Marwan Alshipli

Dr. Marwan Alshipli


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
MAMarwan Alshipli
Marwan Alshipli
NKNorlaili A. Kabir
Norlaili A. Kabir
Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low-and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values; .6, 1, 2,3,4,5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.

5 November 2023 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
MAMarwan Alshipli
Marwan Alshipli
TAThamer Ahmad Altaim
Thamer Ahmad Altaim
MAM.W. Aladailah
M.W. Aladailah
AOAmmar A. Oglat
Ammar A. Oglat
SASamira Ahmed Alsenany
Samira Ahmed Alsenany
RGRiziq Allah Gaowgzeh
Riziq Allah Gaowgzeh

31 October 2023 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MAMarwan Alshipli
Marwan Alshipli
MAM.W. Aladailah
M.W. Aladailah
MMMohammad Marashdeh
Mohammad Marashdeh
AOAmmar A. Oglat
Ammar A. Oglat
HAH. F. Akhdar
H. F. Akhdar
AWAl-Tamimi Walaa
Al-Tamimi Walaa
An evaluation of the gamma-neutron shielding capabilities of polymer nanocomposite materials based on polypropylene and iron nanoparticles is presented in this study. The chemical composition of the materials is (100-x) PP-Fex, (where x = 0.1, 0.3, 0.5, 1, 2 and 5 wt percent). For the proposed polymer samples with photon energies ranging from 30 to 2000 KeV, the mass attenuation coefficient (MAC), a crucial parameter for studying gamma-ray shielding capability, was calculated using the Geant4 Monte Carlo code. Results were compared with those predicted by EpiXS. The values of the Geant4 code and the EpiXS software were both found to be in excellent agreement. Using the mass attenuation coefficient values, we determined the linear attenuation coefficients, electron density, effective atomic number, and half value layer for all the samples. The shielding properties of the polymer samples were also evaluated by estimating both the fast neutron removal cross-section and the mean free path of the fast neutron at energies between 0.25 and 5.5 keV. The study's findings indicate a positive correlation between the Fe nanoparticle content and the gamma-ray shielding performance of PP-Fe polymer samples. Out of the several glasses that were evaluated, it was found that the PP-Fe5 polymer sample demonstrates the highest efficacy in terms of gamma-ray shielding. Moreover, the polymer sample PP-Fe5, which consists of 5 mol% of iron (Fe), exhibits the highest value of ∑R (1.10650 cm-1) and the lowest value of the mean free path for fast neutrons. This indicates that the PP-Fe5 possesses better gamma-neutron shielding efficiency.

30 May 2024 in The Journal of Infection in Developing Countries
Verified
Journal Article
Open access
PDF file
MAMarwan Alshipli
Marwan Alshipli
TAThamer A Altaim
Thamer A Altaim
AOAmmar A. Oglat
Ammar A. Oglat
SASamira Ahmed Alsenany
Samira Ahmed Alsenany
OKOsama Khodrog
Osama Khodrog
RGRiziq Allah Gaowgzeh
Riziq Allah Gaowgzeh
Introduction: Coronavirus 2019 symptoms include coagulopathy and thromboembolic risk. Using one parameter to diagnose coagulopathy has little predictive value. Objective: This study will examine if D-dimer and APTT testing can predict COVID-19 severity and aid triage and manage patients. Methods: 214 COVID-19 patients were enrolled and classified into two categories based on their respiratory manifestations; mild (126 cases) and severe (88 cases). Patient data regarding age, gender, D-Dimer level, and APTT level were collected. When both D-Dimer and APTT levels were abnormal, in this study, the patient was considered to have a coagulation disorder. Indicators of coagulation in the COVID-19 patients were collected and compared between the two groups. Chi-square (χ2) tests were used to determine the significant differences between coagulation disorders in the two groups. Results: Our findings showed that patients with coagulopathies were more likely to belong to the severe group. Within the two groups of patients, the rate of coagulation disorders was as follows: mild = 8.8 % within coagulation disorders, 4.8% within the two Groups; severe = 91.2 % within coagulation disorders, 77.8 % within the two Groups. There was a statistically significant relationship between coagulation disorder and severe COVID-19 patients compared to mild patients (p < 0.05). Conclusions: Coagulation disorders are more likely to occur in severe COVID-19 patients. D-Dimer and APTT tests are significant indicators for predicting COVID-19 severity. Our research found an abnormal pattern of coagulation disorders and COVID-19 severity that should be considered in the COVID-19 treatment protocol.

1 January 2020 in Journal of Medical Ultrasound
Verified
Journal Article
Open access
MAMarwan Alshipli
Marwan Alshipli
MSMohannadAdel Sayah
MohannadAdel Sayah
AOAmmarA Oglat
AmmarA Oglat
J Indian Prosthodont Soc, Official publication of Indian Prosthodontic Society

1 May 2025 in Electronic Journal of General Medicine
Verified
Journal Article
Open access
PDF file
MSMohannad Adel Sayah
Mohannad Adel Sayah
AAAhmed Mostafa Abukonna
Ahmed Mostafa Abukonna
Mohammed Abdalla HusseinMohammed Abdalla Hussein
Mohammed Abdalla Hussein
MAMarwan Alshipli
Marwan Alshipli
IAIbrahim G Abdelrhman
Ibrahim G Abdelrhman
Purpose: The review effort throughout the states was needed by the major concern of increased risk of cancer due to radiation exposure in patients during routine X-ray. This study aims to assess the patient entrance surface dosage during X-ray examinations of the skull and thoraco-lumbar spine. Materials and methods: Using a CALDOSE software tool, the dosage received by 146 individuals was assessed based on many technical criteria, including the source-to-image receptor distance, photon quantity by mill ampere second, and photon energy by kilo volt peak. Results: The average entrance surface air kerma (ESAK) is 0.52 for the skull and 0.77 for the thoracic spine. The typical value of the incident air kerma (INAK) is 0.47 for the skull and 0.58 for the thoracic lumbar region. Conclusions: ESAK and INAK are quite effective for comparing the thoracic spine to the cranium. ESAK and INAK can offer data on dosage reduction that should be utilized in the optimization of skull and thoraco-lumbar X-ray examinations.