, satisfaction, and ease of use. In the clinical trial, 1.6 (SD 1.3) additional veins per patient were identified compared with the traditional visualization methods. To the best of our knowledge this is the first study that describes the design, feasibility and application of an NIR spectroscopy prototype developed on a standard mobile device.

28 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
JDJurij Dolenšek
Jurij Dolenšek
DŠDenis Špelič
Denis Špelič
MKMaša Skelin Klemen
Maša Skelin Klemen
BZBorut Zalik
Borut Zalik
Marko GosakMarko Gosak
Marko Gosak
ASAndraž Stožer
Andraž Stožer
Beta cells in the pancreatic islets of Langerhans are precise biological sensors for glucose and play a central role in balancing the organism between catabolic and anabolic needs. A hallmark of the beta cell response to glucose are oscillatory changes of membrane potential that are tightly coupled with oscillatory changes in intracellular calcium concentration which, in turn, elicit oscillations of insulin secretion. Both membrane potential and calcium changes spread from one beta cell to the other in a wave-like manner. In order to assess the properties of the abovementioned responses to physiological and pathological stimuli, the main challenge remains how to effectively measure membrane potential and calcium changes at the same time with high spatial and temporal resolution, and also in as many cells as possible. To date, the most wide-spread approach has employed the electrophysiological patch-clamp method to monitor membrane potential changes. Inherently, this technique has many advantages, such as a direct contact with the cell and a high temporal resolution. However, it allows one to assess information from a single cell only. In some instances, this technique has been used in conjunction with CCD camera-based imaging, offering the opportunity to simultaneously monitor membrane potential and calcium changes, but not in the same cells and not with a reliable cellular or subcellular spatial resolution. Recently, a novel family of highly-sensitive membrane potential reporter dyes in combination with high temporal and spatial confocal calcium imaging allows for simultaneously detecting membrane potential and calcium changes in many cells at a time. Since the signals yielded from both types of reporter dyes are inherently noisy, we have developed complex methods of data denoising that permit for visualization and pixel-wise analysis of signals. Combining the experimental approach of high-resolution imaging with the advanced analysis of noisy data enables novel physiological insights and reassessment of current concepts in unprecedented detail.

24 November 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
NUNiko Uremovic
Niko Uremovic
MBMarko Bizjak
Marko Bizjak
PSPrimož Sukič
Primož Sukič
GŠGorazd Štumberger
Gorazd Štumberger
BZBorut Zalik
Borut Zalik
Niko LukačNiko Lukač
Niko Lukač
This paper introduces a new integrated framework for short-term time series forecasting used as decision logic support in Energy Management Systems (EMS). The proposed framework defines data preprocessing, forecast model training, and adaptation techniques. For data preprocessing, Gaussian and Kalman filtering were used in offline learning on historical data and online (real-time) forecasting. Optimal parametrisation for both filters was selected based on the forecast accuracy. Next, a multiple-input, single-output forecast model based on the Long Short-Term Memory (LSTM) neural network was tuned for each device. The forecast horizon is single-step, and chaining of predictions was used for longer horizons. Finally, the best model was adapted to the changes in the time series data. A significant drop was observed in the forecast accuracy on the past data after adapting the model to the new data using a naive approach. Due to this drop, a novel sample rehearsal selection strategy for adaptation of the model is proposed and compared to other different strategies. All the techniques are demonstrated based on the examples of forecasting multivariate time series for different household devices: a water heater, a refrigerator and an HVAC device. The use of data preprocessing improved the forecast accuracy by up to 56% compared to no preprocessing. Moreover, by introducing a sample rehearsal, knowledge retention was improved by up to 76.6% compared to the naive approach, and by up to 62% compared to the random selection of samples.

20 October 2023 in Applied Energy
Verified
Journal Article
Open access
Niko LukačNiko Lukač
Niko Lukač
DMDomen Mongus
Domen Mongus
BZBorut Zalik
Borut Zalik
GŠGorazd Štumberger
Gorazd Štumberger
MBMarko Bizjak
Marko Bizjak