Dr. Jianlin Hu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
TLTian Liang
Tian Liang
ZJZhenglong Jiang
Zhenglong Jiang
Xingliang JiangXingliang Jiang
Xingliang Jiang
JHJianlin Hu
Jianlin Hu
GPGuohui Pang
Guohui Pang
Polymer insulators using silicone rubber materials as sheds and sheaths are widely used in power systems to replace traditional porcelain and glass insulators which are heavy, inconvenient to install, and prone to pollution flashover. However, in recent years, polymer insulators that have been operating in harsh outdoor environments for many years have experienced different degrees of aging. The aging degree and aging products of silicone rubber are the focus of research. Fourier transform infrared spectroscopy (FTIR) is a technical method to analyze the internal molecular bonds and functional groups of materials, and it is often used to study the aging degree and aging products of silicone rubber. In this paper, the aging characteristics of silicone rubber samples in a high altitude area, salt fog environment, and acid environment were studied by FTIR. The results showed that the silicone rubber in a harsh environment, such as strong radiation, salt fog, and acid fog was degraded to some extent, and its main chain was cut off, the degree of polymerization was reduced, and the content of hydrophobic functional groups was reduced. Infrared spectroscopy can be used to analyze the aging phenomenon of polymers.

13 January 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Zhijin ZhangZhijin Zhang
Zhijin Zhang
DZDongdong Zhang
Dongdong Zhang
JYJinwei You
Jinwei You
JZJiayao Zhao
Jiayao Zhao
Xingliang JiangXingliang Jiang
Xingliang Jiang
JHJianlin Hu
Jianlin Hu
In areas with heavy dust or continuous wind in a single direction, fan-shaped nonuniform contamination at the windward and leeward side of the insulator string may affect flashover performance. In this paper, dc pollution flashover tests of insulators under fan-shaped nonuniform pollution were presented, and a comparison of flashover performance among 7-unit suspension insulator strings with four different disk profiles was made. Then, the influence of fan-shaped nonuniform pollution on flashover voltage, arc propagation, and critical leakage distance were investigated. Research results indicate that the insulators with different types were influenced variously on their flashover stress, utilization rate of creepage distance, and critical leakage distance by fan-shaped nonuniform pollution. A reduction in the ratio W/L of windward to leeward side salt deposit density (SDD) from 1/1 to 1/15 gave a median 35% ± 4% decrease in flashover strength. The extrapolation of results for the seven-unit strings suggests that some increment in shed space or structure height of the insulator can be preferable in dc transmission lines where there is fan-shaped nonuniform pollution accumulating at the windward and leeward side of the insulator string.

16 May 2016 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhenyu Li
Zhenyu Li
LLLicheng Li
Licheng Li
Xingliang JiangXingliang Jiang
Xingliang Jiang
JHJianlin Hu
Jianlin Hu
Zhijin ZhangZhijin Zhang
Zhijin Zhang
WZWei Zhang
Wei Zhang
As a non-contact discharge detection method, ultraviolet (UV) imaging can rapidly, directly, and securely detect corona discharges. Therefore, UV imaging has been widely applied to power systems. To study the influences of different factors on UV corona discharge detection, two typical types of UV imagers (DayCor®Superb and CoroCAM®6D) were utilized. Results show that the observation angle has little impact on UV detection if no obstacles block the detection line of sight. Given that different UV imagers have different optimal imager gains, photon numbers under different gains could be calibrated to the values under optimal gains in accordance with the gain correction formula. Photon numbers decrease with the increase in the square of observation distance. Detection results under different observation distances could be corrected to the contrast distance after the detection of electrical equipment. The photon numbers of different UV imager types could be corrected in accordance with the instrumental correction factor. The results of this study can provide references to improve the applications and standardizations of UV imaging technology in corona discharge detection.

20 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Zhijin ZhangZhijin Zhang
Zhijin Zhang
JZJianjie Zhao
Jianjie Zhao
XWXiaodong Wan
Xiaodong Wan
Xingliang JiangXingliang Jiang
Xingliang Jiang
JHJianlin Hu
Jianlin Hu
Composite insulators operate in harsh field environments all year round. Their various properties and states of aging require attention. It is important to study the performance changes of composite insulator sheds after aging to evaluate the life of insulators operating on grids. For this reason, 22 composite insulator sheds from different factories, with different voltage levels and different ages years were selected to conduct mechanical properties testing. The mechanical properties include hardness, tensile strength, and elongation at break, and were investigated by thermogravimetric (TGA) testing, surface morphology, and nuclear magnetic resonance (NMR) characterization. The changes in mechanical properties of high temperature vulcanization (HTV) composite insulator silicone rubber aged in the natural environment were analyzed, including the reasons for these changes. The results showed that the transverse relaxation time T2 of the sample was closely related to its aging state. The more serious the silicone rubber’s aging, the smaller was the T2. The state of the composite insulator can be evaluated by using T2 and aging years simultaneously. With the actual degree of aging in the silicone rubber intensified, its tensile strength and elongation at break generally showed a downward trend.

23 April 2018 in Coatings
Verified
Journal Article
Open access
PDF file
KXKe Xu
Ke Xu
JHJianlin Hu
Jianlin Hu
Xingliang JiangXingliang Jiang
Xingliang Jiang
WMWei Meng
Wei Meng
LBLAN Binhuan
LAN Binhuan
LSLichun Shu
Lichun Shu
The icing of wind blades poses a serious threat to the operation of wind turbines. The application of superhydrophobic coatings on wind blades can serve as a potential anti-icing method. This study presents the findings of simulations of the icing environment of wind blades coated with hydrophobic silicone–acrylate resin in an artificial climate chamber. Artificial icing tests were performed on NACA7715 wind blades with four different silicone–acrylate resin coatings and on uncoated wind blades, with test performed at five different wind speeds and three different angles of attack. Results show that wind blade surfaces with higher hydrophobicity yield better anti-icing performance, and that the ice mass of the wind blades decreases with increasing wind speeds and angles of attack. In addition, variations in ice mass, shape, and distribution on different wind blades indicate that increased hydrophobicity can help limit the areas that are subject to freezing. Hydrophobicity can affect the air cavities of the ice deposited on the wind blades, and surfaces with increased hydrophobicity can lead to lower ice mass and less ice adhesion. In brief, surfaces with higher hydrophobicity demonstrate better anti-icing performance and benefit from active de-icing.

28 May 2015 in Energies
Verified
Journal Article
Open access
PDF file
JHJianlin Hu
Jianlin Hu
XJXingliang Jiang
Xingliang Jiang
FYFanghui Yin
Fanghui Yin
Zhijin ZhangZhijin Zhang
Zhijin Zhang
DC flashover performance of ice-covered composite insulators with a parallel air gap (CI/PAG) is an important technical consideration when such insulators are used to isolate ground wires for the purpose of DC ice-melting. Tests on tension and suspension types of CI/PAG were thus carried out in the artificial climate chamber to investigate their DC icing flashover performance. The influences of parallel air gap, ice thickness, pollution severity and air pressure on DC negative 50% flashover voltage (U50%) of CI/PAG were investigated. Test results show that the parallel air gap affected both the discharge path and U50%. With increasing ice thickness, U50% declined by up to 52%; this effect was more evident when the breakdown occurred in the air gap. The pollution severity affected U50% only when the flashover happened along insulator surface. With a decrease of atmospheric pressure, U50% decreased. U50% and the ratio of air pressure were in a power function relationship with a positive characteristic exponent which was relevant to the discharge path.