Zhijin Zhang

Prof. Dr. Zhijin Zhang


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
HZHang Zhang
Hang Zhang
SYSong Yue
Song Yue
WZWenhui Zeng
Wenhui Zeng
This paper reviews the application of various advanced anti-icing and de-icing technologies in transmission lines. Introduces the influence of snowing and icing disasters on transmission lines, including a mechanical overload of steel towers, uneven icing or de-icing at different times, Ice-covered conductors galloping and icing flashover of insulators, as well as the icing disasters of transmission lines around the world in recent years. The formation of various icing categories on transmission lines, as well as the effect of meteorological factors, topography, altitude, line direction, suspension height, shape, and electric field on ice-covered transmission lines, are all discussed in this study. The application of various advanced anti/de-icing technologies and their advantages and disadvantages in power transmission lines are summarized. The anti/de-icing of traditional mechanical force, AC/DC short-circuit ice melting, and corona effect is introduced. Torque pendulum and diameter-expanded conductor (DEC) have remarkable anti-icing effects, and the early investment resources are less, the cost is low, and the later maintenance is not needed. In view of some deficiencies of AC and DC ice melting, the current transfer intelligent ice melting device (CTIIMD) can solve the problem well. The gadget has a good effect and high reliability for de-icing conductors in addition to being compact and inexpensive. The application of hydrophobic materials and heating coatings on insulators has a certain anti-icing effect, but the service life needs further research. Optimizing the shed’s construction and arranging several string kinds on the insulators is advisable to prevent icing and the anti-icing flashover effect. In building an insulator, only a different shed layout uses non-consumption energy.

26 December 2006 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Xingliang JiangXingliang Jiang
Xingliang Jiang
SWShaohua Wang
Shaohua Wang
Zhijin ZhangZhijin Zhang
Zhijin Zhang
SXShujiao Xie
Shujiao Xie
YWYan Wang
Yan Wang
Based on the results of experimental investigations performed on the polluted and iced IEC standard suspension insulator strings of 3~21 units, the ac flashover performance and discharge process are discussed in this paper. It is put forward that the icing stress product (ISP), defined as the product of the ice-layer conductivity and the ice layer weight per centimeter of dry arc distance can be taken as a characteristic parameter to indicate the effect of ice accretions and contaminants on the flashover voltage. The flashover stress of an ice-covered insulator string can be expressed as a power function of ISP and has a linear relationship with the length of the insulator string. The partial arc of an iced insulator string is initiated by the breakdown of the air gaps between the tips of icicles and iced insulator surface and the persistence is much longer than that of a polluted insulator string

7 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
HZHang Zhang
Hang Zhang
XZXu Zhang
Xu Zhang
QHQin Hu
Qin Hu
Xingliang JiangXingliang Jiang
Xingliang Jiang
The development and utilization of clean energy is becoming more extensive, and wind power generation is one of the key points of this. Occasionally, wind turbines are faced with various extreme environmental impacts such as icing, lightning strikes and so on. In particular, the icing of wind turbines increases icing–wind loads, and results in a reduced power output. And blades broken down lead to large-area shutdown accidents caused by high-speed rotating, which seriously affects the reliability and equipment safety of wind power generation. Relevant institutions and researchers at home and abroad have carried out a lot of research on this. This paper summarizes the formation and influencing factors of wind turbine icing, the influence of icing on wind power generation, and defense technologies. First, it introduces the formation conditions and mechanisms of icing in wind farm regions and the relationship between meteorological and climatic characteristics and icing, and analyzes the key influence factors on icing. Then, the impact of icing on wind turbines is explained from the aspects of mechanical operation, the power curve, jeopardies and economic benefits. And then the monitoring and safety status of wind turbines icing is analyzed, which involves collecting the relevant research on anti-de-icing in wind power generation, introducing various anti/de-icing technologies, and analyzing the principle of icing defense. Finally, this paper summarizes wind turbine icing and its defense technologies, and puts forward the future research direction based on the existing problems of wind power generation icing.

1 September 2018 in High Voltage
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
XQXinhan Qiao
Xinhan Qiao
YZYi Zhang
Yi Zhang
LTLiang Tian
Liang Tian
DZDongdong Zhang
Dongdong Zhang
XJXingliang Jiang
Xingliang Jiang
Currently, it is founded that under unidirectional wind and certain landform, composite insulators are always fan‐shaped non‐uniformly polluted. In this paper, artificial pollution tests on three types of composite insulators with different shed configurations and under various fan‐shaped non‐uniform pollution conditions were carried out. Then the flashover performances of composite insulators, porcelain insulators and glass insulators were compared. Results indicate that there is a big difference between ac flashover performance of composite insulators under non‐uninform pollution and uninform pollution. The flashover voltage of composite insulator is largely influenced by salt deposit density (SDD), the ratio of SDD of windward side to leeward side (W/L), the occupation ratio of leeward side k and the shed configurations. The relationship between SDD and U 50 still meets negative power function when composite insulator is fan‐shaped non‐uninform polluted. There is a reduction of 17.8–27.6% in the flashover strength when the ratio W/L of SDD decreases from 1/1 to 1/15. The shed configurations of composite insulators have great effects on the flashover performance. Composite insulators always have better withstand property compared to glass and porcelain insulators under either uniform pollution or fan‐shaped non‐uniform pollution.

4 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
TLTian Liang
Tian Liang
ZJZhenglong Jiang
Zhenglong Jiang
Xingliang JiangXingliang Jiang
Xingliang Jiang
JHJianlin Hu
Jianlin Hu
GPGuohui Pang
Guohui Pang
Polymer insulators using silicone rubber materials as sheds and sheaths are widely used in power systems to replace traditional porcelain and glass insulators which are heavy, inconvenient to install, and prone to pollution flashover. However, in recent years, polymer insulators that have been operating in harsh outdoor environments for many years have experienced different degrees of aging. The aging degree and aging products of silicone rubber are the focus of research. Fourier transform infrared spectroscopy (FTIR) is a technical method to analyze the internal molecular bonds and functional groups of materials, and it is often used to study the aging degree and aging products of silicone rubber. In this paper, the aging characteristics of silicone rubber samples in a high altitude area, salt fog environment, and acid environment were studied by FTIR. The results showed that the silicone rubber in a harsh environment, such as strong radiation, salt fog, and acid fog was degraded to some extent, and its main chain was cut off, the degree of polymerization was reduced, and the content of hydrophobic functional groups was reduced. Infrared spectroscopy can be used to analyze the aging phenomenon of polymers.

21 May 2019 in IEEE Access
Verified
Journal Article
Open access
Zhijin ZhangZhijin Zhang
Zhijin Zhang
TLTian Liang
Tian Liang
JXJiang Xingliang
Jiang Xingliang
LCLi Chen
Li Chen
YSYang Shenghuan
Yang Shenghuan
ZYZhang Yi
Zhang Yi
In recent years, some composite insulators operating in coastal foggy areas have showed different levels degradation phenomena. This paper presents several performances and properties of silicone rubber under salt-fog environment with AC voltage. Analysis conducted after salt-fog treatment by techniques such as static contact angle, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), dielectric parameter and flashover voltage show a significant degradation of samples. The absorption peak of the hydrophobic groups (Si-(CH3)2 and Si-CH3) decreased, the surface of the material became rough, and the dielectric and electrical properties were also deteriorated. Due to the thermal effects and impact of high-energy particles, the molecular chains on the surface of silicone rubber were broken, and the smooth surface structure was destroyed, resulting in the formation of hydrophilic chemical bonds and precipitation of inorganic substances. The intrusion of moisture further reduces the dielectric parameters and the electrical strength of the material. In addition, the samples in the salt-fog environment with a greater conductivity are more degraded, indicating that the salt-fog has aggravating effect on the aging of the silicone rubber. Thus, it is recommended to pay attention to the monitoring and examining work of composite insulators operating in a foggy and high humidity environment.